Shop All IC Columns & Media for Industrial Samples

Dionex™ IonPac™ CS16-4µm and CS16-Fast-4µm IC Columns (Thermo Scientific™)

Analyze disparate concentration ratios of close-eluting cations such as sodium and ammonium with these very high-capacity cation exchange columns.

Dionex™ IonPac™ AS16 IC Columns (Thermo Scientific™)

Measure trace perchlorate and other highly polarizable anions quickly and accurately drinking water, surface water, and ground water matrices.

Dionex™ AminoPac™ PA10 IC Columns (Thermo Scientific™)

For high-resolution separation of free amino acids by the Dionex™ AAA-Direct™ system, choose this pellicular ion-exchange column with no need for derivatization.

Dionex™ IonPac™ AC15 Concentrator Column for IC (Thermo Scientific™)

This anion concentrator column is designed for use with Thermo Scientific™ Dionex™ IonPac™ AS15 Hydroxide-Selective Anion-Exchange Column.

Dionex™ IonPac™ AS12A IC Columns (Thermo Scientific™)

Medium capacity anion-exchange column using a carbonate/bicarbonate eluent for separating inorganic anions and oxyhalides, such as bromate, in environmental waters.

Dionex™ IonPac™ CS3 Analytical & Guard Cation-Exchange Columns (Thermo Scientific™)

Order newer Thermo Scientific™ Dionex™ IonPac™ CS12A column as substitute. This column is available only in limited quantities for customers with established validated methods.

Dionex™ IonPac™ AS18-Fast IC Columns (Thermo Scientific™)

Achieve fast analysis of inorganic anions and low-molecular-weight organic acids in environmental waters in less than 6 min using these high capacity, hydroxide-selective anion-exchange columns.

Dionex™ IonPac™ AS25 Capillary, Analytical & Guard Columns (Thermo Scientific™)

Separate multivalent and polarizable anions including sulfur species in complex matrices in 25 minutes without the use of solvent.

Dionex™ IonPac™ CS19-4µm IC Columns (Thermo Scientific™)

Combine speed with high resolution separations of common inorganic cations, small polar amines and polyvalent amines using this high-capacity cation-exchange column.

Dionex™ IonPac™ AS4A Analytical & Guard Anion-Exchange Columns (Thermo Scientific™)

Order newer Thermo Scientific™ Dionex™ IonPac™ AS22 column as substitute. This column is available only in limited quantities for customers with established validated methods.

Dionex™ IonPac™ AS18-Fast-4µm IC Columns (Thermo Scientific™)

Fast high resolution separations of inorganic anions and low-molecular-weight organic acids in environmental samples in less than 5 minutes using these high capacity, hydroxide-selective anion-exchange columns.

Dionex™ IonPac™ TCC Trace Cation Concentrators (TCC-LP1, TCC-ULP1, TCC-XLP1) (Thermo Scientific™)

Choose from low, ultralow and extremely low pressure formats to concentrate cations for trace-level analysis of high-purity water.

Dionex™ CarboPac™ PA20 IC Columns (Thermo Scientific™)

Quickly and efficiently separate simple sugars without compromising resolution with Thermo Scientific™ Dionex™ CarboPac™ PA20 Columns.

Dionex™ ATC Anion Trap Columns (Thermo Scientific™)

Remove trace anion contaminants from hydroxide or borate eluents with these low-efficiency anion-exchange trap columns.

Dionex™ IonPac™ AS18 IC Columns (Thermo Scientific™)

Analyze inorganic anions and low-molecular-weight organic acids in complex matrices in less than 10 minutes using these 250mm high capacity, hydroxide-selective anion-exchange columns.

Dionex™ IonPac™ Anion Analyte Trap Column (Thermo Scientific™)

The Thermo Scientific™ Dionex IonPac Anion Analyte Trap Column will remove all the analyte anions from a sample in RFIC systems with Eluent Regeneration.

Dionex™ CarboPac™ SA10-4µm IC Columns (Thermo Scientific™)

Analyze six common sugars in food samples in only 10 minutes, or eight common biofuel mono- and disaccharides in less than 8 minutes, using this small-particle anion-exchange column.

Dionex™ IonPac™ AS26 Capillary, Analytical & Guard Columns (Thermo Scientific™)

Separate haloacetic acids and bromate with high sensitivity in drinking water samples with 2D-IC analysis.

Dionex™ IonSwift™ MCC-100 Monolith Cation Concentrator Columns (Thermo Scientific™)

Concentrate cations for general purpose high-purity water analyses and for trace ammonium and amines in high salt matrices by 2D-IC using ultralow pressure concentrator columns.

