Popular
Applications & Techniques
Shop All Products
Services
Support
Order Status
Sign in
Quick Order
Search
Thermo Fisher Scientific
Search All
Search
Home
Shop All Products
Process Controllers and Analyzers
Process Controllers and Analyzers
A variety of devices and software products designed to analyze, monitor, and regulate industrial procedures and products to ensure compliance to environmental and safety standards.
Read more
Read less
Checkweighers
(7)
Conveyor Belt Scales
(6)
Gamma Density and Level Gauges
(12)
Level Measurement Controllers
(4)
Material Feeders
(4)
Motion Monitoring Systems
(3)
Process Control Software
(2)
Process Data Management Systems
(1)
Process Flow Controllers
(15)
Process Gas and Sulfur Analyzers
(7)
Process Mass Spectrometers
(4)
Process Moisture Analyzers
(1)
Process Transmitters and Transducers
(1)
Weighing Integrators and Controllers
(7)
16 - 30 of 74 results
Filter
Products
(74)
Learn More
(2,395)
Documents & Support
(498)
Product Category
Checkweighers
(7)
Conveyor Belt Scales
(6)
Gamma Density and Level Gauges
(12)
Level Measurement Controllers
(4)
Material Feeders
(4)
Motion Monitoring Systems
(3)
Process Control Software
(2)
Process Data Management Systems
(1)
Process Flow Controllers
(15)
Process Gas and Sulfur Analyzers
(7)
Process Mass Spectrometers
(4)
Process Moisture Analyzers
(1)
Process Transmitters and Transducers
(1)
Weighing Integrators and Controllers
(7)
Show all
Show less
Application
Environmental
(3)
Industrial & Applied Science
(54)
Lab Equipment
(1)
Mass Spectrometry
(5)
Detector Scan Rate
Up to 100 ppm
(1)
Up to 250 ppm (depending on application)
(2)
Up to 300 ppm (depending on application)
(1)
Up to 320 cpm
(2)
Up to 650 ppm
(1)
Accuracy
±0.5 g, micropitch chain; ±1.0 g, nylatrin chain; ±1.5 g, stainless-steel chain (product/speed dependent); 2 standard deviations from mean
(1)
±0.5% based on approved applications and test requirements
(1)
±0.5% to 1% of set rate at 2 sigma, based on approved applications and test requirements
(1)
±1/4% on factory-approved applications
(1)
±50 mg at 3 sigma
(1)
0.250 to 4.0 g
(2)
Approved for OIML MID (e≥0.5g). Accuracy; standard deviation in general < 0.5 g, depending on application.
(1)
Circular: typically ±1%; Rectangular: typically ±2%
(1)
Random error: to OIML R51 International Standards. European MID Standards and Handbook – 44 U.S. standards or better.
Actual accuracy may differ depending upon package weight, speed, stability and roller type.
(2)
Up to +/-0.1 g at 2 sigma (product/speed dependent)
(1)
Show all
Show less
Alarm Contact Rating
Controllers: 20-35-NM-DIN: (1) NO—2 Amp @ 115/230VAC, 3 Amp @ 24VDC; All other models: (2) SPDT—10 Amp @ 115/230VAC, 7 Amp @ 30VDC non-inductive
(1)
Ambient Temperature
−40°C to +60°C
(1)
12 to 30 °C
(1)
12 to 40°C
(2)
12 to 40°C
(2)
12° to 40°C
(1)
Amplifier and Dynamic Range
100 MHz (pulse counting type)
(1)
Analog Inputs
4x inputs (user configurable as 4-20mA or 0-5V)
(1)
Optional 4-20 mÅ DC inputs from density meter for automatic density compensation of ppm S (w/w); Optional 4-20 mÅ DC input from sample flowmeter
(1)
Optional 4-20mÅ DC inputs from density meter for automatic density compensation of ppm S (w/w); Optional 4-20mÅ DC input from sample flowmeter
(1)
Analog Outputs
4-20 mA DC for each stream, up to 2 streams (optional)
(1)
4-20mA DC for each stream, up to 2 streams (optional)
(1)
4x 4-20 mA outputs
(1)
Audit Trails
200 alarm events, 100 different types of alarms
(1)
200 audit events, 60 different types of audits
(2)
User configurable, defaulting to 200 audit events
(2)
User configurable; defaulting to 200 audit events, 60 different types of audits
(1)
Bulk Gas Suitability
H2, N2, Ar, He (plus O2 for dB model)
