Shop All Chromatography Instruments & Equipment

Dionex™ OnGuard™ II RP Cartridges, 1mL Thermo Scientific™

Remove hydrophobic substances such as aromatic dyes, some aromatic carboxylic acids, hydrocarbons, and surfactants from sample matrices to improve IC performance and facilitate low-level ion analysis. Thermo Scientific™ Dionex™ OnGuard™ II RP Cartridges are an off-line sample preparation technique that uses a macroporous divinylbenzene resin with very high selectivity for hydrophobic substances to eliminate these matrix interferences. Use these cartridges singly or in series, or pretreat up to 12 samples in parallel using the optional Thermo Scientific™ Dionex™ OnGuard™ Sample Prep Station.

Dionex™ OnGuard™ II RP Cartridges, 2.5mL Thermo Scientific™

Remove hydrophobic substances such as aromatic dyes, some aromatic carboxylic acids, hydrocarbons, and surfactants from sample matrices to improve IC performance and facilitate low-level ion analysis. Thermo Scientific™ Dionex™ OnGuard™ II RP Cartridges are an off-line sample preparation technique that uses a macroporous divinylbenzene resin with very high selectivity for hydrophobic substances to eliminate these matrix interferences. Use these cartridges singly or in series, or pretreat up to 12 samples in parallel using the optional Thermo Scientific™ Dionex™ OnGuard™ Sample Prep Station.

TurboFlow™ Columns for Automated Online LC-MS Sample Cleanup Thermo Scientific™

Use Thermo Scientific™ TurboFlow™ Columns for automated online matrix cleanup of complex matrices analyzed on the Thermo Scientific™ Aria™, Transcend™ TLX, and Prelude™ LC-MS systems. Placed before the analytical column, TurboFlow sample cleanup columns enable direct injection of complex matrices such as food, plasma, urine, and other biological matrices into the mass spectrometry (MS) system without prior sample pretreatment. The patented TurboFlow column design retains compounds of interest for subsequent analysis, while complex matrices quickly and completely elute to waste.

Dionex™ OnGuard™ II H Cartridges, 1mL Thermo Scientific™

Remove high levels of alkaline earth and transition metals from sample matrices and neutralize highly alkaline samples such as sodium hydroxide or sodium carbonate. Carbonate can then be removed by sparging the sample. The Thermo Scientific™ Dionex™ OnGuard™ II H Cartridge is an off-line sample preparation technique that eliminates these matrix interferences to improve ion chromatography (IC) performance and facilitate low-level ion analysis. Use them singly or in series, or pretreat up to 12 samples in parallel using the optional Thermo Scientific Dionex OnGuard Sample Prep Station.

TRACE™ 1310 GC Analyzers for Permanent Gases & Trace Impurities Thermo Scientific™

Refuse to compromise by choosing from our variety of Thermo Scientific™ TRACE™ 1310 gas chromatography systems for the analysis of industrial gas streams. These systems can be used in laboratories and in pilot/scale-up to at-line environments. Whether you need to analyze permanent gases, hydrogen, low levels of CO/CO2, impurities in chlorine, trace-level impurities in pure gases or a combination of those analyses, there is a system to meet your requirements. TRACE 1310 analyzers for industrial gas streams come pre-configured, factory tested and ready to connect to your lab services.

Dionex™ OnGuard™ II H Cartridges, 2.5mL Thermo Scientific™

Remove high levels of alkaline earth and transition metals from sample matrices and neutralize highly alkaline samples such as sodium hydroxide or sodium carbonate. Carbonate can then be removed by sparging the sample. The Thermo Scientific™ Dionex™ OnGuard™ II H Cartridge is an off-line sample preparation technique that eliminates these matrix interferences to improve ion chromatography (IC) performance and facilitate low-level ion analysis. Use them singly or in series, or pretreat up to 12 samples in parallel using the optional Thermo Scientific Dionex OnGuard Sample Prep Station.

Dionex™ AS-DV Autosampler PolyVials and Caps Thermo Scientific™

Available in 0.5mL and 5.0mL sizes, Thermo Scientific™ Dionex™ AS-DV Autosampler PolyVials are supplied in packs of 250, with and without plain or filter caps. Choose from compatible vial holders, adapters and a vial cap removal tool to complete your setup for the AS-DV Autosampler.

