Shop All Protein Quantitation Assay Kits, Reagents & Standards

Easy-Titer™ Rabbit IgG Assay Kit (Thermo Scientific™)

The Thermo Scientific Easy-Titer Rabbit IgG Assay Kit includes antibody-sensitized microspheres to measure the specific concentration of antibodies by an easy and rapid microagglutination technique using standard microplates and UV-Vis plate reader (spectrophotometer). This kit is specific for rabbit IgG and, unlike total protein assays, can specifically measure the concentration of target antibody in samples (e.g., serum, plasma, culture supernatant) that contain other proteins. It is sensitive, requiring very small sample volumes. Antibody concentration is determined from the assay response (absorbance) by comparison to a standard curve prepared using dilutions of a known antibody sample (sold separately).

General features of Easy-Titer Antibody Assay Kits:

Antibody-based specificity—measure concentration of target antibody in a sample, not just total protein; no need to purify antibody to assess its concentration
Faster and easier than ELISA—three-component, homogenous assay; 10 minutes total incubation time
No special equipment needed—uses standard vortex mixer, pipetter, 96-well microplate, plate shaker and reader (measure absorbance at 340nm or 400nm)
Sensitive—assay range (standard curve) 8 to 500 ng/mL; use sample at 15 to 300 ng/mL for optimal results
Reproducible—coefficient of variation < 5%; error depends on dilution and pipetting technique
Antibody standards sold separately—see product list for suggested products; use any antibody standard with proper target identity and known concentration (greater than 10 µg/mL)
Kits for five popular targets—choose a kit specific for a particular species and class of immunoglobulin; no cross-reaction with other species and classes of the target antibody

Easy-Titer Assay Kits detect and measure specific target antibodies using agglutination of microspheres that are coated ("sensitized") with the specific anti-IgG or IgM polyclonal antibodies. In the appropriate aqueous buffer (supplied in kit), the monodispersed antibody-coated microspheres (> 1 µM diameter) have highest absorptivity (λ-max) to incident light having a wavelength (340nm) that is equal to approximately half their diameter. When sample is added, two or more microspheres bind to each antibody target via their coated specific polyclonal antibodies, and this agglutination into effectively larger apparent spheres results in proportional decrease in absorptivity (lower absorbance).

Typical microagglutination assays depend on a change in light-scattering and corresponding change in transmittance, to which absorbance is inversely related. Easy-Titer Assay Kits use a special dilution buffer whose refractive index eliminates the effect of light-scattering on the monodispersed microspheres for the measurement wavelength used. Because of this, the final 10- to 20-fold dilution of the sample for use in the assay must be done using the Dilution Buffer supplied in the kit.

Easy-Titer Antibody Assays are faster and easier than ELISA:
• Prepare standards (5 to 500 ng/mL) by diluting purified antibody in Kit Dilution Buffer.
• Prepare samples by diluting in Dilution Buffer to within assay range (8 to 500 ng/mL).
• Vortex vial of microsphere beads to create homogeneous suspension.
• Pipette 20 µL of bead suspension and 20 µL of each sample and standard into 96-well microplate wells.
• Incubate microplate for 5 minutes with vigorous mixing.
• Add 100 µL of Kit Blocking Reagent.
• Incubate microplate for 5 minutes with vigorous mixing.
• Measure absorbance on standard plate reader (340nm or 405nm).
• Plot standard curve and interpolate samples to determine concentration.

Related Products
Easy-Titer™ Mouse IgG Assay Kit
Easy-Titer™ Human IgG (H+L) Assay Kit
Easy-Titer™ Human IgG (gamma chain) Assay Kit
Easy-Titer™ Human IgM Assay Kit

Pierce™ BCA Solid (Thermo Scientific™)

Thermo Scientific BCA (bicinchonic acid) is for use in BCA protein assays for the determination of protein concentration.