(1)
Casing/Flanges
Carbon steel (epoxy coated with rust inhibiting primer), 304 stainless steel or 316 stainless steel. All joints are continuously seam welded. Flanges with bolt holes are standard. For other materials, coatings, etc. consult factory for pricing
(1)
Certifications/Compliance
(Built to) NEC Class I, Division 2, Groups B, C
(1)
C/US Class I, Div. 1, Groups C & D; CSA: C/US Class I, Div. 2, Groups C & D; ATEX: II 1 G Ex ia IIB T4 (-40¦ to +80¦C)
(1)
CE, EMC, NEMA 4X/IP65
(1)
Class I Div 2 (Groups and CD), ATEX zone 2 for hazardous area locations, CE, GOST (pending)
(1)
CSA/C-US Class I, Div 1, Groups B, C, D; ambient temperature range of -40°C to +85°C (-40°F to +185°F), temperature code T6 (-40°C to 75’C) T5 (-40°C to 85°C) EN 61326-1: 2013 (Industrial Criteria); FCC 47 CFR Part 15, Subpart B; ICES 003: 2016
(1)
CSA/C-US Class I, Div 1, Groups B, C, D; ambient temperature range of -40°C to +85°C (-40°F to +185°F), temperature code T6 (-40°C to 75°C) T5 (-40°C to 85°C) EN 61326-1: 2013 (Industrial Criteria); FCC 47 CFR Part 15, Subpart B; ICES 003: 2016; Measurement Canada pending
(1)
CSA/C-US Class I, Div 2, Groups C and D (provides
(2)
CSA/C-US Class I, Div 2, Groups C and D hazardous locations; ambient temperature range of -40°C to +85°C, temperature code T3Cl Type 4X enclosure)
(1)
IP65 NEMA 4 metal enclosure (all models) X -Purge: ATEX Zone 1 II2G Ex d px IIC T4 IP65, inert gas used for purge X -Purge: CSA Class I, Div 1 Groups A, B, C, D T4 / Zone 1 AEx d px IIC T4 (pending), inert gas used for purge Z -Purge: ATEX Zone 2 II3G Ex d e pz IIC T4 IP65, inert gas used for purge Z -Purge: CSA Class I, Div 2 Groups A, B, C, D T4 / Zone 2, AEx d pz IIC T4 (pending), inert gas used for purge
(1)
IP66, CE
(1)
NEC Class I, Division 2, Groups B, C & D. T2/T3 & T4 (T4 rating is application dependent)
NEC Class I, Division 1, Groups B, C & D. T2/T3 & T4 (T4 rating is application dependent)
CSA with associated “C/US Mark” Class I, Division 2, Groups B, C & D. T2/T3 & T4 (T4 rating is application dependent)
CSA with associated “C/US Mark” Class I, Division 1, Groups B, C & D. T2/T3 & T4 (T4 rating is application dependent)
ATEX Zone 1 Ex px IIC T3
ATEX Zone 2 Ex pz IIC T3 IECEx Zone 1 Ex px IIC T3
(1)
Tilt Sensor and Controllers: All models: cCSAus, CE
(1)
Show all
Show less
Communication Ports
(2) Serial (2) Ethernet (1) USB
(1)
CPU Board: 2 RS232, 2 Ethernet, 1 Slave USB
(1)
Optional RS-485
(1)
Optional RS-485 serial communication
(1)
RS 232C for printer
(1)
USB, Ethernet, RS-232C, RS-485, 2- and 4-wire multi-drop, additinoal expansion options
(3)
USB, Ethernet, RS-232C, RS-485, 2- and 4-wire multi-drop, additional expansion options
(2)
Communication Protocols
4x user configurable RS232 or RS485
TCP/IP Ethernet
Connect via Modbus for remote access and control of all analyzer functions and data. Connnect with RS485 or TCP/IP.
(1)
Modbus serial RS232/422/485, Siemens 3964R, VGCP and PVGCP
(1)
Modbus serial RS232/422/485, Siemens 3964R, VGCP and PVGCP; optional via protocol converters: Modbus Ethernet TCP/IP and Profibus DP
(2)
Modbus, Siemens 3964, Siemens 3964R, DDE, OPC, VGCP, PVGCP
(1)
TCP/IP encapsulated Modbus and RS-485 Modbus
(2)
CPL
Ch 11.2.1/Ch 11.2.2; Ch 11.2.1M/Ch 11.2.2M (compressibility factors for hydrocarbons), equilibrium pressure
(1)
Current Outputs
4-20 mA isolated self-powered or loop powered into
(1)
Data Memory
2 MB SRAM
(3)
Data storage: 2MB battery backed RAM plus 4 MB non-volatile serial flash
(1)
SRAM, 2 MB, battery-backed
(1)
SRAM, 2MB, battery-backed
(1)
Data Storage
65 days of daily, 35 days of hourly
(2)
User configurable, defaulting to 65 days of daily, 35 days of hourly per meter run
(1)
Depth (English) Cover
12.68 in.
