Pierce™ BCA Protein Assay Kit - Reducing Agent Compatible (Thermo Scientific™)

This BCA Protein Assay Kit is the reducing agent-compatible version of our popular Thermo Scientific Pierce BCA Protein Assay. The kit enables you to measure protein concentration in samples that contain thiol-reductants dithiothreitol (DTT) and 2-mercaptoethanol (BME).

Features of the BCA Protein Assay Kit—Reducing Agent Compatible:

Compatible—assay samples that contain up to 5 mM DTT, 35 mM BME, or 10 mM TCEP
BCA technology—only a slight modification of the standard BCA Protein Assay protocol (15-minute incubation with Compatibility Reagent); no precipitation steps required
Small samples—requires only 25 µL (standard kit) or less than 10 µL (microplate kit) of sample
Colorimetric—measure with a standard spectrophotometer or plate reader (562nm)
Excellent uniformity—exhibits less protein-to-protein variation than dye-binding methods
High linearity—linear working range for BSA equals 125 to 2000 µg/mL

The BCA Protein Assay Kit—Reducing Agent Compatible (BCA-RAC) provides all of the advantages of the original BCA Assay, plus compatibility with disulfide reducing agents at concentrations routinely used in protein sample buffers. This special adaptation of the popular Pierce BCA Protein Assay method enables accurate protein concentration measurement for samples containing DTT, 2-ME or TCEP. This reducing agent compatible (RAC) BCA Kit extends the already broad reagent compatibility of the BCA Protein Assay protocol to include nearly all types of components commonly present in protein research samples.

Related Products
Pierce™ Microplate BCA Protein Assay Kit - Reducing Agent Compatible
96-Well Plates for Pierce™ BCA-RAC Assay

Pierce™ Microplate BCA Protein Assay Kit - Reducing Agent Compatible (Thermo Scientific™)

This BCA Protein Assay Kit is the reducing agent-compatible version of our popular Thermo Scientific Pierce BCA Protein Assay. The kit enables you to measure protein concentration in samples that contain thiol-reductants dithiothreitol (DTT) and 2-mercaptoethanol (BME), and comes with 20 96-well microplates.

Features of the Microplate BCA Protein Assay Kit—Reducing Agent Compatible:

Compatible—assay samples that contain up to 5 mM DTT, 35 mM BME, or 10 mM TCEP
BCA technology—only a slight modification of the standard BCA Protein Assay protocol (15-minute incubation with Compatibility Reagent); no precipitation steps required
Small samples—requires only 25 µL (standard kit) or less than 10 µL (microplate kit) of sample
Colorimetric—measure with a standard spectrophotometer or plate reader (562nm)
Excellent uniformity—exhibits less protein-to-protein variation than dye-binding methods
High linearity—linear working range for BSA equals 125 to 2000 µg/mL

The BCA Protein Assay Kit—Reducing Agent Compatible (BCA-RAC) provides all of the advantages of the original BCA Assay, plus compatibility with disulfide reducing agents at concentrations routinely used in protein sample buffers. This special adaptation of the popular Pierce BCA Protein Assay method enables accurate protein concentration measurement for samples containing DTT, 2-ME or TCEP. This reducing agent compatible (RAC) BCA Kit extends the already broad reagent compatibility of the BCA Protein Assay protocol to include nearly all types of components commonly present in protein research samples.

Related Products
Pierce™ BCA Protein Assay Kit - Reducing Agent Compatible
96-Well Plates for Pierce™ BCA-RAC Assay
Ampule Breakers

Easy-Titer™ Human IgM Assay Kit (Thermo Scientific™)

The Thermo Scientific Easy-Titer Human IgM Assay Kit includes antibody-sensitized microspheres to measure the specific concentration of antibodies by an easy and rapid microagglutination technique using standard microplates and UV-Vis plate reader (spectrophotometer). This kit is specific for human IgM and, unlike total protein assays, can specifically measure the concentration of target antibody in samples (e.g., serum, plasma, culture supernatant) that contain other proteins. It is sensitive, requiring very small sample volumes. Antibody concentration is determined from the assay response (absorbance) by comparison to a standard curve prepared using dilutions of a known antibody sample (sold separately).

