Shop All Gene-Specific Arrays

TaqMan™ Array Human IL9 Pathway (Applied Biosystems™)

The Applied Biosystems® TaqMan® Array Human IL-9 Pathway 96-well Plate contains 44 assays to IL-9 pathway associated genes and 4 assays to candidate endogenous control genes. All assays are plated in duplicate. Gene Signature Plates are 96-well plates that are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment.

• Affordable: minimum order of three plates; ideal for small, medium or large-sized projects
• Fast delivery: on your bench in days
• Convenient: dried PCR primer and TaqMan® probe sets supplied in a 96- well plate, just add master mix and your sample

Same TaqMan®Assay Quality, New Format
TaqMan® Array Plates contain the same high quality TaqMan® Gene Expression Assays (PCR primers and TaqMan® probe sets) that have been commercially available for years in a convenient, dried, 96-well format. Extensive tests have found no difference in performance between TaqMan®Assays supplied in the traditional liquid format and assays dried into a TaqMan® Array Plate. Figure 1 shows the results of an experiment comparing the linear range of the two formats, where no difference in performance was observed.

Just Add Master Mix and Sample, and Begin Cycling
Ideal for projects such as validation of microarray and RNAi data, and pathway studies, the plates include just the right amount of TaqMan®Assay in each well: enough for one 20 µl reaction. You can order as few as three Gene Signature Plates, making these an affordable option for many laboratories and minimizing the waste of unused individually purchased TaqMan®Assays. Save a significant amount of time setting up your experiments. Just add master mix and sample, and begin cycling. Figure 2 is an example Plate Layout with Gene Symbols and Assay IDs

Plate Map Ensures Proper Data Labeling and Easy Re-Ordering
Each pack of TaqMan® Array Plates is shipped with a CD containing the plate configuration map (see Figure 2) along with the details of each TaqMan®Assay. This information is imported into the real-time PCR instrument to enable proper labeling of experimental data and easy access to Assay ID numbers for simple reordering.

Simple to Use
Each TaqMan® Array Plate well contains a single TaqMan®Assay for one 20 µl reaction. The plates can be stored at room temperature or at 4°C. When you are ready to run your assays, simply add PCR master mix and your cDNA sample, seal the plate, and begin cycling on a real-time PCR instrument.

Compatibility
TaqMan® Array Plates have been optimized for use with TaqMan® Gene Expression Master Mix, but are also compatible with TaqMan® Universal PCR Master Mix. For studies using cultured cells, TaqMan® Array Plates are also compatible (and recommended) with the TaqMan® Gene Expression Cells-to-Ct™ Kit. TaqMan® Array Plates must be run on a real-time PCR instrument with 96-well plate capability. The plates have been validated for use on Applied Biosystems® 7000, 7300, 7500 and 7900HT Fast Real-Time PCR Systems using standard 96-well blocks, standard PCR cycling conditions, and 20 µl reaction volumes.

TaqMan™ OpenArray™ Human Inflammation Panel, QuantStudio™ 12K Flex (Applied Biosystems™)

The TaqMan® OpenArray® Human Inflammation Panel is an efficient, easy-to-use OpenArray® plate for quantitative gene expression analysis of inflammation genes important in drug discovery.

The panel covers 586 genes that have been studied as targets for a range of inflammatory diseases, plus 21 endogenous control genes. The plate is pre-formatted and inventoried, cost-effective, convenient, and easy-to-use, without the need for expensive robotics. Results are reproducible and consistent across samples, studies, and labs—for the same data quality from plate-to-plate and lot-to-lot, even with different operators.

This panel is intended for use with the QuantStudio™ 12K Flex Real-time PCR system which can cycle and image 4 pates simultaneously, providing high-throughput results with ease.

TaqMan™ Array, Human Apoptosis via Death Receptors, Fast 96-well (Applied Biosystems™)

These 96-well plates are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment. The TaqMan® Array Human Apoptosis Through Death Receptors 96-well Plate contains 44 assays to genes associated with death receptor mediated apoptosis and 4 assays to candidate endogenous control genes. All assays are plated in duplicate.

