Shop All Instrument Calibration Kits, Standards & Reagents

QuantStudio™ 5 10-Dye Spectral Calibration Kit, 384-well (Applied Biosystems™)

This easy-to-use dye calibration kit establishes the pure dye spectra and multicomponent values for FAM™, VIC™, ROX™, TAMRA™, SYBR™ , ABY™, JUN™, MUSTANG PURPLE™, NED™, and Cy®5 dyes on the Applied Biosystems™ QuantStudio™ 5 384-well real-time PCR system.

The QuantStudio™ 5 10-Dye Spectral Calibration Kit contains the following:

• QuantStudio™ 5 Spectral Calibration Plate 1 (FAM™, VIC™, ROX™, TAMRA™, and SYBR™ dyes), 384-well (Cat. No. A26334)
• QuantStudio™ 5 Spectral Calibration Plate 2 (ABY™, JUN™, MUSTANG PURPLE™, NED™, and Cy®5 dyes), 384-well (Cat. No. A26335)

This multiple-dye plate calibration kit enables simultaneous dye calibrations in single plates, significantly reducing the effort and time required for dye calibration. In addition, the formulations of the dyes in Plate 2 improve results with multiplexing by more accurately representing the fluorescent spectra of the respective probes found in your real-time PCR experiments.

StepOnePlus™ Real-Time PCR System Spectral Calibration Kit (96 well) (Applied Biosystems™)

This easy-to-use kit establishes the pure dye spectra and multicomponent values for FAM™/SYBR® Green I, VIC®/JOE™, and NED™/TAMRA™/ROX™ dyes on the StepOnePlus™ Real-Time PCR System.

The Applied Biosystems® StepOnePlus™ Real-Time PCR System Spectral Calibration Kit contains one background plate and two preloaded, 96-well fast optical reaction plates containing seven dye standards.
• 96-well optical reaction plates preloaded with dyes (FAM™/SYBR® Green I, VIC®/JOE™, NED™/TAMRA™/ROX™) are provided for quick and easy calibration of the StepOnePlus™ Real-Time PCR System
• Easy-to-use and provides accurate discrimination of the fluorescence signal of individual dyes in the reaction mixture
• Includes the Passive Reference I dye standard for signal normalization in all real-time and endpoint reactions

Spend Your Time on Research—Not Instrument Calibration
This kit's easy-to-use, preloaded, 96-well optical reaction plates enable users to calibrate the StepOnePlus™ Real-Time PCR System quickly and easily. Insert the reaction plates during system installation, and the system automatically collects the dye standard's spectral information. The system's application algorithm then uses the calibration information to ensure accurate data analysis.

3500/3500xL Sequencing Standards, BigDye™ Terminator v1.1 (Applied Biosystems™)

The BigDye® Terminator v1.1 sequencing standard kit contains four tubes, each of which contains enough DNA of a known 1200 base pair sequence prepared with BigDye® Terminator v1.1 to perform one spectral calibration⁄performance check and⁄or one control sequencing run on the Applied Biosystems® 3500 Series Genetic Analyzer. The DNA contained in the preparation has been lyophilized to maximize stability.

For Research Use Only. Not intended for human or animal therapeutic or diagnostic use.

310 Genetic Analyzer Matrix Standards Kit with Manual and Software, dRhodamine

The kit contains matrix standards for use with dRhodamine sequencing chemistries on the 310 Genetic Analyzer. Includes manual and software.

For Research Use Only. Not for use in diagnostics procedures.

DS-32 Matrix Standard Set [5FAM™, JOE™, NED™ and ROX™ dyes] for the 310 Genetic Analyzer (Applied Biosystems™)

The Matrix Standard Set is used to generate the "multicomponent matrix" required when analyzing DNA fragments on the 310 Genetic Anlayzer. The Data Collection Software for these instruments uses the multicomponent matrix to automatically analyze the five different colored fluorescent dye-labeled samples in a single capillary.

For Research Use Only. Not for use in diagnostics procedures.

7300 Real Time PCR Systems Spectral Calibration Kit (Applied Biosystems™)

This easy-to-use kit establishes the pure dye spectra and multicomponent values for FAM™/SYBR® Green I, VIC®/JOE™, and NED™/TAMRA™/ROX™ dyes on the Applied Biosystems® 7300 Real-Time PCR System. The Applied Biosystems® 7300 Real-Time PCR Systems Spectral Calibration Kit I contains one background plate, one region of interest (ROI) calibration plate, and seven spectral calibration plates with seven separate dye standards.