General features of Easy-Titer Antibody Assay Kits:

Antibody-based specificity—measure concentration of target antibody in a sample, not just total protein; no need to purify antibody to assess its concentration
Faster and easier than ELISA—three-component, homogenous assay; 10 minutes total incubation time
No special equipment needed—uses standard vortex mixer, pipetter, 96-well microplate, plate shaker and reader (measure absorbance at 340nm or 400nm)
Sensitive—assay range (standard curve) 8 to 500 ng/mL; use sample at 15 to 300 ng/mL for optimal results
Reproducible—coefficient of variation < 5%; error depends on dilution and pipetting technique
Antibody standards sold separately—see product list for suggested products; use any antibody standard with proper target identity and known concentration (greater than 10 µg/mL)
Kits for five popular targets—choose a kit specific for a particular species and class of immunoglobulin; no cross-reaction with other species and classes of the target antibody

Easy-Titer Assay Kits detect and measure specific target antibodies using agglutination of microspheres that are coated ("sensitized") with the specific anti-IgG or IgM polyclonal antibodies. In the appropriate aqueous buffer (supplied in kit), the monodispersed antibody-coated microspheres (> 1 µM diameter) have highest absorptivity (λ-max) to incident light having a wavelength (340nm) that is equal to approximately half their diameter. When sample is added, two or more microspheres bind to each antibody target via their coated specific polyclonal antibodies, and this agglutination into effectively larger apparent spheres results in proportional decrease in absorptivity (lower absorbance).

Typical microagglutination assays depend on a change in light-scattering and corresponding change in transmittance, to which absorbance is inversely related. Easy-Titer Assay Kits use a special dilution buffer whose refractive index eliminates the effect of light-scattering on the monodispersed microspheres for the measurement wavelength used. Because of this, the final 10- to 20-fold dilution of the sample for use in the assay must be done using the Dilution Buffer supplied in the kit.

Easy-Titer Antibody Assays are faster and easier than ELISA:
• Prepare standards (5 to 500 ng/mL) by diluting purified antibody in Kit Dilution Buffer.
• Prepare samples by diluting in Dilution Buffer to within assay range (8 to 500 ng/mL).
• Vortex vial of microsphere beads to create homogeneous suspension.
• Pipette 20 µL of bead suspension and 20 µL of each sample and standard into 96-well microplate wells.
• Incubate microplate for 5 minutes with vigorous mixing.
• Add 100 µL of Kit Blocking Reagent.
• Incubate microplate for 5 minutes with vigorous mixing.
• Measure absorbance on standard plate reader (340nm or 405nm).
• Plot standard curve and interpolate samples to determine concentration.

Related Products
Easy-Titer™ Mouse IgG Assay Kit
Easy-Titer™ Rabbit IgG Assay Kit
Easy-Titer™ Human IgG (H+L) Assay Kit
Easy-Titer™ Human IgG (gamma chain) Assay Kit

Pierce™ Bovine Gamma Globulin Standard Ampules, 2 mg/mL (Thermo Scientific™)

Thermo Scientific Pierce BGG Protein Assay Standards are high-quality reference samples for generating accurate standard curves and calibration controls in total protein assays.

Features of BGG Protein Assay Standards:

Convenient—1 mL ampules
Antibody standard—best reference standard for immunoglobulin quantitation in colorimetric protein assays
Bradford standard—best general protein standard in coomassie-based (Bradford) protein assays
Pure and stable—supplied in ultrapure 0.9% saline solution with 0.05% sodium azide; room temperature stable
Accurate and consistent—precisely formulated at 2.00 +/-0.03 mg/mL, ensuring excellent lot-to-lot consistency

These bovine gamma globulin (BGG) solutions are protein concentration reference standards for use in BCA, Bradford and other protein assay protocols. BGG is an accepted reference protein for total protein quantitation of purified antibodies or immunoglobulin-rich samples. The IgG standard is precisely formulated at 2 mg/mL in an ultrapure 0.9% sodium chloride (saline) solution. The concentration of the stock solution of purified BGG (Fraction II) is calibrated by direct comparison to an internal standard to ensure lot-to-lot consistency and accuracy.

Applications:
• Protein assay immunoglobulin quantitation standard (Coomassie-Bradford Assay, etc.)
• Antibody recovery control for desalting and other column procedures
• Loading control for SDS-PAGE
• General calibration of spectrophotometer UV-lamp (absorbance at 280nm)

Selection of a protein standard is potentially the greatest source of error in any protein assay. The best choice for an antibody quantitation standard is a purified, known concentration of the specific immunoglobulin being tested. Often this is not available or it is too expensive to use as a standard. In such cases, the best standard is one that will produce a representative color response curve with the selected protein assay and is readily available to any researcher. BGG provides this function for all kinds of immunoglobulin samples, including IgG.