Related Products
Pierce™ BCA Protein Assay Kit
Pierce™ BCA Protein Assay Reagent A
Pierce™ BCA Protein Assay Reagent B

Pierce™ 660nm Protein Assay Kit (Thermo Scientific™)

The Thermo Scientific Pierce 660 nm Protein Assay is a ready-to-use, detergent- and reducing agent-compatible assay reagent to quickly measure (A660 nm) total protein concentration compared to a protein standard.

The Pierce 660 nm Assay is more linear than coomassie-based Bradford assays and compatible with higher concentrations of most detergents, reducing agents and other commonly used reagents. The accessory Ionic Detergent Compatibility Reagent (IDCR) provides for even broader detergent compatibility, making this one of the only protein assays that is suitable for samples containing Laemmli SDS sample buffer with bromophenol blue. Although the Pierce 660 nm Protein Assay produces a higher level of protein-to-protein variation (37%) than other assays, such as the BCA Protein Assay, the simpler single-reagent format and broader substance compatibility make the Pierce 660 nm Assay more convenient for many routine applications. The Pierce 660nm Protein Assay can be performed in either a test tube or microplate format.

Features of the 660 nm Protein Assay Kit:

Versatile—works with a greater range of detergents and reducing agents than other dye-based assays
Fast—single reagent with a simple mix-and-read protocol; no working reagent to prepare
Accurate—produces standard curves that are more linear than with the Bradford assay method
Flexible—assay may be performed in test tubes or microplates
Conserve samples—requires only 10 µL for microplate or 100 µL for the test tube procedures
Convenient—room temperature storage means no waiting for reagent equilibration before use

How the Pierce 660 nm Assay Detects Protein:
The Pierce 660 nm Protein Assay is based on the binding of a proprietary dye-metal complex to protein in acidic conditions that causes a shift in the dye's absorption maximum, which is measured at 660 nm. The dye-metal complex is reddish-brown and changes to green upon protein binding. The color change is produced by deprotonation of the dye at low pH facilitated by interactions with positively charged amino acid groups in proteins. Therefore, the dye interacts mainly with basic residues in proteins, such as histidine, arginine and lysine and to a lesser extent tyrosine, tryptophan and phenylalanine.

The color produced in the assay is stable and increases in proportion to a broad range of increasing protein concentrations, even in the presence of detergents and reducing agents that would be incompatible with Bradford and BCA Protein Assays. The optional IDCR may be added to the assay reagent to increase compatibility with high amounts of ionic detergents, allowing samples containing Laemmli SDS sample buffer with bromophenol blue to be measured. The IDCR completely dissolves by thorough mixing and does not have any effect on the assay.

For more information, see the article "Chemistry of Protein Assays" in the Protein Methods Library.

Related Products
Pierce™ 660nm Protein Assay Reagent
Ionic Detergent Compatibility Reagent for Pierce™ 660nm Protein Assay Reagent

Easy-Titer™ Human IgM Assay Kit (Thermo Scientific™)

The Thermo Scientific Easy-Titer Human IgM Assay Kit includes antibody-sensitized microspheres to measure the specific concentration of antibodies by an easy and rapid microagglutination technique using standard microplates and UV-Vis plate reader (spectrophotometer). This kit is specific for human IgM and, unlike total protein assays, can specifically measure the concentration of target antibody in samples (e.g., serum, plasma, culture supernatant) that contain other proteins. It is sensitive, requiring very small sample volumes. Antibody concentration is determined from the assay response (absorbance) by comparison to a standard curve prepared using dilutions of a known antibody sample (sold separately).

General features of Easy-Titer Antibody Assay Kits:

Antibody-based specificity—measure concentration of target antibody in a sample, not just total protein; no need to purify antibody to assess its concentration
Faster and easier than ELISA—three-component, homogenous assay; 10 minutes total incubation time
No special equipment needed—uses standard vortex mixer, pipetter, 96-well microplate, plate shaker and reader (measure absorbance at 340nm or 400nm)
Sensitive—assay range (standard curve) 8 to 500 ng/mL; use sample at 15 to 300 ng/mL for optimal results
Reproducible—coefficient of variation < 5%; error depends on dilution and pipetting technique
Antibody standards sold separately—see product list for suggested products; use any antibody standard with proper target identity and known concentration (greater than 10 µg/mL)
Kits for five popular targets—choose a kit specific for a particular species and class of immunoglobulin; no cross-reaction with other species and classes of the target antibody

