Shop All Chromatography Instruments & Equipment

Dionex™ ASE™ 150 Accelerated Solvent Extractor Thermo Scientific™

Extract analytes from solid and semisolid samples in minutes using the Thermo Scientific™ Dionex™ ASE™ 150 Accelerated Solvent Extractor. This system automates extraction, filtration and cleanup of a single sample, accommodates sample sizes of 1 to 100g and uses 50 to 90% less solvent than other extraction methods. The chemically inert pathway supports acid and alkaline sample matrices and solvents. Flexible, easy-to-operate and cost-effective, the ASE 150 is designed for use in lower-throughput laboratories for a wide range of applications.

Dionex™ ASE™ 350 Accelerated Solvent Extractor Thermo Scientific™

Automate extraction, filtration and clean up of compounds from solid and semisolid samples in minutes using the automated Thermo Scientific™ Dionex™ ASE™ 350 Accelerated Solvent Extractor. This system accommodates sample sizes of 1-100g, allows unattended extraction of up to 24 samples and uses 50 to 90% less solvent compared to other methods. The chemically inert pathway supports acid and alkaline sample matrices and solvents. Flexible, easy-to-operate and cost-effective, the Dionex ASE 350 is ideally suited for high-throughput laboratories and for a wide variety of applications.

Buffer Tubing for UltiMate™ 3000 Autosamplers, Biocompatible Thermo Scientific™

Choose Thermo Scientific™ Dionex™ Biocompatible Buffer Tubing for Thermo Scientific™ UltiMate™ 3000 Autosamplers, available in volumes from 50 to 2000µL. Select the biocompatible buffer tubing volume of choice your biocompatible LC system.

Dionex™ AutoTrace™ 280 Solid-Phase Extraction Instrument Thermo Scientific™

Extract analytes of interest from large volume aqueous samples easily and efficiently with the Thermo Scientific™ Dionex™ AutoTrace™ 280 Solid-Phase Extraction (SPE) Instrument. The AutoTrace 280 automates all four steps of SPE (conditioning, loading, rinsing, and eluting), reducing solvent consumption and improving recovery and reproducibility. Boost productivity and reduce cost of analysis by simultaneously processing up to six samples in 2-3 hours with only 15 minutes of operator involvement. The AutoTrace 280 meets requirements in US EPA methods including the 500 and 600 series.

pH Gradient Buffers Thermo Scientific™

Obtain fast and highly robust, reproducible HPLC gradients using Thermo Scientific™ CX-1 pH Gradient Buffers. Simple to optimize and easily automated, these buffers are applicable for HPLC separation of the majority of monoclonal antibody (mAb) biotherapeutics drugs. CX-1 pH Gradient Buffers are ready to use with existing HPLC columns without the need to formulate mobile phases. The CX-1 buffers save time in method development, facilitate method transfer to QA/QC for a wide range of mAb charge variants through a generic HPLC-based approach to mAb characterization, and do not require time-consuming mobile phase adjustments.

250µL Syringe Upgrade Kits Thermo Scientific™

Choose Thermo Scientific™ Dionex™ Syringe Upgrade Kit for 250µL syringe includes syringe, needle, buffer tubing, and sample loop (125µL) for the WPS-3000TBPL Nano/Cap autosampler.

Rheodyne™ Ports for Injector Models 7010 and 9010 Thermo Scientific™

Use Thermo Scientific™ Rheodyne Ports for Models 7010 and 9010 Injectors for high-performance liquid chromatography (HPLC).

UltiMate™ 3000 Pump Pistons Thermo Scientific™

Order these replacement Thermo Scientific™ Dionex™ UltiMate™ 3000 Pump Pistons when needed. Pistons are available in ceramic and sapphire to meet the needs of your specific pump.

Injection Port Liners for Agilent GC Instruments Thermo Scientific™

Optimize the performance of Agilent™ GC systems with our specifically designed Thermo Scientific™ Injection Port Liners for Agilent instruments. Highly deactivated and produced to exacting tolerances, these injection liners ensure exceptional reproducibility.

HyperSep™ C18 Plates Thermo Scientific™

The use of SPE sample preparation can significantly enhance the robustness and reliability of many biological, pharmaceutical, forensic and environmental applications. Thermo Scientific™ HyperSep™ C18 Plates feature a highly retentive alkyl-bonded phase for nonpolar to moderately polar compounds. The hydrophobic reversed phase material is retentive for most nonpolar compounds, and retains most organic analytes from aqueous matrices.

PEEK Biocompatible Sample Loops for Pulled Loop Autosamplers Thermo Scientific™

Order the Thermo Scientific™ Biocompatible Sample Loops (5-250µL) you need for Thermo Scientific™ Dionex™ UltiMate™ WPS-3000TBPL pulled loop autosamplers.

SLIPFREE™ HPLC Column Single Connectors Thermo Scientific™

Ensure excellent column connections and optimal HPLC performance with Thermo Scientific™ SLIPFREE™ HPLC Column Single Connectors. Compatible with all column end-fittings, these universal, self-adjusting connectors provide leak- and void-free column connections. Fingertight connections up to 10000psi ensure ease of use. They are ideal for supercritical fluid columns (SFC). SLIPFREE connectors are available in a variety of configurations and designs for a broad range of applications.

Dionex™ Viper™ Extension Kit for UltiMate™ 3000 Quaternary SD/RS AMS Setup Thermo Scientific™

Thermo Scientific™ Dionex Viper Capillary Kits for Analytical System Variants feature built-in zero dead volume by sealing at the tip of the tubing.

nanoViper™ Fingertight Fittings, 100µm Thermo Scientific™

Maximize nano liquid chromatography (LC) performance and convenience with Thermo Scientific™ nanoViper™ Fingertight Fittings. Virtually zero-dead-volume connections ensure optimal separation efficiencies. Preassembled and finger-tightened, nanoViper fingertight fittings enable easy, tool-free instrument setup and configuration, and prevent overtightening. High pressure tested, these fittings provide UHPLC compatibility up to 1200 bar (17,400 psi).

Dionex™ ICS-6000 Standard Bore and Microbore HPIC™ Systems Thermo Scientific™

Get significant increases in resolution and throughput using the world's first modular ion chromatography (IC) system capable of operation up to 5000 psi. The Thermo Scientific™ Dionex™ ICS-6000 Standard Bore and Microbore System can operate continuously at up to 5000 psi when configured as a Reagent-Free™ IC (RFIC™) system. Get higher resolution using smaller particle size (4µm) columns, faster run times without sacrificing needed resolution using higher flow rates and 150mm columns, or higher resolution with standard flow rates and 250mm columns. The ability to configure this flexible, modular system for an unmatched variety of applications.

Results per page
    spinner