For greatest accuracy in estimating total protein concentration in unknown samples, it is essential to include a standard curve each time the assay is performed. This is particularly true for the protein assay methods that produce non-linear standard curves. Deciding on the number of standards and replicates used to define the standard curve depends upon the degree of non-linearity in the standard curve and the degree of accuracy required. In general, fewer points are needed to construct a standard curve if the color response is linear. Typically, standard curves are constructed using at least two replicates for each point on the curve.

For added safety when opening glass ampules, consider using our Ampule Breakers, which are disposable safety devices that protect the fingers when breaking open a glass ampule.

Related Products
Pierce™ Bovine Gamma Globulin Standard Pre-Diluted Set

Pierce™ Bovine Serum Albumin Standard Pre-Diluted Set (Thermo Scientific™)

Thermo Scientific Pierce BSA Protein Assay Standards are high-quality reference samples for generating accurate standard curves and calibration controls in total protein assays.

Features of BSA Protein Assay Standards:

Convenient—complete set containing seven ready-to-use dilutions
Universal—recognized as the industry standard for protein quantitation in colorimetric protein assays
Pure and stable—supplied in ultrapure 0.9% saline solution with 0.05% sodium azide

These bovine serum albumin (BSA) solutions are protein concentration reference standards for use in BCA, Bradford and other protein assay protocols. BSA is the universally accepted reference protein for total protein quantitation. The set of standards is prepared from a stock solution that is calibrated by direct comparison to purified BSA (Fraction V) from the National Institute of Standards and Technology (NIST).

Applications:
• Protein assay quantitation standard (BCA Protein Assay, Coomassie-Bradford Assay, etc.)
• Protein recovery control for desalting and other column procedures
• General calibration of spectrophotometer UV-lamp (absorbance at 280nm)

Selection of a protein standard is potentially the greatest source of error in any protein assay. The best choice for a standard is a purified, known concentration of the most abundant protein contained in the samples being tested. Often, a highly purified, known concentration of the protein of interest is not available or it is too expensive to use as the standard, or the sample itself is a mixture of many proteins (e.g., cell lysate). In such cases, the best standard is one that will produce a normal (i.e., average) color response curve with the selected protein assay method and is readily available to any researcher. BSA is such a protein, and the Pierce Albumin Standards are the most convenient source of ready-to-use BSA standard.

For greatest accuracy in estimating total protein concentration in unknown samples, it is essential to include a standard curve each time the assay is performed. This is particularly true for the protein assay methods that produce non-linear standard curves. Deciding on the number of standards and replicates used to define the standard curve depends upon the degree of non-linearity in the standard curve and the degree of accuracy required. In general, fewer points are needed to construct a standard curve if the color response is linear. Typically, standard curves are constructed using at least two replicates for each point on the curve.

Related Products
Pierce™ Bovine Serum Albumin Standard Ampules, 2 mg/mL

Qubit™ Protein Assay Kit (Invitrogen™)

The Qubit Protein Assay Kit is designed specifically for use with the Qubit Fluorometer. Using between 1 and 20 µl of your sample, this assay can quantitate samples ranging from 12.5 µg⁄ml to 5 mg⁄ml and exhibits low protein to protein variation. The assay is highly selective for proteins and is designed to be accurate in the presence of reducing reagents, but not in the presence of a large amount of detergent. Common contaminants, such as reducing reagents (DTT, β-mercaptoethanol), salts, free nucleotides, amino acids, solvents, or DNA, but not detergents, are well tolerated in the assay. Slight protocol modifications are required for other contaminants. The kit provides concentrated assay reagent, dilution buffer, and pre-diluted BSA standards. Simply dilute the reagent using the buffer provided, add your sample (any volume between 1 µL and 20 µL is acceptable), and read the concentration.

Which product to choose for fluorometric protein quantitation?
• For 1–20 samples: use this Qubit Protein Assay Kit with the Qubit Fluorometer
• For 20–2000 samples: use the Quant-iT Protein Assay Kit with microplate reader

Notes:
1. All Qubit assay kits can be used with the Qubit 1.0, Qubit 2.0, Qubit 3, and Qubit 4 fluorometers.
2. 500 µL thin-walled PCR tubes are required but not included.

Pierce™ BCA Protein Assay Kit (Thermo Scientific™)

The Thermo Scientific Pierce BCA Protein Assay Kit is a two-component, high-precision, detergent-compatible assay reagent set to measure (A562nm) total protein concentration compared to a protein standard. Used in more labs than any other detergent-compatible protein assay, Pierce BCA Reagents provide accurate determination of protein concentration with most sample types encountered in protein research. The Pierce BCA Assay can be used to assess yields in whole cell lysates and affinity-column fractions, as well as to monitor protein contamination in industrial applications. Compared to most dye-binding methods, the BCA Assay is affected much less by protein compositional differences, providing greater protein-to-protein uniformity.

