Shop All Capillaries & Polymers

3130xl/3100 Genetic Analyzer 16-Capillary Array, 22 cm Applied Biosystems™

This is a 22 cm 16-capillary array (internally uncoated) for the 3130xl and 3100 Genetic Analyzer. Use for short fragment analysis. Capillary dimensions are 33 cm x 50 µm i.d. Usage per array is 100 runs.

3130xl/3100 Genetic Analyzer 16-Capillary Array, 50cm Applied Biosystems™

This is a 50 cm 16-capillary array (internally uncoated) for the 3130xl and 3100 Genetic Analyzer. Use for fragment analysis and sequencing applications. Capillary dimensions are 61 cm x 50 µm i.d. Usage per array is 100 runs (with use of Applied Biosystems reagents).

3730 DNA Analyzer 48-Capillary Array, 50 cm Applied Biosystems™

This is a Capillary Array for the Applied Biosystems® 3730 DNA Analyzers. Each array contains 48 capillaries, 50 cm long. Used for sequencing runs.

Usage per array: 300 runs (with use of Applied Biosystems reagents).

3130xl/3100 Genetic Analyzer 16-Capillary Array, 80 cm Applied Biosystems™

This is an 80 cm 16-capillary array (internally uncoated) for the 3130xl and 3100 Genetic Analyzer. Use for long read sequencing. Capillary dimensions are 91 cm x 50 µm i.d. Usage per array is 100 runs.

3130xl/3100 Genetic Analyzer 16-Capillary Array, 36 cm Applied Biosystems™

This is a 36 cm 16-capillary array (internally uncoated) for the 3130xl and 3100 Genetic Analyzer. Use for fragment analysis and rapid sequencing applications. Capillary dimensions are 47 cm x 50 µm i.d. Usage per array is 100 runs (with use of Applied Biosystems reagents).

POP-6™ Polymer for 3500/3500xL Genetic Analyzers Applied Biosystems™

This is a 960-sample pouch of POP-6™ polymer for the 3500⁄3500xl Genetic Analyzer. The POP-6™ separation matrix is optimized for standard sequencing and fragment analysis. POP-4™, POP-6™ and POP-7™ are conveniently offered in easy to use pouch packages with either 960 samples (maximum) or 384 samples (maximum) size formats. Each polymer is optimized for specific applications.
• Easy to Use: Pre-formulated and in a single use pouch, which not only saves time but also ensures reliability and consistency
• Include Radio Frequency Identification (RFID) label: Easy to track important information such as Part⁄Lot number, Samples remaining and expiry dates (displayed on software dashboard)
• Robust Formulation: Formulated for sequencing and fragment analysis applications.
• Replenishable: Allow capillaries to be used multiple times.

Reproducible Results
POP™ polymers dynamically coat the capillary wall to control electro-osmotic flow. Their definite quality and uniform consistency eliminate guesswork and help to ensure reproducibility. POP Polymers are specifically formulated to separate DNA fragments of a known size range at a desired resolution and run time.

Many Choices
POP-7™ polymers are very versatile and designed for a wide range of short read to long read sequencing applications as well as fragment analysis. POP-4™ polymers are designed specifically for HID⁄Forensic applications, while POP-6™ polymers are the choice for certain sequencing applications (and fragment analysis).

For partially used pouches that need to be stored, a cap (4412619) that plugs into the pouch fitment opening is recommended.

For Research Use Only. Not for use in diagnostics procedures.

POP-7™ Polymer for 3730/3730xl DNA Analyzers Applied Biosystems™

POP-7™ Polymer is a separation matrix for the 3730 and 3730xl DNA Analyzers. POP-7™ Polymer is customized for DNA sequencing and fragment analysis. Not suitable for use with ABI PRISM ®, 310 and 3100 series genetic analyzers. It causes syringe failure and premature array degradation. Sufficient for 8,000 - 12,000 samples.

