Ion Chromatography Columns

Ion Chromatography Columns

Columns, cartridges, and guard columns for separating samples based on their interactions with a resin stationary phase and an eluent mobile phase. Products employ various separation modes and are available in formats including standard bore, microbore, and capillary.
Read more Read less
76-90 of 119 Products

Dionex™ CTC Cation Trap Columns Thermo Scientific™

Remove trace cation contaminants from eluents using the Thermo Scientific™ Dionex™ IonPac™ CTC-1 and Dionex IonPac CTC 500 Cation Trap Columns. These high-capacity, low-efficiency, cation-exchange trap columns are installed in the eluent line after the pump prior to the injection valve to prevent...

Dionex™ MFC-1 Metal-Free Trap Columns Thermo Scientific™

Packed with a special chelating resin, the Thermo Scientific™ Dionex™ MFC-1 and MFC 500 Metal-Free Trap Columns are used in the eluent line prior to the injection valve to remove transition metals from high-pH eluents.

Dionex™ ATC Anion Trap Columns Thermo Scientific™

Remove trace anion contaminants from hydroxide or borate eluents with the Thermo Scientific™ Dionex™ IonPac™ ATC-3 and Dionex IonPac ATC 500 Anion Trap Columns. These trap columns are installed in the eluent line after the pump prior to the injection valve to prevent spurious peaks and to minimize...

Dionex™ IonPac™ AS19-4µm IC Columns Thermo Scientific™

Achieve high resolution separations of trace oxyhalides and inorganic anions in drinking water using the Thermo Scientific™ Dionex™ IonPac™ AS19-4µm hydroxide-selective anion-exchange column. Its high resolution, high capacity and selectivity allow the determination of bromate in drinking water at...

Dionex™ CarboPac™ SA10-Fast-4µm IC Columns Thermo Scientific™

Use the shorter 150mm Thermo Scientifc™ Dionex™ CarboPac™ SA10-Fast-4µm columns for fast separation of simple sugars in biofuels and food samples with better resolution and easier peak identification and integration.

Dionex™ IonPac™ CS19-4µm IC Columns Thermo Scientific™

Attain the optimal combination of chromatographic speed and high resolution using the new Thermo Scientific™ Dionex™ IonPac™ CS19-4µm Capillary, Analytical, & Guard Column. This high-capacity, high-resolution carboxylate-functionalized column provides excellent resolution of common cations, small...

Dionex™ AC-ER Anion Concentrator for RFIC-ER Thermo Scientific™

Maximize the number of injections between eluent changes when using a Reagent-Free™ ion chromatography with eluent regeneration (RFIC™-ER) system with the Thermo Scientific™ Dionex IonPac AC-ER Anion Concentrator column.

Dionex™ IonPac™ AS15 IC Columns Thermo Scientific™

Determine trace-level concentrations of inorganic anions and low-molecular-weight organic acids in high-purity water matrices with the Thermo Scientific™ Dionex™ IonPac™ AS15 Capillary, Analytical & Guard Columns.

Dionex™ CarboPac™ PA20 IC Columns Thermo Scientific™

Quickly and efficiently separate simple sugars without compromising resolution with Thermo Scientific™ Dionex™ CarboPac™ PA20 Columns. Combined with pulsed amperometric detection (PAD), these strong anion-exchange columns provide high-resolution separations at high pH with no need for...

Dionex™ IonPac™ AS28-Fast-4µm IC Columns Thermo Scientific™

Analyze trace inorganic anions and low molecular weight organic acids using the Thermo Scientific™ Dionex™ IonPac™ AS28-Fast-4µm ion chromatography (IC) columns. Designed specifically for trace level analysis of high purity water from semiconductor and power industries, this column combines the...

Dionex™ IonPac™ AS10 IC Columns Thermo Scientific™

Analyze trace-levels of inorganic anions and organic acids using isocratic or gradient methods with the Thermo Scientific™ Dionex™ IonPac™ AS10 IC Column. Its high capacity permits the analysis of trace-level analytes in high-ionic-strength matrices.

Dionex™ IonPac™ AS4A-SC IC Columns Thermo Scientific™

For fast, isocratic separation of inorganic anions in environmental waters, the Thermo Scientific™ Dionex™ IonPac™ AS4A-SC column was the preferred column for many years. It was first introduced in 1984 and is the specified column in U.S. EPA Method 300.0 (A).

Dionex™ IonPac™ AS3 Analytical & Guard Anion-Exchange Columns Thermo Scientific™

Use newer Thermo Scientific™ Dionex™ IonPac™ AS22 columns as substitutes for Dionex IonPac AS3 Analytical & Guard Anion-Exchange Columns. The Dionex IonPac AS3 is available in limited quantities while supplies last for customers who have established validated methods using this column.

Dionex™ CarboPac™ PA100 IC Columns Thermo Scientific™

Efficiently resolve oligosaccharides released from therapeutic glycoproteins differing in size, charge, branching, and linkage with the Thermo Scientific™ Dionex™ CarboPac™ PA100 Analytical & Guard Columns.

Dionex™ IonPac™ CS5A IC Columns Thermo Scientific™

Determine common transition and lanthanide metals simultaneously in less than 11 minutes with the Thermo Scientific™ Dionex™ IonPac™ CS5A column. This is a high-resolution column designed for accurate determination of transition and lanthanide metals in a variety of sample matrices.