Features of the BCA Protein Assay Kit:
• Colorimetric—estimate visually or measure with a standard spectrophotometer or plate reader (562nm)
• Excellent uniformity—exhibits less protein-to-protein variation than dye-binding methods
• Compatible—unaffected by typical concentrations of most ionic and nonionic detergents
• Moderately fast—much easier and four times faster than the classical Lowry method
• High linearity—linear working range for BSA equals 20 to 2000 µg/mL
• Sensitive—detect down to 5 µg/mL with the enhanced protocol

Applications:
• Studying protein:protein interactions
• Measuring column fractions after affinity chromatography
• Estimating percent recovery of membrane proteins from cell extracts
• High-throughput screening of fusion proteins

How the BCA Protein Assay Detects Protein:
The BCA Protein Assay combines the well-known reduction of Cu2+ to Cu1+ by protein in an alkaline medium with the highly sensitive and selective colorimetric detection of the cuprous cation (Cu1+) by bicinchoninic acid. The first step is the chelation of copper with protein in an alkaline environment to form a light blue complex. In this reaction, known as the biuret reaction, peptides containing three or more amino acid residues form a colored chelate complex with cupric ions in an alkaline environment containing sodium potassium tartrate.

In the second step of the color development reaction, bicinchoninic acid (BCA) reacts with the reduced (cuprous) cation that was formed in step one. The intense purple-colored reaction product results from the chelation of two molecules of BCA with one cuprous ion. The BCA/copper complex is water-soluble and exhibits a strong linear absorbance at 562 nm with increasing protein concentrations. The BCA reagent is approximately 100 times more sensitive (lower limit of detection) than the pale blue color of the first reaction.

The reaction that leads to BCA color formation is strongly influenced by four amino acid residues (cysteine or cystine, tyrosine, and tryptophan) in the amino acid sequence of the protein. However, unlike the Coomassie dye-binding methods, the universal peptide backbone also contributes to color formation, helping to minimize variability caused by protein compositional differences.

For more information, see the article "Chemistry of Protein Assays" in the Protein Methods Library.

Pierce™ BCA Protein Assay Reagent A (Thermo Scientific™)

BCA Protein Assay Reagent A is a component of the Thermo Scientific Pierce BCA Protein Assay Kit, a two-component, high-precision, detergent-compatible assay reagent set to measure (A562nm) total protein concentration compared to a protein standard.

Used in more labs than any other detergent-compatible protein assay, Pierce BCA Reagents provide accurate determination of protein concentration with most sample types encountered in protein research. The Pierce BCA Assay can be used to assess yields in whole cell lysates and affinity-column fractions, as well as to monitor protein contamination in industrial applications. Compared to most dye-binding methods, the BCA Assay is affected much less by protein compositional differences, providing greater protein-to-protein uniformity.

Features of the Thermo Scientific Pierce BCA Protein Assay Kit (reagents A and B) :

Colorimetric—estimate visually or measure with a standard spectrophotometer or plate reader (562nm)
Excellent uniformity—exhibits less protein-to-protein variation than dye-binding methods
Compatible—unaffected by typical concentrations of most ionic and nonionic detergents
Moderately fast—much easier and four times faster than the classical Lowry method
High linearity—linear working range for BSA equals 20 to 2000 µg/mL
Sensitive—detect down to 5 µg/mL with the enhanced protocol

Applications:
• Studying protein:protein interactions
• Measuring column fractions after affinity chromatography
• Estimating percent recovery of membrane proteins from cell extracts
• High-throughput screening of fusion proteins

How the BCA Protein Assay Detects Protein:
The BCA Protein Assay combines the well-known reduction of Cu2+ to Cu1+ by protein in an alkaline medium with the highly sensitive and selective colorimetric detection of the cuprous cation (Cu1+) by bicinchoninic acid. The first step is the chelation of copper with protein in an alkaline environment to form a light blue complex. In this reaction, known as the biuret reaction, peptides containing three or more amino acid residues form a colored chelate complex with cupric ions in an alkaline environment containing sodium potassium tartrate.

In the second step of the color development reaction, bicinchoninic acid (BCA) reacts with the reduced (cuprous) cation that was formed in step one. The intense purple-colored reaction product results from the chelation of two molecules of BCA with one cuprous ion. The BCA/copper complex is water-soluble and exhibits a strong linear absorbance at 562 nm with increasing protein concentrations. The BCA reagent is approximately 100 times more sensitive (lower limit of detection) than the pale blue color of the first reaction.

