Shop All Capillaries & Capillary Arrays

310 Genetic Analyzer Capillary, 47 cm (36 cm wtr - well to read) (Applied Biosystems™)

This is an internally uncoated Capillary for the 310 Genetic Analyzer, 47 cm long. Use for genescan and rapid sequencing applications. 100 runs⁄capillary.

Used With
2.5 µL Glass Syringe, 310 Running Buffer (10X), POP-4® Polymer for the 310 Genetic Analyzer, POP-6™ Polymer for the 310 Genetic Analyzer.

For Research Use Only. Not for use in diagnostics procedures.

310 Genetic Analyzer Capillary, 61 cm (50 cm wtr - well to read) (Applied Biosystems™)

This is an internally uncoated Capillary for the 310 Genetic Analyzer, 61 cm x 50 µm. Use for sequencing applications. 100 runs per capillary.

Used With:
1.0 mL Glass Syringe, 310 Running Buffer, 10X, POP-4® Polymer for the 310 Genetic Analyzer, POP-6™ Polymer for the 310 Genetic Analyzer.

For Research Use Only. Not for use in diagnostics procedures.

SeqStudio™ Cartridge (Applied Biosystems™)

The Applied Biosystems SeqStudio Cartridge is an all-in-one and easy-to-use reagent cartridge that includes capillaries, universal polymer, buffer, and pump required to run on the SeqStudio Genetic Analyzer System. The universal polymer allows for flexibility to perform Sanger sequencing and fragment analysis on the same instrument run with the same cartridge. Just load your samples, click in the cartridge, and go.

Key features:
• Minimize hands-on setup time with all-in-one cartridge
• Track consumables usage through radio frequency identification (RFID)
• Extended on-instrument 4-month shelf life for cartridge after opening
• Allows for 125 injections or 500 reactions per cartridge
• Responsible, simple, no-charge recycling program

3130/3100-Avant Genetic Analyzer 4-Capillary Array, 22 cm (Applied Biosystems™)

This is a 22 cm 4-capillary array (internally uncoated) for the 3130 and 3100 Avant™ Genetic Analyzer. Use for short fragment analysis. Capillary dimensions are 33 cm x 50 µm i.d. Usage per array is 100 runs.

3130xl/3100 Genetic Analyzer 16-Capillary Array, 36 cm (Applied Biosystems™)

This is a 36 cm 16-capillary array (internally uncoated) for the 3130xl and 3100 Genetic Analyzer. Use for fragment analysis and rapid sequencing applications. Capillary dimensions are 47 cm x 50 µm i.d. Usage per array is 100 runs (with use of Applied Biosystems reagents).

3730 DNA Analyzer 48-Capillary Array, 50 cm (Applied Biosystems™)

This is a Capillary Array for the Applied Biosystems® 3730 DNA Analyzers. Each array contains 48 capillaries, 50 cm long. Used for sequencing runs.

Usage per array: 300 runs (with use of Applied Biosystems reagents).

3130xl/3100 Genetic Analyzer 16-Capillary Array, 22 cm (Applied Biosystems™)

This is a 22 cm 16-capillary array (internally uncoated) for the 3130xl and 3100 Genetic Analyzer. Use for short fragment analysis. Capillary dimensions are 33 cm x 50 µm i.d. Usage per array is 100 runs.

3500 Dx Genetic Analyzer 8-Capillary Array, 50 cm (Applied Biosystems™)

These internally uncoated 50 cm capillaries are supplied in preassembled set assemblies of 8 capillaries per array, with a built-in frame for easy installation. A radio-frequency identification (RFID) tag is built into the frame for tracking critical run information, which is then reported on the software dashboard. The arrays can be used for 160 injections in Dx mode.

This product is intended for in-vitro diagnostic use on the Applied Biosystems 3500 Dx Series Genetic Analyzers and is not validated for use with other systems or applications. Refer to the Applied Biosystems 3500 Dx⁄3500xL Dx Genetic Analyzer User Guide for further details.

3130/3100-Avant Genetic Analyzer 4-Capillary Array, 36 cm (Applied Biosystems™)

This is a 36 cm 4-capillary array (internally uncoated) for the 3130 and 3100 Avant™ Genetic Analyzer. Use for sequencing and fragment analysis. Capillary dimensions are 47 cm x 50 µm i.d. Usage per array is 100 runs (with use of Applied Biosystems reagents).

3500xL Dx Genetic Analyzer 24-Capillary Array, 50 cm (Applied Biosystems™)

These internally uncoated 50 cm capillaries are supplied in preassembled sets assemblies of 24 capillaries per array, with a built-in frame for easy installation. Radio frequency identification (RFID) tag is built into the frame for tracking critical run information, which is then reported on the software dashboard. The arrays may be used for 160 injections in Dx mode.

This product is intended for in-vitro diagnostic use on the Applied Biosystems 3500 Dx Series Genetic Analyzers and is not validated for use with other systems or applications. Refer to the Applied Biosystems 3500 Dx⁄3500xL Dx Genetic Analyzer User Guide for further details.

3130xl/3100 Genetic Analyzer 16-Capillary Array, 50cm (Applied Biosystems™)

This is a 50 cm 16-capillary array (internally uncoated) for the 3130xl and 3100 Genetic Analyzer. Use for fragment analysis and sequencing applications. Capillary dimensions are 61 cm x 50 µm i.d. Usage per array is 100 runs (with use of Applied Biosystems reagents).

3730 DNA Analyzer 48-Capillary Array, 36 cm (Applied Biosystems™)

This is a Capillary Array for the Applied Biosystems® 3730 DNA Analyzer. Each array contains 48 capillaries, 36 cm long. Used for both sequencing and fragment analysis runs.

Usage per array: 300 runs (with use of Applied Biosystems reagents).

3130xl/3100 Genetic Analyzer 16-Capillary Array, 80 cm (Applied Biosystems™)

This is an 80 cm 16-capillary array (internally uncoated) for the 3130xl and 3100 Genetic Analyzer. Use for long read sequencing. Capillary dimensions are 91 cm x 50 µm i.d. Usage per array is 100 runs.

3500 Genetic Analyzer 8-Capillary Array, 36 cm (Applied Biosystems™)

The internally uncoated capillaries are supplied in preassembled sets of 8 capillaries per array, with a built-in frame for easy installation.

Applications of the 36 cm capillaries:
HID⁄ Forensic Applications.

For Research Use Only. Not for use in diagnostics procedures.

3500xL Genetic Analyzer 24-Capillary Array, 36 cm (Applied Biosystems™)

The internally uncoated capillaries are supplied in preassembled sets of 24 capillaries per array, with a built-in frame for easy installation.

Applications of the 36 cm capillaries:
HID⁄ Forensic Applications.

For Research Use Only. Not for use in diagnostics procedures.