TaqMan™ Array Human ILK Signaling (Applied Biosystems™)

These 96-well plates are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment. The TaqMan® Array Human ILK Signaling 96-well Plate contains 92 assays to genes associated with ILK signaling and 4 assays to candidate endogenous control genes.

TaqMan™ OpenArray™ Human Stem Cell Panel, QuantStudio™ 12K Flex (Applied Biosystems™)

The TaqMan® OpenArray® Human Stem Cell Panel is an efficient, easy-to-use OpenArray® plate for the characterization of undifferentiated stem cells or their differentiated derivatives. This gene signature panel targets 609 well-defined genes validated as markers for pluripotency, plus 22 endogenous control genes. The format of the OpenArray® plate allows for 1–4 replicates to be run in parallel per plate.

The TaqMan® OpenArray® Human Stem Cell Panel contains a well-defined set of validated gene expression markers to characterize human embryonic stem (ES) cell identity and assess phenotypic variations between embryonic stem cell isolates. The gene content of this OpenArray® plate resulted directly from the work of the I.S.C.I consortium and characterization of human embryonic stem cell lines by the International Stem Cell Initiative.

The plate is pre-formatted and inventoried, cost-effective, convenient, and easy-to-use, without the need for expensive robotics. Results are reproducible and consistent across samples, studies, and labs—for the same data quality from plate-to-plate and lot-to-lot, even with different operators.

The Right Targets
This OpenArray® plate uses the proprietary Applied Biosystems® OpenArray® technology to simultaneously analyze gene expression levels by quantitative PCR for 609 test genes and 22 endogenous controls.

Genes were included based on the following criteria:

• Expression in human embryonal carcinoma cells (hEC), primordial germ cells, or human ES (hES) cells
• Known role in maintenance of pluripotency in hES cells
• Identification in microplate-based experiments as being correlated with the stem cell state
• Expression known to be characteristic of specific differentiation lineages in the post implantation embryo and mature tissues

This panel is intended for use with the QuantStudio™ 12K Flex Real-time PCR system which can cycle and image 4 pates simultaneously, providing high-throughput results with ease.

TaqMan™ Array, Human Apoptosis Pathways Caused by HIV1, Fast 96-well (Applied Biosystems™)

These 96-well plates are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment. The TaqMan® Array Human Apoptotic Pathways Triggered By HIV1 96-well Plate contains 44 assays to Apoptotic Pathways Triggered By HIV1 associated genes and 4 assays to candidate endogenous control genes. All assays are plated in duplicate.

TaqMan™ Array Human iNOS Signaling (Applied Biosystems™)

The Applied Biosystems® TaqMan® Array Human iNOS Signaling 96-well Plate contains 44 assays to iNOS Signaling associated genes and 4 assays to candidate endogenous control genes. All assays are plated in duplicate. Gene Signature Plates are 96-well plates that are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment.

• Affordable; minimum order of three plates; ideal for small, medium or large-sized projects
• Fast delivery; on your bench in days
• Convenient; dried PCR primer and TaqMan® probe sets supplied in a 96- well plate; just add master mix and your sample
• Same TaqMan®Assay Quality, New Format

TaqMan® Array Plates contain the same high quality TaqMan® Gene Expression Assays (PCR primers and TaqMan® probe sets) that have been commercially available for years in a convenient, dried, 96-well format. Extensive tests have found no difference in performance between TaqMan®Assays supplied in the traditional liquid format and assays dried into a TaqMan® Array Plate. Figure 1 shows the results of an experiment comparing the linear range of the two formats, where no difference in performance was observed.

Just Add Master Mix and Sample, and Begin Cycling
Ideal for projects such as validation of microarray and RNAi data, and pathway studies, the plates include just the right amount of TaqMan®Assay in each well: enough for one 20 µl reaction. You can order as few as three Gene Signature Plates, making these an affordable option for many laboratories and minimizing the waste of unused individually purchased TaqMan®Assays. Save a significant amount of time setting up your experiments. Just add master mix and sample, and begin cycling.