The reaction that leads to BCA color formation is strongly influenced by four amino acid residues (cysteine or cystine, tyrosine, and tryptophan) in the amino acid sequence of the protein. However, unlike the Coomassie dye-binding methods, the universal peptide backbone also contributes to color formation, helping to minimize variability caused by protein compositional differences.

For more information, see the article "Chemistry of Protein Assays" in the Protein Methods Library.

Related Products
Pierce™ BCA Protein Assay Kit
Pierce™ BCA Protein Assay Reagent B
Pierce™ BCA Solid

Pierce™ Bovine Gamma Globulin Standard Pre-Diluted Set (Thermo Scientific™)

Thermo Scientific Pierce BGG Protein Assay Standards are high-quality reference samples for generating accurate standard curves and calibration controls in total protein assays.

Features of BGG Protein Assay Standards:

Convenient—complete set containing seven ready-to-use dilutions
Antibody standard—best reference standard for immunoglobulin quantitation in colorimetric protein assays
Bradford standard—best general protein standard in coomassie-based (Bradford) protein assays
Pure and stable—supplied in ultrapure 0.9% saline solution with 0.05% sodium azide; room temperature stable
Accurate and consistent—precisely formulated at 2.00 +/-0.03 mg/mL, ensuring excellent lot-to-lot consistency

These bovine gamma globulin (BGG) solutions are protein concentration reference standards for use in BCA, Bradford and other protein assay protocols. BGG is an accepted reference protein for total protein quantitation of purified antibodies or immunoglobulin-rich samples. The IgG standard is precisely formulated at 2 mg/mL in an ultrapure 0.9% sodium chloride (saline) solution. The concentration of the stock solution of purified BGG (Fraction II) is calibrated by direct comparison to an internal standard to ensure lot-to-lot consistency and accuracy.

Applications:
• Protein assay immunoglobulin quantitation standard (Coomassie-Bradford Assay, etc.)
• Antibody recovery control for desalting and other column procedures
• Loading control for SDS-PAGE
• General calibration of spectrophotometer UV-lamp (absorbance at 280nm)

Selection of a protein standard is potentially the greatest source of error in any protein assay. The best choice for an antibody quantitation standard is a purified, known concentration of the specific immunoglobulin being tested. Often this is not available or it is too expensive to use as a standard. In such cases, the best standard is one that will produce a representative color response curve with the selected protein assay and is readily available to any researcher. BGG provides this function for all kinds of immunoglobulin samples, including IgG.

For greatest accuracy in estimating total protein concentration in unknown samples, it is essential to include a standard curve each time the assay is performed. This is particularly true for the protein assay methods that produce non-linear standard curves. Deciding on the number of standards and replicates used to define the standard curve depends upon the degree of non-linearity in the standard curve and the degree of accuracy required. In general, fewer points are needed to construct a standard curve if the color response is linear. Typically, standard curves are constructed using at least two replicates for each point on the curve.

Related Products
Pierce™ Bovine Gamma Globulin Standard Ampules, 2 mg/mL

Pierce™ Bovine Serum Albumin Standard Ampules, 2 mg/mL (Thermo Scientific™)

Thermo Scientific Pierce BSA Protein Assay Standards are high-quality reference samples for generating accurate standard curves and calibration controls in total protein assays.

Features of BSA Protein Assay Standards:

Convenient—1 mL ampules
Universal—recognized as the industry standard for protein quantitation in colorimetric protein assays
Pure and stable—supplied in ultrapure 0.9% saline solution with 0.05% sodium azide; room temperature stable
Accurate and consistent—precisely formulated at 2.00 +/-0.03 mg/mL compared to an NIST reference

These bovine serum albumin (BSA) solutions are protein concentration reference standards for use in BCA, Bradford and other protein assay protocols. BSA is the universally accepted reference protein for total protein quantitation. The albumin standard is precisely formulated at 2 mg/mL in an ultrapure 0.9% sodium chloride (saline) solution. The concentration of the stock solution is calibrated by direct comparison to purified BSA (Fraction V) from the National Institute of Standards and Technology (NIST).

Applications:
• Protein assay quantitation standard (BCA Protein Assay, Coomassie-Bradford Assay, etc.)
• Protein recovery control for desalting and other column procedures
• General calibration of spectrophotometer UV-lamp (absorbance at 280nm)

Selection of a protein standard is potentially the greatest source of error in any protein assay. The best choice for a standard is a purified, known concentration of the most abundant protein contained in the samples being tested. Often, a highly purified, known concentration of the protein of interest is not available or it is too expensive to use as the standard, or the sample itself is a mixture of many proteins (e.g., cell lysate). In such cases, the best standard is one that will produce a normal (i.e., average) color response curve with the selected protein assay method and is readily available to any researcher. BSA is such a protein, and the Pierce Albumin Standards are the most convenient source of ready-to-use BSA standard.