Easy-Titer Assay Kits detect and measure specific target antibodies using agglutination of microspheres that are coated ("sensitized") with the specific anti-IgG or IgM polyclonal antibodies. In the appropriate aqueous buffer (supplied in kit), the monodispersed antibody-coated microspheres (> 1 µM diameter) have highest absorptivity (λ-max) to incident light having a wavelength (340nm) that is equal to approximately half their diameter. When sample is added, two or more microspheres bind to each antibody target via their coated specific polyclonal antibodies, and this agglutination into effectively larger apparent spheres results in proportional decrease in absorptivity (lower absorbance).

Typical microagglutination assays depend on a change in light-scattering and corresponding change in transmittance, to which absorbance is inversely related. Easy-Titer Assay Kits use a special dilution buffer whose refractive index eliminates the effect of light-scattering on the monodispersed microspheres for the measurement wavelength used. Because of this, the final 10- to 20-fold dilution of the sample for use in the assay must be done using the Dilution Buffer supplied in the kit.

Easy-Titer Antibody Assays are faster and easier than ELISA:
• Prepare standards (5 to 500 ng/mL) by diluting purified antibody in Kit Dilution Buffer.
• Prepare samples by diluting in Dilution Buffer to within assay range (8 to 500 ng/mL).
• Vortex vial of microsphere beads to create homogeneous suspension.
• Pipette 20 µL of bead suspension and 20 µL of each sample and standard into 96-well microplate wells.
• Incubate microplate for 5 minutes with vigorous mixing.
• Add 100 µL of Kit Blocking Reagent.
• Incubate microplate for 5 minutes with vigorous mixing.
• Measure absorbance on standard plate reader (340nm or 405nm).
• Plot standard curve and interpolate samples to determine concentration.

Related Products
Easy-Titer™ Mouse IgG Assay Kit
Easy-Titer™ Rabbit IgG Assay Kit
Easy-Titer™ Human IgG (H+L) Assay Kit
Easy-Titer™ Human IgG (gamma chain) Assay Kit

Micro BCA™ Reagent C (MC) (Thermo Scientific™)

Thermo Scientific Micro BCA Reagent C (MC) is a proprietary copper sulfate solution. This product is sufficient for 3200 microplate assays when mixed with Reagents MA and MB.

Related Products
Micro BCA™ Protein Assay Kit
Micro BCA™ Reagent A (MA)
Micro BCA™ Reagent B (MB)

CBQCA Protein Quantitation Kit (Invitrogen™)

The CBQCA Protein Quantitation Kit is a very sensitive assay for quantitating proteins in solution, capable of detection as low as 10 ng of protein per mL. Similar in sensitivity to our NanoOrange protein quantitation reagent (N-6666), CBQCA is better suited for accurate quantitation of proteins in the presence of lipids, membrane fractions or detergents, and for lipoproteins and small peptides.

Pierce™ Coomassie Plus (Bradford) Assay Reagent (Thermo Scientific™)

The Thermo Scientific Pierce Coomassie Plus Protein Assay is a ready-to-use, reducing agent-compatible, improved Bradford assay reagent to quickly measure (A595nm) total protein concentration compared to a protein standard.

The Pierce Coomassie Plus Assay Reagent is a single, ready-to-use solution for measuring protein concentration. Simply add the reagent to equal volumes of samples and standards, mix and then measure the absorbance at 595nm. The assay costs only pennies per sample and can be performed in either test tube or microplate format. The Pierce Coomassie Plus Assay Reagent provides increased linearity of response and only half the protein-to-protein variability of other commercial Bradford assay formulations.

