Dionex™ IonPac™ AS11 IC Columns Thermo Scientific™

Resolve a large number of inorganic anions and organic acids in approximately 15 minutes with the Thermo Scientific™ Dionex™ IonPac™ AS11 Analytical & Guard Column. The Dionex IonPac AS11 is a relatively low-capacity column designed for fast gradient screening of inorganic anions and organic acid...

Dionex™ IonPac™ AS14 IC Columns Thermo Scientific™

Deliver excellent results for fast isocratic separations of inorganic anions in diverse matrices with the Thermo Scientific™ Dionex™ IonPac™ AS14 Carbon Eluent Anion-Exchange Column. This universal column for the separation of inorganic anions delivers improved peak resolution and retention of...

Dionex™ IonPac™ AS11-HC IC Columns Thermo Scientific™

Resolve a large number of inorganic anions and organic acid anions in complex matrices with the Thermo Scientific™ Dionex™ IonPac™ AS11-HC Capillary, Analytical & Guard Column. Complex sample matrices such as chemical wastewater effluents and fermentation broth solutions contain a variety of...

Dionex™ IonPac™ AS23 IC Columns Thermo Scientific™

Measure trace bromate and other oxyhalides in drinking water, ground water, wastewater, and other diverse sample matrices with the Thermo Scientific™ Dionex™ IonPac™ AS23 carbonate eluent anion-exchange column.

Dionex™ IonPac™ AS7 IC Columns Thermo Scientific™

For separation of a wide variety of polyvalent anions, including polyphosphates, polyphosphonates, and other polyvalent complexing agents, the Thermo Scientific™ Dionex™ IonPac™ AS7 anion-exchange column delivers excellent results.

Dionex™ IonPac™ AS22 IC Columns Thermo Scientific™

Designed specifically for compliance monitoring of inorganic anions in accordance with U.S. EPA Methods 300.0 (A), the Thermo Scientific™ Dionex™ IonPac™ AS22 Analytical, Capillary & Guard Columns provide fast analysis of drinking water, ground water and wastewater.

Dionex™ CarboPac™ PA20 IC Columns Thermo Scientific™

Quickly and efficiently separate simple sugars without compromising resolution with Thermo Scientific™ Dionex™ CarboPac™ PA20 Columns. Combined with pulsed amperometric detection (PAD), these strong anion-exchange columns provide high-resolution separations at high pH with no need for...

Dionex™ IonPac™ CS12 IC Columns Thermo Scientific™

Obtain robust, reliable results and fast isocratic separation of common inorganic cations and alkanolamines using the Thermo Scientific™ Dionex™ IonPac™ CS12 Cation-Exchange Column. This is a high-capacity, cation-exchange column designed for the fast, isocratic separation of lithium, sodium,...

Dionex™ IonPac™ CS19-4µm IC Columns Thermo Scientific™

Attain the optimal combination of chromatographic speed and high resolution using the new Thermo Scientific™ Dionex™ IonPac™ CS19-4µm Capillary, Analytical, & Guard Column. This high-capacity, high-resolution carboxylate-functionalized column provides excellent resolution of common cations, small...

Dionex™ IonPac™ AS3 Analytical & Guard Anion-Exchange Columns Thermo Scientific™

Use newer Thermo Scientific™ Dionex™ IonPac™ AS22 columns as substitutes for Dionex IonPac AS3 Analytical & Guard Anion-Exchange Columns. The Dionex IonPac AS3 is available in limited quantities while supplies last for customers who have established validated methods using this column.

Dionex™ IonPac™ AS20 IC Columns Thermo Scientific™

Simplify trace analysis of perchlorate in drinking water, surface water, and groundwater matrices using the Thermo Scientific™ Dionex™ IonPac™ AS20 Capillary, Analytical & Guard Columns. The capacity and selectivity of this column ensures that perchlorate can be quantified at low µg/L concentrations...

Dionex™ IonPac™ AS29-Fast-4µm Analytical and Guard IC Columns Thermo Scientific™

Analyze inorganic anions in high ionic strength matrices using Thermo Scientific™ Dionex™ AS29-Fast-4µm ion chromatography (IC) columns. Specifically designed to handle high ionic strength samples, Dionex IonPac AS29-Fast-4µm columns can easily separate the common inorganic anions in less than 10...

Dionex™ IonPac™ AS22-Fast-4µm IC Columns Thermo Scientific™

Attain the optimal combination of chromatographic speed and resolution using the Thermo Scientific™ Dionex™ IonPac™ AS22-Fast-4µm column. Designed specifically for compliance monitoring of inorganic anions in accordance with U.S. EPA Method 300.

Dionex™ IonSwift™ MAC Monolith Anion Concentrator Columns (MAC-100, MAC-200) for IC Thermo Scientific™

Use these ultraclean (low sulfate), ultralow-backpressure, low-void volume monolithic anion-exchange columns to concentrate anions for water sample analyses. Choose the Thermo Scientific™ Dionex™ IonSwift™ MAC-100 Monolith Anion Concentrator for general purpose, high purity water analysis.

POROS™ GoPure™ XQ Pre-packed Column, 0.8 x 10 cm, 5 mL Thermo Scientific™

POROS GoPure 0.5 cm diameter x 5 cm long prepacked columns are intended for screening of POROS affinity, ion exchange, and hydrophobic interaction chromatography (HIC) resins or for small scale purification.

