SPE Systems

SPE Systems

Instruments, adapters, replacement parts, and other accessories designed for sample preparation applications using solid-phase extraction. Products are compatible with a variety of columns, cartridges, tubes, etc., and include vacuum and pressure manifolds.
Products (41)
Learn More (121)

Documents & Support

(41)
41 Products
Filter
  • Show all
  • Show all
  • Show all
  • Show all
  • Show all
  • Show all
Product
Voltage
Type
Dimensions (D x W x H)
Size
Price
 
Pre-Drilled Waste ContainerEach
Column AdaptorsPack of 15
Teflon TipsPack of 12
Gauge and Waste BaseEach
Universal Vacuum ManifoldEach
Vacuum ManifoldEach
100/240 V ±10% AutoTrace 280 PFAS SystemInstrument: 57 x 63.5 x 69 cmEach
μSPE KitEach
Autosampler accessoryEach
24 Position Extraction Plate PlugsEach
48 Position Extraction Plate PlugsEach
Collection RackEach
Collection RackEach
Glass BlockEach
Vacuum Gauge and Valve AssemblyEach
Vacuum GaugeEach
StopcocksPack of 24
StopcocksPack of 16
Vacuum PumpEach 1
Vacuum PumpEach
Luer Lock PlugsEach
Bulkhead Luer FittingsEach
Manifold Lid LegsEach
Vacuum Manifold LidEach
GasketEach
GasketEach
Retaining ClipsEach
Collection RackEach
Collection RackEach
Positive Pressure Manifold with Collection RackEach
Use the Thermo Scientific™ HyperSep™ Positive Pressure Manifold Waste Container to collect waste from the manifold. The HyperSep Positive Pressure Manifold holds up to 48 SPE cartridges. Samples and solvent, added to the SPE cartridge, are extracted under positive pressure for an even flow at each...
Use the Thermo Scientific™ HyperSep™ Glass Block Vacuum Manifold Cartridge Adaptors for using various sized solid phase extraction (SPE) cartridges on the glass block vacuum manifold for sample preparation.
Use the Thermo Scientific™ HyperSep™ Glass Block Vacuum Manifold Tips to direct the flow of extract from the HyperSep solid phase extraction SPE cartridges to the collection tubes. They are available in packs of 12.
Order the Thermo Scientific™ HyperSep™ Universal Vacuum Manifold, Gauge and Waste Base as a replacement spare part for your HyperSep Universal Vacuum Manifold. This manifold processes samples in solid phase extraction SPE cartridges or 96 well plate.
Process your samples in solid phase extraction SPE cartridges or 96 well plates by using the flexible Thermo Scientific™ HyperSep™ Universal Vacuum Manifold. The manifold is supplied with a base and vacuum gauge, flask and stopper tubing and spigots.
Thermo Scientific™ HyperSep™ Vacuum Manifolds are designed for use with HyperSep SPE columns and HyperSep-96™ well plates.
Get automated solid phase extraction (SPE) for PFAS sample preparation with Thermo Scientific™ Dionex™ AutoTrace™ 280 PFAS and reduce your risk of background contamination using an instrument with non-fluoropolymer-based tubing, valves, and filters.
Helping laboratories achieve reliable and high-throughput GC-MS analysis of pesticides, the automated cartridge-based micro Solid Phase Extraction (μSPE) Clean-up Tool for QuEChERS extracts is available for the TriPlus™ RSH and TriPlus RSH SMART Autosamplers.
Achieve ppt-level sensitivity for volatile organic compounds (VOCs) by integrating dynamic headspace enrichment into your automated sampling workflow for gas chromatography (GC). The ITEX-DHS tool enables a robust, easy-to-use, syringe-based headspace enrichment technique that offers high sorbent...
Use these 24 or 48 well extraction plates and plugs with Thermo Scientific™ HyperSep™ Universal Vacuum Manifold. This manifold process your samples in solid phase extraction SPE cartridges or 96 well plates.
Use these 24 or 48 well extraction plates and plugs with Thermo Scientific™ HyperSep™ Universal Vacuum Manifold. This manifold process your samples in solid phase extraction SPE cartridges or 96 well plates.
Use the Thermo Scientific™ HyperSep™ Positive Pressure Manifold Collection Rack that matches the collection tube size being used. The HyperSep Positive Pressure Manifold prepares up to 48 samples by solid phase extraction (SPE) simultaneously. Extracts are collected into 13 or 16mm tubes.
Use the Thermo Scientific™ HyperSep™ Positive Pressure Manifold Collection Rack that matches the collection tube size being used. The HyperSep Positive Pressure Manifold prepares up to 48 samples by solid phase extraction (SPE) simultaneously. Extracts are collected into 13 or 16mm tubes.