For greatest accuracy in estimating total protein concentration in unknown samples, it is essential to include a standard curve each time the assay is performed. This is particularly true for the protein assay methods that produce non-linear standard curves. Deciding on the number of standards and replicates used to define the standard curve depends upon the degree of non-linearity in the standard curve and the degree of accuracy required. In general, fewer points are needed to construct a standard curve if the color response is linear. Typically, standard curves are constructed using at least two replicates for each point on the curve.

For added safety when opening glass ampules, consider using our Ampule Breakers, which are disposable safety devices that protect the fingers when breaking open a glass ampule.

Related Products
Pierce™ Bovine Serum Albumin Standard Pre-Diluted Set

Easy-Titer™ Human IgG (H+L) Assay Kit (Thermo Scientific™)

The Thermo Scientific Easy-Titer Human IgG (H+L) Assay Kit includes antibody-sensitized microspheres to measure the specific concentration of antibodies by an easy and rapid microagglutination technique using standard microplates and UV-Vis plate reader (spectrophotometer). This kit is specific for human IgG and, unlike total protein assays, can specifically measure the concentration of target antibody in samples (e.g., serum, plasma, culture supernatant) that contain other proteins. It is sensitive, requiring very small sample volumes. Antibody concentration is determined from the assay response (absorbance) by comparison to a standard curve prepared using dilutions of a known antibody sample (sold separately).

General features of Easy-Titer Antibody Assay Kits:

Antibody-based specificity—measure concentration of target antibody in a sample, not just total protein; no need to purify antibody to assess its concentration
Faster and easier than ELISA—three-component, homogenous assay; 10 minutes total incubation time
No special equipment needed—uses standard vortex mixer, pipetter, 96-well microplate, plate shaker and reader (measure absorbance at 340nm or 400nm)
Sensitive—assay range (standard curve) 8 to 500 ng/mL; use sample at 15 to 300 ng/mL for optimal results
Reproducible—coefficient of variation < 5%; error depends on dilution and pipetting technique
Antibody standards sold separately—see product list for suggested products; use any antibody standard with proper target identity and known concentration (greater than 10 µg/mL)
Kits for five popular targets—choose a kit specific for a particular species and class of immunoglobulin; no cross-reaction with other species and classes of the target antibody

Easy-Titer Assay Kits detect and measure specific target antibodies using agglutination of microspheres that are coated ("sensitized") with the specific anti-IgG or IgM polyclonal antibodies. In the appropriate aqueous buffer (supplied in kit), the monodispersed antibody-coated microspheres (> 1 µM diameter) have highest absorptivity (λ-max) to incident light having a wavelength (340nm) that is equal to approximately half their diameter. When sample is added, two or more microspheres bind to each antibody target via their coated specific polyclonal antibodies, and this agglutination into effectively larger apparent spheres results in proportional decrease in absorptivity (lower absorbance).

Typical microagglutination assays depend on a change in light-scattering and corresponding change in transmittance, to which absorbance is inversely related. Easy-Titer Assay Kits use a special dilution buffer whose refractive index eliminates the effect of light-scattering on the monodispersed microspheres for the measurement wavelength used. Because of this, the final 10- to 20-fold dilution of the sample for use in the assay must be done using the Dilution Buffer supplied in the kit.

Easy-Titer Antibody Assays are faster and easier than ELISA:
• Prepare standards (5 to 500 ng/mL) by diluting purified antibody in Kit Dilution Buffer.
• Prepare samples by diluting in Dilution Buffer to within assay range (8 to 500 ng/mL).
• Vortex vial of microsphere beads to create homogeneous suspension.
• Pipette 20 µL of bead suspension and 20 µL of each sample and standard into 96-well microplate wells.
• Incubate microplate for 5 minutes with vigorous mixing.
• Add 100 µL of Kit Blocking Reagent.
• Incubate microplate for 5 minutes with vigorous mixing.
• Measure absorbance on standard plate reader (340nm or 405nm).
• Plot standard curve and interpolate samples to determine concentration.

Related Products
Easy-Titer™ Mouse IgG Assay Kit
Easy-Titer™ Rabbit IgG Assay Kit
Easy-Titer™ Human IgG (gamma chain) Assay Kit
Easy-Titer™ Human IgM Assay Kit

Compat-Able™ Coomassie Plus Protein Assay Kit (Thermo Scientific™)

The Thermo Scientific Compat-Able Coomassie Plus Protein Assay Kit eliminates interfering substances from protein assay samples to make them compatible with BCA and Bradford assays.