Figure 2 is an example Plate Layout with Gene Symbols and Assay IDs

Plate Map Ensures Proper Data Labeling and Easy Re-Ordering
Each pack of TaqMan® Array Plates is shipped with a CD containing the plate configuration map (see Figure 2) along with the details of each TaqMan®Assay. This information is imported into the real-time PCR instrument to enable proper labeling of experimental data and easy access to Assay ID numbers for simple reordering.

Simple to Use
Each TaqMan® Array Plate well contains a single TaqMan®Assay for one 20 µl reaction. The plates can be stored at room temperature or at 4°C. When you are ready to run your assays, simply add PCR master mix and your cDNA sample, seal the plate, and begin cycling on a real-time PCR instrument.

Compatibility
TaqMan® Array Plates have been optimized for use with TaqMan® Gene Expression Master Mix, but are also compatible with TaqMan® Universal PCR Master Mix. For studies using cultured cells, TaqMan® Array Plates are also compatible (and recommended) with the TaqMan® Gene Expression Cells-to-Ct™ Kit. TaqMan® Array Plates must be run on a real-time PCR instrument with 96-well plate capability. The plates have been validated for use on Applied Biosystems® 7000, 7300, 7500 and 7900HT Fast Real-Time PCR Systems using standard 96-well blocks, standard PCR cycling conditions, and 20 µl reaction volumes.

TaqMan™ Array Human Inflammation Panel (Applied Biosystems™)

The Applied Biosystems® TaqMan® Human Inflammation Array is an efficient, easy-to-use micro fluidic card for quantitative gene expression analysis of inflammation genes important in drug discovery. This product is designed with 96 TaqMan® Gene Expression Assays arrayed in 384 wells and is compatible with an upgraded Applied Biosystems 7900HT Fast Real-Time PCR System and is sold in packs of 4.

The TaqMan® Gene Signature Arrays for human inflammation contain over 90 genes that are, or have been, studied as targets for a range of inflammatory diseases. The array is pre-formatted and inventoried, cost-effective, convenient and easy to use without needing expensive robotics. Results are reproducible and consistent across samples, studies, and labs —the same data quality from card-to-card and lot-to-lot — even with different operators.

TaqMan™ Array, Human PI3K Signaling, Fast 96-well (Applied Biosystems™)

These 96-well plates are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment. The TaqMan® Array Human PI3K Signaling 96-well Plate contains 92 assays to genes associated with PI3K signaling and 4 assays to candidate endogenous control genes.

TaqMan™ OpenArray™ Human Cancer Panel, QuantStudio™ 12K Flex (Applied Biosystems™)

The TaqMan® OpenArray® Human Cancer Panel is an efficient, easy-to-use OpenArray® plate for the characterization of undifferentiated cancers or their differentiated derivatives. This gene signature panel targets 624 well-defined genes validated as markers for pluripotency, plus 24 endogenous control genes. The format of the OpenArray® plate allows for 1–4 replicates to be run in parallel per plate.

The TaqMan® OpenArray® Human Cancer Panel targets genes related to DNA repair, angiogenesis, cell adhesion, and ECM, as well as genes involved in the cell cycle and apoptosis, and many of the genes encoding kinases and transcription factors that have been found to be differentially expressed in early cancer and metastatic disease. In addition, 24 endogenous control genes are included against which the assays can be normalized. All assays in this panel were developed using a high level of bioinformatics and wet-lab stringency.

The plate is pre-formatted and inventoried, cost-effective, convenient, and easy-to-use, without the need for expensive robotics. Results are reproducible and consistent across samples, studies, and labs—for the same data quality from plate-to-plate and lot-to-lot, even with different operators.

This panel is intended for use with the QuantStudio™ 12K Flex Real-time PCR system which can cycle and image 4 pates simultaneously, providing high-throughput results with ease.