Features of the Coomassie Plus Protein Assay:

Colorimetric—measure with a standard spectrophotometer or plate reader (595nm)
Easy to use—single reagent; no working reagent preparation required
Fast—almost immediate color development; add, mix and read results
Broad range—detects protein concentration in the range 1 to 1500 µg/mL
Better—improved linearity and response-uniformity compared to traditional Bradford formulations
Flexible—microplate and cuvette protocols provided with the instructions and adaptable to several target working ranges

How the Coomassie Plus (Bradford) Assay Detects Protein
Use of coomassie G-250 dye in a colorimetric reagent for the detection and quantitation of total protein was first described by Dr. Marion Bradford in 1976. In the acidic environment of the reagent, protein binds to the coomassie dye. This results in a spectral shift from the reddish/brown form of the dye (absorbance maximum at 465nm) to the blue form of the dye (absorbance maximum at 610nm). The difference between the two forms of the dye is greatest at 595nm, so that is the optimal wavelength to measure the blue color from the coomassie dye-protein complex. If desired, the blue color can be measured at any wavelength between 575nm and 615nm. At the two extremes (575nm and 615nm) there is a loss of about 10% in the measured amount of color (absorbance) compared to that obtained at 595nm.

Development of color in coomassie dye-based (Bradford) protein assays has been associated with the presence of certain basic amino acids (primarily arginine, lysine and histidine) in the protein. Van der Waals forces and hydrophobic interactions also participate in the binding of the dye by protein. The number of Coomassie dye ligands bound to each protein molecule is approximately proportional to the number of positive charges found on the protein. Free amino acids, peptides and low molecular weight proteins do not produce color with coomassie dye reagents. In general, the mass of a peptide or protein must be at least 3,000 daltons to be assayed with this reagent. The assay is performed at room temperature and no special equipment is required. Simply add the sample to the tube containing reagent and the resultant blue color is measured at 595nm following a short room-temperature incubation. The coomassie dye containing protein assay is compatible with most salts, solvents, buffers, thiols, reducing substances and metal chelating agents encountered in protein samples.

For more information, see the article "Chemistry of Protein Assays" in the Protein Methods Library.

Related Products
Pierce™ Coomassie Plus (Bradford) Assay Kit
Pierce™ Detergent Compatible Bradford Assay Kit

ProteinSEQ™ HCP Core Kit (Applied Biosystems™)

The ProteinSEQ™ HCP Core Kit is a customizable kit that enables users to customize their ProteinSEQ host cell protein measurements for their own cell lines. It contains buffers and reagents needed to perform 200 PCR reactions to quantify host cell proteins of any cell line for which there is an antibody available.

Features include:

• Precise—quantitate host cell protein contaminants with excellent precision
• Fast—helps accelerate process development with more valid test results per run
• Efficient—helps reduce hands-on time with less sample dilution and preparation
• Reproducible—achieve unprecedented productivity with 4-log dynamic range

ProteinSEQ CHO HCP quantitation
The ProteinSEQ assay platform uses qPCR technology to measure protein process contaminants with extraordinary sensitivity and unparalleled dynamic range. Host cell protein contaminants from any cell line can be measured easily and effectively by incorporating any anti-HCP antibody into the ProteinSEQ workflow.

Streamlined workflow
The ProteinSEQ HCP Core Kit is the only instrument platform-based HCP quantitation solution to deliver a customizable HCP assay with class-leading sensitivity and 4-log dynamic range. The kit helps accelerate laboratory workflows because the number of sample dilutions and replicates is reduced in each run.

Pierce™ BCA Protein Assay Kit - Reducing Agent Compatible (Thermo Scientific™)

This BCA Protein Assay Kit is the reducing agent-compatible version of our popular Thermo Scientific Pierce BCA Protein Assay. The kit enables you to measure protein concentration in samples that contain thiol-reductants dithiothreitol (DTT) and 2-mercaptoethanol (BME).