• 96-well optical reaction plates preloaded with dyes (FAM™/SYBR® Green I, VIC®/JOE™, NED™/TAMRA™/ROX™) enable you to calibrate the 7300 Real-Time PCR System quickly and easily
• Easy-to-use, preloaded spectral calibration plates reduce setup time
• Provides accurate discrimination of the fluorescence signal of individual dyes in the reaction mixture
• Includes the Passive Reference I dye standard for signal normalization in all real-time and endpoint reactions

Spend Your Time on Research, Not Instrument Calibration
This kit is easy-to-use, preloaded, 96-well optical reaction plates enable quick and easy calibration of the 7300 Real-Time PCR System. Insert the reaction plates during system installation, and the system automatically collects the dye standard's spectral information. The system's application algorithm then uses this calibration information to ensure accurate data analysis.

Flow Cytometry Size Calibration Kit (nonfluorescent microspheres) (Invitrogen™)

Our Flow Cytometry Size Calibration Kit has nonfluorescent particle-size calibration standards that provide a simple, accurate way to determine cell sizes by flow cytometry. The kit contains six suspensions of highly uniform polystyrene microspheres with the following diameters: 1.0 µm, 2.0 µm, 4.0 µm, 6.0 µm, 10.0 µm and 15.0 µm. All of the microsphere suspensions are provided in convenient dropper vials.

View additional information for flow cytometry calibration and size reference beads.

TaqMan™ RNase P Instrument Verification Plate for ViiA™ 7 System, 384-well (Applied Biosystems™)

Used to perform verification of your ViiA™7 System with 384 Well Block. Please see your instrument maintenance guide for full instructions on use.

TaqMan™ RNase P Instrument Verification Plate for ViiA™ 7 System, 96-well (for 0.2 mL block) (Applied Biosystems™)

The ViiA™ 7 System 96-Well Instrument Verification RNase P kit is used to validate the performance of the Applied Biosystems® ViiA™ 7 Real-Time PCR Systems with the 96-Well Block.

The ViiA™ 7 System 96-Well Instrument Verification RNase P kit contains a 96-well PCR plate preloaded with the necessary reagents to detect and quantitate genomic copies of the human RNase P gene, a single-copy gene encoding the RNA moiety of the RNase P enzyme. Each well contains preloaded reaction mix (1X TaqMan® Universal PCR Master Mix, RNase P primers, and FAM™ dye-labeled probe) and template.

The ViiA™ 7 System 96-Well Instrument Verification RNase P kit must demonstrate the ability to distinguish between 5,000 and 10,000 genomic equivalents with a 99.7% confidence level for a subsequent sample run in a single well. To ensure accurate results, Applied Biosystems® recommends that the performance of your instrument be verified every six months.

DS-30 GeneScan™ Installation Standard (Applied Biosystems™)

The GeneScan™ Installation Standard DS-30 contains pooled PCR products amplified from microsatellite loci present in CEPH individual 1347. The products are labeled with 6-FAM™, HEX™ and NED™. The kit also contains a tube of GeneScan™ 400 HDTM ROX™ Size Standard.

For Research Use Only. Not for use in diagnostics procedures.

InSpeck™ Green (505/515) Microscope Image Intensity Calibration Kit, 6 µm (Invitrogen™)

The 6.0 µm InSpeck microspheres in this kit have diameters close to those of many stained cells, providing fluorescence microscopists with intensity references for generating calibration curves and evaluating instrument performance. The aqueous suspension of microspheres can be directly applied to the sample for calibrating fluorescence intensities, or they can be mounted separately in an adjacent well or on another slide.

3730/3730xl DNA Analyzer Sequencing Standards, BigDye™ Terminator v1.1 (Applied Biosystems™)

This kit contains four tubes of hsp69 standard sequence used for instrument and spectral calibrations. This material is used with the 3730, and 3730xl DNA Analyzers.

For Research Use Only. Not for use in diagnostics procedures.

Pierce™ HeLa Protein Digest Standard (Thermo Scientific™)

The Thermo Scientific Pierce HeLa Protein Digest Standard is a highly validated mammalian protein digest that may be used as a quality control sample for mass spectrometry (MS) analysis of complex proteomic samples.

Features of HeLa Protein Digest Standard:

Positive control sample—complex mammalian proteome sample protein digest (>15,000 proteins) from the HeLa S3 cell line
Thorough tryptic digestion—prepared using both LysC and trypsin to ensure less than 10% tryptic missed cleavages
Validated peptide quality—less than 10% methionine oxidation and less than 10% lysine carbamylation
Rigorously tested—high-quality, consistent protein digest guaranteed and documented via lot-specific certificates of analysis
Stable—provided in a stable lyophilized format

The protein digest standard is derived from a well-established adenocarcinoma reference HeLa S3 cell line. HeLa S3 cells express over 15,000 proteins with relevant post-translational modifications, making this cell line an ideal standard for complex proteome mass spectrometry applications. The cell lysate has been digested with both LysC and trypsin to minimize tryptic missed cleavages and improve protein sequence coverage. Moreover, unlike other commercially available protein digests for MS, the Pierce HeLa Protein Digest Standard meets stringent quality testing specifications, including peptide quality, digestion efficiency, and lot-to-lot digest uniformity.