The Compat-Able Reagents remove salts, detergents, reducing agents and other substances from protein samples to eliminate interference with protein assays. The protocol selectively precipitates all of the protein, thereby allowing the non-protein components to be easily decanted and removed. The purified, precipitated protein is redissolved in water, making it ready for accurate determination of the protein concentration by standard protein assay methods. The procedure is accomplished in less than 10 minutes with just a few simple steps. The Compat-Able Preparation Set is available individually or conveniently bundled with either the Thermo Scientific Pierce BCA Protein Assay Kit or the Thermo Scientific Pierce Coomassie Plus Protein Assay Kit.

Features of the Compat-Able Protein Assay Preparation Reagent Kit:

Eliminate incompatibilities—removes nearly any substance that interferes with colorimetric protein assays: salts, detergents, denaturants, reducing agents, and even IEF sample buffer
Simple and fast—prepare samples in less than 10 minutes with four simple steps
Convenient—reagent set is easier to use than homemade TCA or acetone precipitation reagents, thereby producing more consistent results
Scalable—microcentrifuge method is easily scaled to larger centrifuge tube volumes for special needs
Validated—tested and offered together with BCA and Coomassie Plus Protein Assay Kits; protocol integrates control and normalization procedures

Related Products
Compat-Able™ Protein Assay Preparation Reagent Kit
Compat-Able™ BCA Protein Assay Kit
Pierce™ Detergent Compatible Bradford Assay Kit

Easy-Titer™ Human IgG (gamma chain) Assay Kit (Thermo Scientific™)

The Thermo Scientific Easy-Titer Human IgG (gamma chain) Assay Kit includes antibody-sensitized microspheres to measure the specific concentration of antibodies by an easy and rapid microagglutination technique using standard microplates and UV-Vis plate reader (spectrophotometer). This kit is specific for the human IgG gamma chain and, unlike total protein assays, can specifically measure the concentration of target antibody in samples (e.g., serum, plasma, culture supernatant) that contain other proteins. It is sensitive, requiring very small sample volumes. Antibody concentration is determined from the assay response (absorbance) by comparison to a standard curve prepared using dilutions of a known antibody sample (sold separately).

General features of Easy-Titer Antibody Assay Kits:

Antibody-based specificity—measure concentration of target antibody in a sample, not just total protein; no need to purify antibody to assess its concentration
Faster and easier than ELISA—three-component, homogenous assay; 10 minutes total incubation time
No special equipment needed—uses standard vortex mixer, pipetter, 96-well microplate, plate shaker and reader (measure absorbance at 340nm or 400nm)
Sensitive—assay range (standard curve) 8 to 500 ng/mL; use sample at 15 to 300 ng/mL for optimal results
Reproducible—coefficient of variation < 5%; error depends on dilution and pipetting technique
Antibody standards sold separately—see product list for suggested products; use any antibody standard with proper target identity and known concentration (greater than 10 µg/mL)
Kits for five popular targets—choose a kit specific for a particular species and class of immunoglobulin; no cross-reaction with other species and classes of the target antibody

Easy-Titer Assay Kits detect and measure specific target antibodies using agglutination of microspheres that are coated ("sensitized") with the specific anti-IgG or IgM polyclonal antibodies. In the appropriate aqueous buffer (supplied in kit), the monodispersed antibody-coated microspheres (> 1 µM diameter) have highest absorptivity (λ-max) to incident light having a wavelength (340nm) that is equal to approximately half their diameter. When sample is added, two or more microspheres bind to each antibody target via their coated specific polyclonal antibodies, and this agglutination into effectively larger apparent spheres results in proportional decrease in absorptivity (lower absorbance).

Typical microagglutination assays depend on a change in light-scattering and corresponding change in transmittance, to which absorbance is inversely related. Easy-Titer Assay Kits use a special dilution buffer whose refractive index eliminates the effect of light-scattering on the monodispersed microspheres for the measurement wavelength used. Because of this, the final 10- to 20-fold dilution of the sample for use in the assay must be done using the Dilution Buffer supplied in the kit.