Dionex™ IonPac™ CS2 Analytical & Guard Cation-Exchange Columns Thermo Scientific™

Use newer Thermo Scientific™ Dionex™ IonPac™ CS12A columns as substitutes for Dionex IonPac CS2 Analytical & Guard Cation-Exchange Columns. Dionex IonPac CS2 columns are only available in limited quantities for customers who have established validated methods using this column.

Dionex™ IonPac™ AS4A Analytical & Guard Anion-Exchange Columns Thermo Scientific™

Use the newer Thermo Scientific™ Dionex™ IonPac™ AS22 columns as substitutes for Dionex IonPac AS4A Analytical & Guard Cation-Exchange Columns. Dionex IonPac AS4A columns are now only available in limited quantities for customers who have established validated methods using this column.

Dionex™ MetPac™ CC-1 Cation Concentrator Thermo Scientific™

Use the Thermo Scientific™ Dionex™ MetPac™ CC-1 Cation Concentrator in chelation IC and IC-ICP to concentrate cationic transition metals from high-ionic-strength matrices. This concentrator has high selectivity for transition and lanthanide elements relative to the alkali and alkaline-earth metals,...

Dionex™ IonPac™ AS11-HC-4µm IC Columns Thermo Scientific™

Achieve the optimal combination of chromatographic speed and resolution in separating organic acids and inorganic anions in complex matrices using the new Thermo Scientific™ Dionex™ IonPac™ AS11-HC-4µm Capillary, Analytical & Guard Column.

Dionex™ IonPac™ CS16-4µm and CS16-Fast-4µm IC Columns Thermo Scientific™

Analyze disparate concentration ratios up to 10,000:1 of close-eluting cations such as ammonium and sodium using Thermo Scientific™ Dionex™ IonPac™ CS16-4µm and CS16-Fast-4µm columns. Designed specifically for the analysis of cations at diverse concentration ratios, this high-capacity column...

Dionex™ CarboPac™ PA210-Fast-4µm Columns Thermo Scientific™

Obtain predictable, high-resolution, high efficiency separations of food sugars, namely mono-, di-, tri-, tetra- and pentasaccharides in various types of food samples. Thermo Scientific™ Dionex™ CarboPac™ PA210-Fast-4µm IC columns resolve and quantify glucose, galactose, fructose, sucrose, rhamnose,...

Dionex™ IonPac™ AC10 Concentrator Column for IC Thermo Scientific™

When using the Thermo Scientific™ Dionex™ IonPac™ AS10 Anion Concentrator Column, the Dionex IonPac AC10 Concentrator Column is the anion concentrator of choice. The Dionex IonPac AC10 concentrator is offered in two formats, 4 x 50mm and 2 x 50mm.

Dionex™ IonPac™ AS9-SC IC Columns Thermo Scientific™

Separate inorganic anions and oxyhalides in simple matrices using an isocratic carbonate/bicarbonate eluent with the Thermo Scientific™ Dionex™ IonPac™ AS9-SC Carbonate Eluent Anion-Exchange Column. The Dionex IonPac AS9-SC column is specified in US EPA Method 300.

Dionex™ ED Electrochemical Detector AAA Direct Installation Kit Thermo Scientific™

Use the Thermo Scientific™ Dionex™ ED Electrochemical Detector AAA-Direct Installation Kit with the PA10 Analytical column and IC Electrochemical detection.

Dionex™ IonPac™ CS12A IC Columns Thermo Scientific™

Separate common cations in as little as four minutes using methanesulfonic acid (MSA) or sulfuric acid eluents with Thermo Scientific™ Dionex™ IonPac™ CS12A Cation-Exchange Columns. These medium-capacity, carboxylate-functionalized cation-exchange columns are recommended for fast, isocratic...

Dionex™ IonPac™ CS16 IC Columns Thermo Scientific™

Determine disparate concentration ratios of adjacent eluting cations such as sodium and ammonium in diverse sample matrices using the Thermo Scientific™ Dionex™ IonPac™ CS16 Capillary, Analytical & Guard Column.

DNASwift™ SAX-1S Oligonucleotide Columns Thermo Scientific™

Use a strong anion-exchange column with the Thermo Scientific™ DNASwift™ SAX-1S Oligonucleotide Column that provides exceptionally high resolution for the purification of oligonucleotides.

Dionex™ IonPac™ ICE-AS1 IC Columns Thermo Scientific™

For fast analysis of aliphatic organic acids and alcohols in complex or high-ionic strength samples, the Thermo Scientific™ Dionex™ IonPac™ ICE-AS1 Analytical & Guard Columns delivers consistent reliable results.

Dionex™ IonSwift™ MAX-100 Analytical & Guard Columns Thermo Scientific™

Separate organic acids and inorganic anions in complex matrices in approximately 25 minutes using the Thermo Scientific™ Dionex™ IonSwift™ MAX-100 Anion-Exchange column. Dionex IonSwift columns use monolith media, which is uniquely designed and engineered for fast separation of small molecules,...

Dionex™ IonPac™ ATC-HC and ATC-HC 500 Anion Trap Columns Thermo Scientific™

Use Thermo Scientific™ Dionex™ IonPac™ ATC-HC and ATC-HC 500 Anion Trap Columns to strip anionic contaminants from deionized water or RFIC-EG eluents to prevent them from reaching the guard or analytical column. These high-capacity trap columns are designed specifically for use with RFIC-EG systems.