TaqMan™ Array, Human Pancreatic Adenocarcinoma, Fast 96-well (Applied Biosystems™)

These 96-well plates are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment. The TaqMan® Array Human Pancreatic Adenocarinoma 96-well Plate contains 92 assays to pancreatic adenocarinoma associated genes and 4 assays to candidate endogenous control genes.

TaqMan™ Array Human Transcription of tRNA (Applied Biosystems™)

The Applied Biosystems® TaqMan® Array Human Transcription of tRNA 96-well Plate contains 28 assays to transcription of tRNA associated genes and 4 assays to candidate endogenous control genes. All assays are plated in triplicate. Gene Signature Plates are 96-well plates that are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment.

• Affordable; minimum order of three plates; ideal for small, medium or large-sized projects
• Fast delivery; on your bench in days
• Convenient; dried PCR primer and TaqMan® probe sets supplied in a 96- well plate; just add master mix and your sample
• Same TaqMan®Assay Quality, New Format

TaqMan® Array Plates contain the same high quality TaqMan® Gene Expression Assays (PCR primers and TaqMan® probe sets) that have been commercially available for years in a convenient, dried, 96-well format. Extensive tests have found no difference in performance between TaqMan®Assays supplied in the traditional liquid format and assays dried into a TaqMan® Array Plate. Figure 1 shows the results of an experiment comparing the linear range of the two formats, where no difference in performance was observed.

Just Add Master Mix and Sample, and Begin Cycling
Ideal for projects such as validation of microarray and RNAi data, and pathway studies, the plates include just the right amount of TaqMan®Assay in each well: enough for one 20 µl reaction. You can order as few as three Gene Signature Plates, making these an affordable option for many laboratories and minimizing the waste of unused individually purchased TaqMan®Assays. Save a significant amount of time setting up your experiments. Just add master mix and sample, and begin cycling.

Figure 2 is an example Plate Layout with Gene Symbols and Assay IDs

Plate Map Ensures Proper Data Labeling and Easy Re-Ordering
Each pack of TaqMan® Array Plates is shipped with a CD containing the plate configuration map (see Figure 2) along with the details of each TaqMan®Assay. This information is imported into the real-time PCR instrument to enable proper labeling of experimental data and easy access to Assay ID numbers for simple reordering.

Simple to Use
Each TaqMan® Array Plate well contains a single TaqMan®Assay for one 20 µl reaction. The plates can be stored at room temperature or at 4°C. When you are ready to run your assays, simply add PCR master mix and your cDNA sample, seal the plate, and begin cycling on a real-time PCR instrument.

Compatibility
TaqMan® Array Plates have been optimized for use with TaqMan® Gene Expression Master Mix, but are also compatible with TaqMan® Universal PCR Master Mix. For studies using cultured cells, TaqMan® Array Plates are also compatible (and recommended) with the TaqMan® Gene Expression Cells-to-Ct™ Kit. TaqMan® Array Plates must be run on a real-time PCR instrument with 96-well plate capability. The plates have been validated for use on Applied Biosystems® 7000, 7300, 7500 and 7900HT Fast Real-Time PCR Systems using standard 96-well blocks, standard PCR cycling conditions, and 20 µl reaction volumes.

TaqMan™ Array, Human IL-4 Pathway, Fast 96-well (Applied Biosystems™)

These 96-well plates are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment. The TaqMan® Array Human IL-4 Pathway 96-well Plate contains 44 assays to genes associated with IL-4 pathways and 4 assays to candidate endogenous control genes. All assays are plated in duplicate.

TaqMan™ Array, Mouse ABC Transporters, Fast 96-well (Applied Biosystems™)

These 96-well plates are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment. The TaqMan® Array Mouse ABC Transporters 96-well Plate contains 44 assays to ABC transporter associated genes and 4 assays to candidate endogenous control genes. All assays are plated in duplicate.

TaqMan™ Array Human Insulin Receptor Pathway (Applied Biosystems™)

These 96-well plates are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment. The TaqMan® Array Human Insulin Receptor Pathway 96-well Plate contains 92 assays to genes associated with Insulin Receptor pathways and 4 assays to candidate endogenous control genes.