Dionex™ CarboPac™ PA20-Fast-4µm IC Columns (Thermo Scientific™)

Get shorter run times for simple sugar separations without sacrificing performance by using these shorter columns packed with smaller resin particles.

Dionex™ IonPac™ AS14 IC Columns (Thermo Scientific™)

Medium capacity anion-exchange column for fast isocratic separation of inorganic anions in environmental matrices using a simple carbonate/bicarbonate eluent.

Dionex™ CarboPac™ PA200 IC Columns for Dual EGC Mode

Use these columns for accurate, high-resolution IC separation of complex carbohydrates such as oligosaccharides when operating Dionex HPIC systems in Dual EGC mode.

Dionex™ IonPac™ AS22-Fast-4µm IC Columns (Thermo Scientific™)

Obtain fast, high-resolution separation of common inorganic anions in diverse matrices using this medium capacity anion-exchange column with a carbonate/bicarbonate eluent.

Dionex™ IonPac™ CS15 IC Columns (Thermo Scientific™)

Moderate-capacity cation-exchange column with unique selectivity for the analysis of samples with high ammonium to low ethanolamine ratios.

Dionex™ IonPac™ AS4A-SC IC Columns (Thermo Scientific™)

Low capacity anion-exchange column for fast, isocratic separation of inorganic anions such as nitrate or sulfate using a simple carbonate/bicarbonate eluent.

Dionex™ IonPac™ NS2 5µm Analytical & Guard Columns (Thermo Scientific™)

Order the Thermo Scientific™ Dionex™ IonPac™ NS2 silica-based, high-efficiency, reversed-phase column for separation of charged analytes using mobile phase ion chromatography (MPIC) with suppressed conductivity detection.

Dionex™ IonPac™ AS19-4µm IC Columns (Thermo Scientific™)

Achieve high resolution separations of trace oxyhalides and inorganic anions in drinking water using this 4µm hydroxide-selective anion-exchange column.

Dionex™ IonPac™ AS28-Fast-4µm IC Columns (Thermo Scientific™)

Get fast, high efficiency, high resolution from these 4µm particle columns for trace analysis of common inorganic anions and low molecular weight organic acids.

Dionex™ IonPac™ ICE-Borate IC Columns (Thermo Scientific™)

Monitor trace levels of borate in high-purity water samples using this borate ion-exclusion column.

Dionex™ IonPac™ CS12A IC Columns (Thermo Scientific™)

Separate common cations in diverse matrices in 4 minutes using isocratic acidic eluents with this moderate-capacity, carboxylate-functionalized cation-exchange column.

Dionex™ CTC Cation Trap Columns (Thermo Scientific™)

Remove trace cation contaminants from eluents using these high-capacity, low-efficiency, cation-exchange trap columns.

Dionex™ IonPac™ AS20 IC Columns (Thermo Scientific™)

Simplify trace analysis of perchlorate in drinking water, surface water, and groundwater matrices.

Dionex™ IonPac™ Cation Analyte Trap Column (Thermo Scientific™)

The Thermo Scientific™ Dionex IonPac Cation Analyte Trap Column contains high-capacity, cation-exchange resin in the hydronium form.

Dionex™ IonPac™ ATC-HC and ATC-HC 500 Anion Trap Columns (Thermo Scientific™)

Use this high capacity anion trap column to strip anionic contaminants from deionized water or RFIC-EG eluents to prevent them from reaching the guard or analytical column.

Dionex™ IonPac™ CS19 IC Columns (Thermo Scientific™)

Separate common inorganic cations, small polar amines and polyvalent amines using a high-capacity carboxylate-functionalized cation-exchange column with simple aqueous eluents.

Dionex™ CarboPac™ PA210-Fast-4µm Columns (Thermo Scientific™)

Obtain high efficiency, predictable, high-resolution separation of mono-, di-, tri-, tetra- and pentasaccharides in food samples, without derivatization.

Dionex™ IonPac™ AS11-HC-4µm IC Columns (Thermo Scientific™)

This small-particle column delivers an optimal combination of speed and resolution when separating organic acids and inorganic anions in complex matrices.

Dionex™ CarboPac™ PA10 IC Columns (Thermo Scientific™)

For isocratic separations of mono- and disaccharides in foods, drugs, and plants, Thermo Scientific™ Dionex™ CarboPac™ PA10 Capillary, Analytical & Guard Columns provide superior selectivity.

Dionex™ IonPac™ AS16-4μm Analytical, Capillary, and Guard IC Columns (Thermo Scientific™)

Determine trace levels of perchlorate and other highly polarizable anions in drinking water, surface water, and ground water with these anion exchange columns.

Dionex™ IonPac™ AmG-3µm C18 Analytical and Guard Columns (Thermo Scientific™)

Analyze aminoglycosides with ease, even under harsh conditions, using these specially designed reversed-phase columns.