Easy-Titer Antibody Assays are faster and easier than ELISA:
• Prepare standards (5 to 500 ng/mL) by diluting purified antibody in Kit Dilution Buffer.
• Prepare samples by diluting in Dilution Buffer to within assay range (8 to 500 ng/mL).
• Vortex vial of microsphere beads to create homogeneous suspension.
• Pipette 20 µL of bead suspension and 20 µL of each sample and standard into 96-well microplate wells.
• Incubate microplate for 5 minutes with vigorous mixing.
• Add 100 µL of Kit Blocking Reagent.
• Incubate microplate for 5 minutes with vigorous mixing.
• Measure absorbance on standard plate reader (340nm or 405nm).
• Plot standard curve and interpolate samples to determine concentration.

Related Products
Easy-Titer™ Mouse IgG Assay Kit
Easy-Titer™ Rabbit IgG Assay Kit
Easy-Titer™ Human IgG (H+L) Assay Kit
Easy-Titer™ Human IgM Assay Kit

ProteinSEQ™ HCP Core Kit (Applied Biosystems™)

The ProteinSEQ™ HCP Core Kit is a customizable kit that enables users to customize their ProteinSEQ host cell protein measurements for their own cell lines. It contains buffers and reagents needed to perform 200 PCR reactions to quantify host cell proteins of any cell line for which there is an antibody available.

Features include:

• Precise—quantitate host cell protein contaminants with excellent precision
• Fast—helps accelerate process development with more valid test results per run
• Efficient—helps reduce hands-on time with less sample dilution and preparation
• Reproducible—achieve unprecedented productivity with 4-log dynamic range

ProteinSEQ CHO HCP quantitation
The ProteinSEQ assay platform uses qPCR technology to measure protein process contaminants with extraordinary sensitivity and unparalleled dynamic range. Host cell protein contaminants from any cell line can be measured easily and effectively by incorporating any anti-HCP antibody into the ProteinSEQ workflow.

Streamlined workflow
The ProteinSEQ HCP Core Kit is the only instrument platform-based HCP quantitation solution to deliver a customizable HCP assay with class-leading sensitivity and 4-log dynamic range. The kit helps accelerate laboratory workflows because the number of sample dilutions and replicates is reduced in each run.

Pierce™ 660nm Protein Assay Kit (Thermo Scientific™)

The Thermo Scientific Pierce 660 nm Protein Assay is a ready-to-use, detergent- and reducing agent-compatible assay reagent to quickly measure (A660 nm) total protein concentration compared to a protein standard.

The Pierce 660 nm Assay is more linear than coomassie-based Bradford assays and compatible with higher concentrations of most detergents, reducing agents and other commonly used reagents. The accessory Ionic Detergent Compatibility Reagent (IDCR) provides for even broader detergent compatibility, making this one of the only protein assays that is suitable for samples containing Laemmli SDS sample buffer with bromophenol blue. Although the Pierce 660 nm Protein Assay produces a higher level of protein-to-protein variation (37%) than other assays, such as the BCA Protein Assay, the simpler single-reagent format and broader substance compatibility make the Pierce 660 nm Assay more convenient for many routine applications. The Pierce 660nm Protein Assay can be performed in either a test tube or microplate format.

Features of the 660 nm Protein Assay Kit:

Versatile—works with a greater range of detergents and reducing agents than other dye-based assays
Fast—single reagent with a simple mix-and-read protocol; no working reagent to prepare
Accurate—produces standard curves that are more linear than with the Bradford assay method
Flexible—assay may be performed in test tubes or microplates
Conserve samples—requires only 10 µL for microplate or 100 µL for the test tube procedures
Convenient—room temperature storage means no waiting for reagent equilibration before use

How the Pierce 660 nm Assay Detects Protein:
The Pierce 660 nm Protein Assay is based on the binding of a proprietary dye-metal complex to protein in acidic conditions that causes a shift in the dye's absorption maximum, which is measured at 660 nm. The dye-metal complex is reddish-brown and changes to green upon protein binding. The color change is produced by deprotonation of the dye at low pH facilitated by interactions with positively charged amino acid groups in proteins. Therefore, the dye interacts mainly with basic residues in proteins, such as histidine, arginine and lysine and to a lesser extent tyrosine, tryptophan and phenylalanine.

The color produced in the assay is stable and increases in proportion to a broad range of increasing protein concentrations, even in the presence of detergents and reducing agents that would be incompatible with Bradford and BCA Protein Assays. The optional IDCR may be added to the assay reagent to increase compatibility with high amounts of ionic detergents, allowing samples containing Laemmli SDS sample buffer with bromophenol blue to be measured. The IDCR completely dissolves by thorough mixing and does not have any effect on the assay.

For more information, see the article "Chemistry of Protein Assays" in the Protein Methods Library.

Related Products
Pierce™ 660nm Protein Assay Reagent
Ionic Detergent Compatibility Reagent for Pierce™ 660nm Protein Assay Reagent