Dionex™ OnGuard™ II P Cartridges, 1mL Thermo Scientific™

Remove the phenolic fraction of humic acids, tannic acids, lignins, anthocyanins, and azodyes from sample matrices. Thermo Scientific™ Dionex™ OnGuard™ II P Cartridges are an off-line sample preparation technique that uses polyvinylpyrrolidone (PVP) polymer with very high selectivity to eliminate these matrix interferences to improve IC performance and facilitate low-level ion analysis. Use Dionex OnGuard II P Cartridges singly or in series, or pretreat up to 12 samples in parallel using the optional Thermo Scientific Dionex OnGuard Sample Prep Station.

Rocket™ Evaporator Chiller Connection Kit Thermo Scientific™

Order this Thermo Scientific™ Rocket™ Evaporator Chiller Connection Kit for all the tubing, connections, and the RS232 cable needed to connect the chiller to your Rocket Evaporator. The chiller is the cooling system that traps solvent evaporated from the sample in the Rocket Evaporator. Refer to the Rocket Evaporator Chiller if you need to replace the recirculating solvent chiller system.

Dionex™ OnGuard™ II Ag Cartridges, 1mL Thermo Scientific™

Remove chloride, bromide, and iodide from sample matrices to improve performance of ion chromatography (IC) and facilitate trace analyses. Performed prior to IC analysis, the Thermo Scientific™ Dionex™ OnGuard™ II Ag Cartridge is an off-line sample preparation technique that eliminates these matrix interferences using a silver-form, high-capacity, suffocated, cation-exchange resin. Pretreat a single sample or many samples in series. Use them singly or in series, or pretreat up to 12 samples in parallel using the optional Thermo Scientific™ Dionex™ OnGuard™ Sample Prep Station.

Rocket™ Evaporator Flasks Thermo Scientific™

Dry or concentrate large-volume sample extracts in automated systems with Thermo Scientific™ Rocket™ Evaporator Flasks. Use up to six 450mL borosilicate flasks in parallel. These flasks are useful when dried samples need to be removed by pipette for subsequent analysis.

Fraction Collector FT/F

Achieve compatibility while maintaining versatility: the Thermo Scientific™ Fraction Collector FT/F platform performs UHPLC and HPLC purification on a wide range of sample types, including proteins and active pharmaceutical compounds, and is fully compatible with Thermo Scientific™ Vanquish™ UHPLC systems and the Thermo Scientific™ UltiMate™ 3000 HPLC and UHPLC systems.

UltiMate™ 3000 Amperometric Electrochemical Cell Electrodes Thermo Scientific™

Find the right Thermo Scientific™ Dionex™ UltiMate™ 3000 Amperometric Electrochemical Cell Electrodes for your amperometric electrochemical analyses utilizing 5040/5041/5041A cells. They are available as target, reference or working electrodes for a variety of electrochemical analyses.

Dionex™ ASE™ 150/350 Stainless Steel Extraction Cells Thermo Scientific™

These convenient Thermo Scientific™ Dionex™ ASE™ 150 and 350 Stainless Steel Extraction Cell Kits include 1mL to 100mL extraction cells. Complete with end caps, seals, and O-rings, you can order them as individual cells or in packs of six.

Dionex ASE Accelerated Solvent Extractors reduce sample preparation from hours to minutes by performing automated solvent extraction on solid and semisolid sample matrices. Extraction cells feature finger-tight cell caps with compression seal for high-pressure closure and maximum ease of use.

Dionex™ OnGuard™ II Ag Cartridges, 2.5mL Thermo Scientific™

Remove chloride, bromide, and iodide from sample matrices to improve performance of ion chromatography (IC) and facilitate trace analyses. Performed prior to IC analysis, the Thermo Scientific™ Dionex™ OnGuard™ II Ag Cartridge is an off-line sample preparation technique that eliminates these matrix interferences using a silver-form, high-capacity, suffocated, cation-exchange resin. Pretreat a single sample or many samples in series. Use them singly or in series, or pretreat up to 12 samples in parallel using the optional Thermo Scientific™ Dionex™ OnGuard™ Sample Prep Station.
Results per page
    spinner