Features of the BCA Protein Assay Kit—Reducing Agent Compatible:

Compatible—assay samples that contain up to 5 mM DTT, 35 mM BME, or 10 mM TCEP
BCA technology—only a slight modification of the standard BCA Protein Assay protocol (15-minute incubation with Compatibility Reagent); no precipitation steps required
Small samples—requires only 25 µL (standard kit) or less than 10 µL (microplate kit) of sample
Colorimetric—measure with a standard spectrophotometer or plate reader (562nm)
Excellent uniformity—exhibits less protein-to-protein variation than dye-binding methods
High linearity—linear working range for BSA equals 125 to 2000 µg/mL

The BCA Protein Assay Kit—Reducing Agent Compatible (BCA-RAC) provides all of the advantages of the original BCA Assay, plus compatibility with disulfide reducing agents at concentrations routinely used in protein sample buffers. This special adaptation of the popular Pierce BCA Protein Assay method enables accurate protein concentration measurement for samples containing DTT, 2-ME or TCEP. This reducing agent compatible (RAC) BCA Kit extends the already broad reagent compatibility of the BCA Protein Assay protocol to include nearly all types of components commonly present in protein research samples.

Related Products
Pierce™ Microplate BCA Protein Assay Kit - Reducing Agent Compatible
96-Well Plates for Pierce™ BCA-RAC Assay

Easy-Titer™ Mouse IgG Assay Kit (Thermo Scientific™)

The Thermo Scientific Easy-Titer Mouse IgG Assay Kit includes antibody-sensitized microspheres to measure the specific concentration of antibodies by an easy and rapid microagglutination technique using standard microplates and UV-Vis plate reader (spectrophotometer). This kit is specific for mouse IgG and, unlike total protein assays, can specifically measure the concentration of target antibody in samples (e.g., serum, plasma, culture supernatant) that contain other proteins. It is sensitive, requiring very small sample volumes. Antibody concentration is determined from the assay response (absorbance) by comparison to a standard curve prepared using dilutions of a known antibody sample (sold separately).

General features of Easy-Titer Antibody Assay Kits:

Antibody-based specificity—measure concentration of target antibody in a sample, not just total protein; no need to purify antibody to assess its concentration
Faster and easier than ELISA—three-component, homogenous assay; 10 minutes total incubation time
No special equipment needed—uses standard vortex mixer, pipetter, 96-well microplate, plate shaker and reader (measure absorbance at 340nm or 400nm)
Sensitive—assay range (standard curve) 8 to 500 ng/mL; use sample at 15 to 300 ng/mL for optimal results
Reproducible—coefficient of variation < 5%; error depends on dilution and pipetting technique
Antibody standards sold separately—see product list for suggested products; use any antibody standard with proper target identity and known concentration (greater than 10 µg/mL)
Kits for five popular targets—choose a kit specific for a particular species and class of immunoglobulin; no cross-reaction with other species and classes of the target antibody

Easy-Titer Assay Kits detect and measure specific target antibodies using agglutination of microspheres that are coated ("sensitized") with the specific anti-IgG or IgM polyclonal antibodies. In the appropriate aqueous buffer (supplied in kit), the monodispersed antibody-coated microspheres (> 1 µM diameter) have highest absorptivity (λ-max) to incident light having a wavelength (340nm) that is equal to approximately half their diameter. When sample is added, two or more microspheres bind to each antibody target via their coated specific polyclonal antibodies, and this agglutination into effectively larger apparent spheres results in proportional decrease in absorptivity (lower absorbance).

Typical microagglutination assays depend on a change in light-scattering and corresponding change in transmittance, to which absorbance is inversely related. Easy-Titer Assay Kits use a special dilution buffer whose refractive index eliminates the effect of light-scattering on the monodispersed microspheres for the measurement wavelength used. Because of this, the final 10- to 20-fold dilution of the sample for use in the assay must be done using the Dilution Buffer supplied in the kit.

Easy-Titer Antibody Assays are faster and easier than ELISA:
• Prepare standards (5 to 500 ng/mL) by diluting purified antibody in Kit Dilution Buffer.
• Prepare samples by diluting in Dilution Buffer to within assay range (8 to 500 ng/mL).
• Vortex vial of microsphere beads to create homogeneous suspension.
• Pipette 20 µL of bead suspension and 20 µL of each sample and standard into 96-well microplate wells.
• Incubate microplate for 5 minutes with vigorous mixing.
• Add 100 µL of Kit Blocking Reagent.
• Incubate microplate for 5 minutes with vigorous mixing.
• Measure absorbance on standard plate reader (340nm or 405nm).
• Plot standard curve and interpolate samples to determine concentration.