POP-7™ Polymers for the 3730⁄3730xl Genetic Analyzers is:
• Pre-formulated, which not only saves time but also saves reproducibility by ensuring consistent formulation
• Formulated for sequencing and fragment analysis applications
• Designed to allow capillaries to be used multiple times

Reproducible Results
POP™ polymers dynamically coat the capillary wall to control electro-osmotic flow. Their definite quality and uniform consistency eliminate guesswork and help to ensure reproducibility. POP polymers are specifically formulated to separate DNA fragments of a known size range at a desired resolution and run time.

Used With
3730/3730xl Genetic Analyzer Capillary Array, 50 cm, 3730 Running Buffer, 10X, BigDye® Terminator v1.1 Cycle Sequencing Kit, BigDye® Terminator v3.1 Cycle Sequencing Kit, BigDye® Terminator v3.1 Cycle Sequencing Kit, BigDye® Terminator v3.1 Cycle Sequencing Kit, Hi-Di™ Formamide.

For Research Use Only. Not for use in diagnostics procedures.

310 Genetic Analyzer Capillary, 47 cm (36 cm wtr - well to read) Applied Biosystems™

This is an internally uncoated Capillary for the 310 Genetic Analyzer, 47 cm long. Use for genescan and rapid sequencing applications. 100 runs⁄capillary.

Used With
2.5 µL Glass Syringe, 310 Running Buffer (10X), POP-4® Polymer for the 310 Genetic Analyzer, POP-6™ Polymer for the 310 Genetic Analyzer.

For Research Use Only. Not for use in diagnostics procedures.

POP-4™ Polymer for 3500/3500xL Genetic Analyzers Applied Biosystems™

This is a 960-sample pouch of POP-4™ polymer for the 3500⁄3500xl Genetic Analyzer. The POP-4™ separation matrix is optimized for HID⁄forensic applications. POP-4™, POP-6™ and POP-7™ are conveniently offered in easy to use pouch packages with either 960 samples (maximum) or 384 samples (maximum) size formats. Each polymer is optimized for specific applications.
• Easy to Use: Pre-formulated and in a single use pouch, which not only saves time but also ensures reliability and consistency
• Include Radio Frequency Identification (RFID) label: Easy to track important information such as Part⁄Lot number, Samples remaining and expiry dates (displayed on software dashboard)
• Robust Formulation: Formulated for sequencing and fragment analysis applications.
• Replenishable: Allow capillaries to be used multiple times.

Reproducible Results
POP™ polymers dynamically coat the capillary wall to control electro-osmotic flow. Their definite quality and uniform consistency eliminate guesswork and help to ensure reproducibility. POP Polymers are specifically formulated to separate DNA fragments of a known size range at a desired resolution and run time.

Many Choices
POP-7™ polymers are very versatile and designed for a wide range of short read to long read sequencing applications as well as fragment analysis. POP-4™ polymers are designed specifically for HID⁄Forensic applications, while POP-6™ polymers are the choice for certain sequencing applications (and fragment analysis).

For partially used pouches that need to be stored, a cap (4412619) that plugs into the pouch fitment opening is recommended.

For Research Use Only. Not for use in diagnostics procedures.

3500xL Genetic Analyzer 24-Capillary Array, 50 cm Applied Biosystems™

The internally uncoated capillaries are supplied in preassembled sets of 24 capillaries per array, with a built-in frame for easy installation.

Applications of the 50 cm capillaries:
Sequencing fragment analysis and protein quality analysis

For Research Use Only. Not for use in diagnostics procedures.

POP-6™ Polymer for 3130/3130xl Genetic Analyzers Applied Biosystems™

The POP-6™ Polymer is a separation matrix for performing standard and rapid DNA sequencing on the Applied Biosystems 3130 and the Applied Biosystems 3130xl Genetic Analyzers. Usage per bottle: Up to 250 samples.