Dionex™ IonPac™ AS7 IC Columns (Thermo Scientific™)

Separate of a wide variety of polyvalent anions, including hexavalent chromium by U.S. EPA Method 218.6, using this hydrophobic hydroxide-selective anion-exchange column.

Dionex™ IonPac™ AS23-4µm Analytical and Guard Columns (Thermo Scientific™)

Determine trace levels of bromate and other oxyhalides in drinking water, ground water, waste water, and other matrices with these anion exchange columns.

Dionex™ IonPac™ CS5A IC Columns (Thermo Scientific™)

High capacity ion-exchange column for the fast determination of common transition and lanthanide metals simultaneously in diverse matrices.

Dionex™ IonPac™ Low Pressure TAC Trace Anion Concentrator Columns (TAC-LP1, TAC-ULP1) for IC (Thermo Scientific™)

Choose from low and ultralow pressure format for general purpose concentration of anions in high-purity water matrices for trace level analysis.

Dionex™ TMC-1 Trace Metal Concentrator Column (Thermo Scientific™)

Concentrate trace metals for chelation IC using the Thermo Scientific™ Dionex™ TMC-1 Trace Metal Concentrator Column.

Dionex™ IonPac™ AS23 IC Columns (Thermo Scientific™)

High capacity, anion-exchange column that uses an isocratic carbonate/bicarbonate eluent for analysis of trace bromate and other oxyhalides in diverse environmental samples.

Dionex™ IonPac™ AS24A Capillary, Analytical & Guard Columns (Thermo Scientific™)

Separate haloacetic acids and bromate with high sensitivity in drinking water samples with 2D-IC analysis.

Dionex™ CarboPac™ PA100 IC Columns (Thermo Scientific™)

Resolve oligosaccharides released from glycoproteins differing in size, charge, branching, and linkage with Thermo Scientific™ Dionex™ CarboPac™ PA100 Analytical & Guard Columns.

Dionex™ IonPac™ AS11 IC Columns (Thermo Scientific™)

Resolve a large number of inorganic anions and organic acids in approximately 15 minutes.

Dionex™ CarboPac™ SA10 IC Columns (Thermo Scientific™)

Analyze six common sugars in foods or eight common biofuel mono- and disaccharides in only 10 minutes with Thermo Scientific™ Dionex™ CarboPac™ SA10 Analytical & Guard Columns.

Dionex™ CarboPac™ PA1 IC Columns (Thermo Scientific™)

For isocratic determinations of linear polysaccharides and mono- and disaccharides in a variety of matrices, use Thermo Scientific™ Dionex™ CarboPac™ PA1 Analytical & Guard Columns.

Dionex™ IonPac™ AS11-HC IC Columns (Thermo Scientific™)

Resolve a large number of inorganic anions and organic acid anions in complex matrices.

Dionex™ IonPac™ UTAC-1 Series Ultratrace Anion Concentrator Columns, (UTAC-LP1, UTAC-ULP1, UTAC-XLP1) for IC (Thermo Scientific™)

Choose from low, ultralow, and extremely low pressure formats to concentrate anions for trace-level analysis of high-purity water.

Dionex™ IonPac™ CS16 IC Columns (Thermo Scientific™)

Determine disparate concentration ratios of sodium and ammonium in diverse sample matrices using an isocratic eluent with this very high capacity cation exchange column.

Dionex™ IonPac™ AS21 IC Columns (Thermo Scientific™)

For fast analysis of trace perchlorate in drinking water prior to detection with MS/MS.

Dionex™ IonPac™ CP Cation Polisher Columns (CP1 Na+, CP2 H+) (Thermo Scientific™)

Extend analytical column and suppressor life by removing metallic and other cation contaminants using these cation polisher columns for anion analysis.

Dionex™ IonPac™ ICE-AS1 IC Columns (Thermo Scientific™)

For fast analysis of aliphatic organic acids and alcohols in complex- or high-ionic strength samples.

Dionex™ IonPac™ AS24 Analytical & Guard Columns (Thermo Scientific™)

Separate haloacetic acids and bromate in drinking water samples prior to detection with mass spectrometry.

Dionex™ IonPac™ SCS 1 Silica Cation Separator Columns (Thermo Scientific™)

For nonsuppressed conductivity detection or single-column ion chromatography (SCIC), choose this silica cation separatorcolumn.

Dionex™ IonPac™ CS2 Analytical & Guard Cation-Exchange Columns (Thermo Scientific™)

Order newer Thermo Scientific™ Dionex™ IonPac™ CS12A column as substitute. This column is available only in limited quantities for customers with established validated methods.