Related Products
Easy-Titer™ Rabbit IgG Assay Kit
Easy-Titer™ Human IgG (H+L) Assay Kit
Easy-Titer™ Human IgG (gamma chain) Assay Kit
Easy-Titer™ Human IgM Assay Kit

Micro BCA™ Reagent A (MA) (Thermo Scientific™)

Thermo Scientific Pierce Micro BCA Reagent A (MA) is a proprietary alkaline tartrate-carbonate buffer. This product is sufficient for 3200 microplate assays when mixed with Reagents MB and MC.

Related Products
Micro BCA™ Protein Assay Kit
Micro BCA™ Reagent B (MB)
Micro BCA™ Reagent C (MC)

Ionic Detergent Compatibility Reagent for Pierce™ 660nm Protein Assay Reagent (Thermo Scientific™)

The Ionic Detergent Compatibility Reagent is intended for use with the 660 nm Protein Assay reagent (catalog numbers 22662 and 22660). It provides for even broader detergent compatibility, making the 660 nm Protein Assay one of the only protein assays suitable for samples containing Laemmli SDS sample buffer with bromophenol blue. The Ionic Detergent Compatibility Reagent completely dissolves by thorough mixing and does affect the sensitivity of the assay.

Related Products
Pierce™ 660nm Protein Assay Reagent
Pierce™ 660nm Protein Assay Kit

Easy-Titer™ Human IgG (gamma chain) Assay Kit (Thermo Scientific™)

The Thermo Scientific Easy-Titer Human IgG (gamma chain) Assay Kit includes antibody-sensitized microspheres to measure the specific concentration of antibodies by an easy and rapid microagglutination technique using standard microplates and UV-Vis plate reader (spectrophotometer). This kit is specific for the human IgG gamma chain and, unlike total protein assays, can specifically measure the concentration of target antibody in samples (e.g., serum, plasma, culture supernatant) that contain other proteins. It is sensitive, requiring very small sample volumes. Antibody concentration is determined from the assay response (absorbance) by comparison to a standard curve prepared using dilutions of a known antibody sample (sold separately).

General features of Easy-Titer Antibody Assay Kits:

Antibody-based specificity—measure concentration of target antibody in a sample, not just total protein; no need to purify antibody to assess its concentration
Faster and easier than ELISA—three-component, homogenous assay; 10 minutes total incubation time
No special equipment needed—uses standard vortex mixer, pipetter, 96-well microplate, plate shaker and reader (measure absorbance at 340nm or 400nm)
Sensitive—assay range (standard curve) 8 to 500 ng/mL; use sample at 15 to 300 ng/mL for optimal results
Reproducible—coefficient of variation < 5%; error depends on dilution and pipetting technique
Antibody standards sold separately—see product list for suggested products; use any antibody standard with proper target identity and known concentration (greater than 10 µg/mL)
Kits for five popular targets—choose a kit specific for a particular species and class of immunoglobulin; no cross-reaction with other species and classes of the target antibody

Easy-Titer Assay Kits detect and measure specific target antibodies using agglutination of microspheres that are coated ("sensitized") with the specific anti-IgG or IgM polyclonal antibodies. In the appropriate aqueous buffer (supplied in kit), the monodispersed antibody-coated microspheres (> 1 µM diameter) have highest absorptivity (λ-max) to incident light having a wavelength (340nm) that is equal to approximately half their diameter. When sample is added, two or more microspheres bind to each antibody target via their coated specific polyclonal antibodies, and this agglutination into effectively larger apparent spheres results in proportional decrease in absorptivity (lower absorbance).