Applications:
• Qualitative LC assessment
• LC/MS standardization
• LC/MS method development
• TMT™ Reagent method development

The Pierce HeLa Protein Digest Standard is a lyophilized tryptic peptide mixture that can be used as a quality control standard for liquid chromatography (LC) separation, MS method development and MS performance benchmarking. The digest is specifically formulated for LC/MS experiments and does not contain salts or detergents. Using the digest standard routinely before analysis of complex samples makes it possible to monitor and normalize LC/MS performance between samples and over time.

InSpeck™ Green (505/515) Microscope Image Intensity Calibration Kit, 2.5 µm (Invitrogen™)

The InSpeck™ Green Microscopy Image Intensity Calibration Kit provides microsphere standards that generate a series of well-defined fluorescent intensity levels for constructing calibration curves and evaluating sample brightness. Each kit includes six separate suspensions of 2.5 µm fluorescent microspheres with relative fluorescence intensities of 100%, 30%, 10%, 3%, 1% and 0.3% covering the range of intensities commonly encountered in microscopy applications. Unstained control beads and mounting medium are also supplied. The aqueous suspensions of microspheres may be applied directly to the sample for calibrating fluorescence intensities or mounted separately in an adjacent well or on another slide.

Pierce™ TMT11plex Yeast Digest Standard (Thermo Scientific™)

The Thermo Scientific Pierce TMT11plex Yeast Digest Standard is a lyophilized yeast peptide mixture of four congenic strains labeled with TMT11plex reagents to monitor LC-MS/MS system performance for Tandem Mass Tag (TMT) quantitation.

Pierce TMT11plex Yeast Digest Standard features include:
Convenient—pre-labeled with TMT11plex reagents in a ready-to-use lyophilized format
Highly validated—yeast strains verified for genotype, equimolar mixing of the TMT-labeled strains, and overall protein quantitation using TMT
Diagnostic—excellent QC assay tool for quality assessment of LC and MS instrument status
Quantitative—designed to measure the quantitative precision of the TMT reporter ions for each of the 11 channels

Quantitative proteomic strategies using TMT reagents enable sample multiplexing and precise measurement of protein abundance. However, successful execution of this workflow includes multiple steps that may require optimization, including chromatography, mass spectrometry (MS), and data analysis. A critical parameter for success in this workflow is the ability to consistently detect the TMT fragment ions across the 11 channels of multiplexing. This standard has been specifically designed as a tool to monitor LC-MS/MS system performance for TMT quantitation and MS method optimization and validation.

The Pierce TMT11plex Yeast Digest Standard consists of four congenic strains of Saccharomyces cerevisiae (a parental line, BY4741, and three lines lacking the non-essential proteins Met6, His4, or Ura2) labeled in triplicate (knock-out strains) or duplicate (parental strain) with TMT11-plex label reagents (see figure). The knock-out strains are used in combination with the parental strain to enable comparison of peptide and protein abundance in the deleted and parental strains to monitor system performance for quantitation.

In addition to routine quality control assessment, the standard can also be used as a method development tool to measure the accuracy, precision, and dynamic range of different MS approaches, including optimization of offline fractionation, chromatography, MS acquisition, or data analysis settings.

The multifunctional applications for this standard will allow more reproducible TMT quantitation from day-to-day and experiment-to-experiment.

References:
1. Paulo JA, O'Connell JD, Gygi SP. A Triple Knockout (TKO) Proteomics Standard for Diagnosing Ion Interference in Isobaric Labeling Experiments. J Am Soc Mass Spectrom. 2016 10:1620-5.
2. Yang F, Shen Y, Camp DG 2nd, Smith RD. High-pH reversed-phase chromatography with fraction concatenation for 2D proteomic analysis. Expert Rev Proteomics. 2012 9(2):129-34.
3. Dayon L, Pasquarello C, Hoogland C, Sanchez JC, Scherl A. Combining low- and high-energy tandem mass spectra for optimized peptide quantification with isobaric tags. J Proteomics. 2010 73(4):769-77.
4. Diedrich JK, Pinto AF, Yates JR 3rd. Energy dependence of HCD on peptide fragmentation: stepped collisional energy finds the sweet spot. J Am Soc Mass Spectrom. 2013 24(11):1690-9.
5. Chiva C, Sabidó E. HCD-only fragmentation method balances peptide identification and quantitation of TMT-labeled samples in hybrid linear ion trap/orbitrap mass spectrometers. J Proteomics. 2014 96:263-70.