Order the Thermo Scientific™ HyperSep™ Vacuum Manifold Glass Block if you need a replacement. The vacuum chamber for this manifold is a glass block that allows you to see the extraction process and provides easy cleaning.
Order the Thermo Scientific™ HyperSep™ Glass Block Vacuum Manifold Vacuum Gauge if you need a replacement. The manifold enables processing of 16 or 24 samples through HyperSep SPE solid phase extraction cartridges under vacuum. The gauge is available separately or with the valve assembly.
Order the Thermo Scientific™ HyperSep™ Glass Block Vacuum Manifold Vacuum Gauge if you need a replacement. The manifold enables processing of 16 or 24 samples through HyperSep SPE solid phase extraction cartridges under vacuum. The gauge is available separately or with the valve assembly.
Control the flow of extract exiting your SPE cartridge using Thermo Scientific™ HyperSep™ Glass Block Vacuum Manifold Stopcocks. The manifold enables you to process 16 or 24 samples through HyperSep SPE solid phase extraction cartridges under vacuum.
Control the flow of extract exiting your SPE cartridge using Thermo Scientific™ HyperSep™ Glass Block Vacuum Manifold Stopcocks. The manifold enables you to process 16 or 24 samples through HyperSep SPE solid phase extraction cartridges under vacuum.
The use of SPE sample preparation can significantly enhance the robustness and reliability of many biological, pharmaceutical, forensic and environmental applications. We offer a full range of extraction accessories to complement both traditional cartridges and 96-well plate formats.
The use of SPE sample preparation can significantly enhance the robustness and reliability of many biological, pharmaceutical, forensic and environmental applications. We offer a full range of extraction accessories to complement both traditional cartridges and 96-well plate formats.
Order these Thermo Scientific™ HyperSep™ Vacuum Manifold Luer fittings and plugs when you need a replacement. The HyperSep Glass Block Vacuum Manifold enables sample preparation by solid phase extraction using 16 or 24 SPE cartridges.
Order these Thermo Scientific™ HyperSep™ Vacuum Manifold Luer fittings and plugs when you need a replacement. The HyperSep Glass Block Vacuum Manifold enables sample preparation by solid phase extraction using 16 or 24 SPE cartridges.
The use of SPE sample preparation can significantly enhance the robustness and reliability of many biological, pharmaceutical, forensic and environmental applications. We offer a full range of extraction accessories to complement both traditional cartridges and 96-well plate formats.
The use of SPE sample preparation can significantly enhance the robustness and reliability of many biological, pharmaceutical, forensic and environmental applications. We offer a full range of extraction accessories to complement both traditional cartridges and 96-well plate formats.
Replace the gasket in the Thermo Scientific™ HyperSep™ Glass Block Vacuum Manifold as needed to maintain a vacuum and prevent leaking. The HyperSep Glass Block Vacuum Manifold enables solid phase extraction sample preparation using 16 or 24 SPE cartridges.
Replace the gasket in the Thermo Scientific™ HyperSep™ Glass Block Vacuum Manifold as needed to maintain a vacuum and prevent leaking. The HyperSep Glass Block Vacuum Manifold enables solid phase extraction sample preparation using 16 or 24 SPE cartridges.
Select a 16- or 24-position collection rack for use with the Thermo Scientific™ HyperSep™ Glass Block Vacuum Manifold. The manifold enables solid phase extraction sample preparation using SPE cartridges. Extracts are collected into tubes in the collection rack.
Select a 16- or 24-position collection rack for use with the Thermo Scientific™ HyperSep™ Glass Block Vacuum Manifold. The manifold enables solid phase extraction sample preparation using SPE cartridges. Extracts are collected into tubes in the collection rack.
Select a 16- or 24-position collection rack for use with the Thermo Scientific™ HyperSep™ Glass Block Vacuum Manifold. The manifold enables solid phase extraction sample preparation using SPE cartridges. Extracts are collected into tubes in the collection rack.
Improve productivity of solid phase extraction (SPE) sample preparation by simultaneously processing up to 48 samples. The Thermo Scientific™ HyperSep™ Positive Pressure Manifold can hold 48 SPE cartridges of various sizes: 1, 3, 6, and 10/15mL.
Results per page15 30 60