Typical microagglutination assays depend on a change in light-scattering and corresponding change in transmittance, to which absorbance is inversely related. Easy-Titer Assay Kits use a special dilution buffer whose refractive index eliminates the effect of light-scattering on the monodispersed microspheres for the measurement wavelength used. Because of this, the final 10- to 20-fold dilution of the sample for use in the assay must be done using the Dilution Buffer supplied in the kit.

Easy-Titer Antibody Assays are faster and easier than ELISA:
• Prepare standards (5 to 500 ng/mL) by diluting purified antibody in Kit Dilution Buffer.
• Prepare samples by diluting in Dilution Buffer to within assay range (8 to 500 ng/mL).
• Vortex vial of microsphere beads to create homogeneous suspension.
• Pipette 20 µL of bead suspension and 20 µL of each sample and standard into 96-well microplate wells.
• Incubate microplate for 5 minutes with vigorous mixing.
• Add 100 µL of Kit Blocking Reagent.
• Incubate microplate for 5 minutes with vigorous mixing.
• Measure absorbance on standard plate reader (340nm or 405nm).
• Plot standard curve and interpolate samples to determine concentration.

Related Products
Easy-Titer™ Mouse IgG Assay Kit
Easy-Titer™ Rabbit IgG Assay Kit
Easy-Titer™ Human IgG (H+L) Assay Kit
Easy-Titer™ Human IgM Assay Kit

Micro BCA™ Protein Assay Kit (Thermo Scientific™)

The Thermo Scientific Pierce Micro BCA Protein Assay Kit is a special 3-component version of our popular BCA Reagents, optimized to measure (A562nm) total protein concentration of dilute protein solutions (0.5 to 20 micrograms/mL).

Features of the Micro BCA Protein Assay Kit:

Sensitive—accurately detect down to 0.5 µg/mL (2 µg/mL in microplate format)
High linearity—linear working range for BSA equals 0.5 to 20 µg/mL
Colorimetric—measure with a standard spectrophotometer or plate reader (562nm)
Compatible—unaffected by typical concentrations of most ionic and nonionic detergents
Convenient—microplate and cuvette protocols provided with the instructions
Stable—kit stable at room temperature; prepared working reagent stable for to 24 hours

The Micro BCA Protein Assay Kit is a specialized version of the popular Pierce BCA Protein Assay for determining the protein concentration of dilute samples. Mixing together the three Micro BCA Reagents results in a working solution that is sufficiently concentrated to measure protein when mixed with an equal volume of sample. The result is an assay for accurately measuring 0.5 to 20 µg/mL protein solutions. The assay is exceptionally linear and exhibits very low levels of protein-to-protein variability.

Related Products
Micro BCA™ Reagent A (MA)
Micro BCA™ Reagent B (MB)
Micro BCA™ Reagent C (MC)
Ampule Breakers

Qubit™ Protein Assay Kit (Invitrogen™)

The Qubit Protein Assay Kit is designed specifically for use with the Qubit Fluorometer. Using between 1 and 20 µl of your sample, this assay can quantitate samples ranging from 12.5 µg⁄ml to 5 mg⁄ml and exhibits low protein to protein variation. The assay is highly selective for proteins and is designed to be accurate in the presence of reducing reagents, but not in the presence of a large amount of detergent. Common contaminants, such as reducing reagents (DTT, β-mercaptoethanol), salts, free nucleotides, amino acids, solvents, or DNA, but not detergents, are well tolerated in the assay. Slight protocol modifications are required for other contaminants. The kit provides concentrated assay reagent, dilution buffer, and pre-diluted BSA standards. Simply dilute the reagent using the buffer provided, add your sample (any volume between 1 µL and 20 µL is acceptable), and read the concentration.

Which product to choose for fluorometric protein quantitation?
• For 1–20 samples: use this Qubit Protein Assay Kit with the Qubit Fluorometer
• For 20–2000 samples: use the Quant-iT Protein Assay Kit with microplate reader

Notes:
1. All Qubit assay kits can be used with the Qubit 1.0, Qubit 2.0, Qubit 3, and Qubit 4 fluorometers.
2. 500 µL thin-walled PCR tubes are required but not included.