POP-6™ Polymer is a separation matrix for the 3130⁄3130xl Genetic Analyzers that is:
• Easy to Use: Pre-formulated, which not only saves time but also saves reproducibility by ensuring consistent formulation.
• Robust Formulation: Formulated for sequencing and fragment analysis applications.
• Replenishable: Allow capillaries to be used multiple times.

Reproducible Results
POP-6™ polymer dynamically coats the capillary wall to control electro-osmotic flow. Its definite quality and uniform consistency eliminate guesswork and help to ensure reproducibility. POP-4® Polymer is specifically formulated to separate DNA fragments of a known size range at a desired resolution and run time. For the ABI PRISM® 310 and 3100 Genetic Analyzers POP-6™ polymers are the choice for standard and rapid sequencing. For the ABI PRISM® 3700 DNA Analyzer, POP-6™ polymer is designed for genotyping applications.

Used With
3130 Genetic Analyzer, Hi-Di™ Formamide.

For Research Use Only. Not for use in diagnostics procedures.

POP-7™ Polymer for 3500/3500xL Genetic Analyzers Applied Biosystems™

This is a 384-sample pouch of POP-7™ polymer for the 3500⁄3500xl Genetic Analyzer. The POP-7™ separation matrix is optimized for short- to long-read sequencing and fragment analysis. POP-4™, POP-6™ and POP-7™ are conveniently offered in easy to use pouch packages with either 960 samples (maximum) or 384 samples (maximum) size formats. Each polymer is optimized for specific applications.
• Easy to Use: Pre-formulated and in a single use pouch, which not only saves time but also ensures reliability and consistency
• Include Radio Frequency Identification (RFID) label: Easy to track important information such as Part⁄Lot number, Samples remaining and expiry dates (displayed on software dashboard)
• Robust Formulation: Formulated for sequencing and fragment analysis applications.
• Replenishable: Allow capillaries to be used multiple times.

Reproducible Results
POP™ polymers dynamically coat the capillary wall to control electro-osmotic flow. Their definite quality and uniform consistency eliminate guesswork and help to ensure reproducibility. POP Polymers are specifically formulated to separate DNA fragments of a known size range at a desired resolution and run time.

Many Choices
POP-7™ polymers are very versatile and designed for a wide range of short read to long read sequencing applications as well as fragment analysis. POP-4™ polymers are designed specifically for HID⁄Forensic applications, while POP-6™ polymers are the choice for certain sequencing applications (and fragment analysis).

For partially used pouches that need to be stored, a cap (4412619) that plugs into the pouch fitment opening is recommended.

For Research Use Only. Not for use in diagnostics procedures.

3500xL Genetic Analyzer 24-Capillary Array, 36 cm Applied Biosystems™

The internally uncoated capillaries are supplied in preassembled sets of 24 capillaries per array, with a built-in frame for easy installation.

Applications of the 36 cm capillaries:
HID⁄ Forensic Applications.

For Research Use Only. Not for use in diagnostics procedures.

3130/3100-Avant Genetic Analyzer 4-Capillary Array, 22 cm Applied Biosystems™

This is a 22 cm 4-capillary array (internally uncoated) for the 3130 and 3100 Avant™ Genetic Analyzer. Use for short fragment analysis. Capillary dimensions are 33 cm x 50 µm i.d. Usage per array is 100 runs.

SeqStudio™ Cartridge Applied Biosystems™

The Applied Biosystems SeqStudio Cartridge is an all-in-one and easy-to-use reagent cartridge that includes capillaries, universal polymer, buffer, and pump required to run on the SeqStudio Genetic Analyzer System. The universal polymer allows for flexibility to perform Sanger sequencing and fragment analysis on the same instrument run with the same cartridge. Just load your samples, click in the cartridge, and go.

Key features:
• Minimize hands-on setup time with all-in-one cartridge
• Track consumables usage through radio frequency identification (RFID)
• Extended on-instrument 4-month shelf life for cartridge after opening
• Allows for 125 injections or 500 reactions per cartridge
• Responsible, simple, no-charge recycling program

Results per page
    spinner