(1)
6.9 in.
(1)
Depth (English) NEMA 4X
16.2 in.
(1)
8.15 in.
(1)
Depth (Metric) Card Cage
270 mm
(1)
Depth (Metric) Cover
175.26 mm
(1)
319.28 mm
(1)
Depth (Metric) NEMA 4X
207.01 mm
(1)
411.5 mm
(1)
Detection Limits
<10 ppt (component dependent)
(1)
0.25 ppm
(1)
1.25% of full scale or 125 ppb (whichever is greater)
(1)
Detection Noise
100 MHz (pulse counting type)
(1)
Detector Type
NaI scintillation detector
(1)
Pulse counting channel electron multiplier
(1)
Pulsed UV Fluorescence (PUVF) with Pyrolyzer for Total Sulfur Measurement
(1)
Pulsed UV Fluorescence (PUVF) with Pyrolyzer for Total Sulfur Measurement1
(2)
Differential Pressure Signal
Up to 6.25-in water column (w.c.) DP (159mm wg) depending on velocity
(1)
Digital Data Communication
AutoCONFIG™ software: Security protected access to all analyzer setup and configuration parameters and all process and diagnostic data. Connect via a standard PC across your Local Area Network. Download 30,000 data records (process and analzer functions), typically up to 24 hours of records (user configurable).
(1)
Dual channel with the following optional configurations; RS-232 Modbus and RS-485 Modbus; Dual channel RS-485 Modbus; TCP/IP encapsulated Modbus and RS-485 Modbus
(2)
Display Type
CANbus
(2)
Color Touch Screen
(6)
Digital
(2)
LCD
(6)
LCD with Backlight
(1)
MODBUS RTU, MODBUS TCP, ETHERNET I/P, PROFINET, PROFIBUS Supports Dual CANbus for Digitizers 10-1000m cable
(1)
Touch Screen
(1)
EMI/RFI
Less than +1% effect on zero/span (26 to 1000MHz at 30V/m) when installed per product installation guidelines
(1)
Enclosure
Cast/machined aluminum with powder-coated epoxy
(1)
Ramsey CL-100 Control: Polystyrene plastic; IP-64: weather tight
(1)
Enclosure Purge
Inert gas @ 60-115 PSI (4-7.7 BAR), 8 SCFM (225L/m) for 9 minutes; purge gas usage minimal after initial purge
(1)
Enclosure Rating
NEMA 4X industrial control enclosure in aluminum or stainless-steel
(1)
NEMA 4X/IP65
(4)
NEMA 4X/IP67
(2)
Enclosure Size
1.6 mm
(5)
1.6 mm, 2 kg
(1)
300 x 250 x 16 mm (H x W xD) (11.81 x 9.84 x 6.3 in.)
(1)
432 x 360 x 184 mm (17 x 14.2 x 7.2 in.)
(1)
687 x 524 x 230 mm (27 x 20.6 x 9.1 in.)
(1)
Fault Contact Rating
Controllers: All models: (1) NO—rated for 2 Amp @
(1)
FCC Compliance
C/US Class I, Div. 1, Groups C & D; CSA: C/US Class I, Div. 2, Groups C & D; ATEX: II 1 G Ex ia IIB T4 (-40¦ to +80¦C)
(1)
Complies with the limits for a Class A computing device with Part 15 of the FCC rules
(1)
CSA/C-US Class I, Div 2, Groups C and D (provides
(1)
Flow Straighteners
3/8 in. Hexagonal cells either Aluminum (3.5 in. Deep), 304 or 316 stainless steel (2.5 in. Deep). Stainless Steel is of welded construction. For high velocities reinforced Flow Straighteners (6 mil. thick, welded every node) are available
(1)
Frequency Response
-3dB at 5Hz (per ISA-S26.4.3.1 Configuration A)
(1)
Gamma Ray Source Type
Cs-137 or Co-60
(1)
Height (English)
10.5 in.
(1)
36.0 in
(1)
7.5 in.
(1)
Height (English) Cover
10.5 in.
(1)
Height (English) NEMA 4X
17.28 in.
(1)
28 in.
(1)
Height (Metric)
0.53 m (1.7 ft)
(1)
190.5 mm
(1)
266.7 mm
(1)
91.5cm
(1)
GP: 1.5 m (5 ft); Ex: 1.8 m (6 ft)
(2)
Height (Metric) Cover
266.7 mm
(1)
Height (Metric) NEMA 4X
438.91 mm
(1)
711.2 mm
(1)
Hertz
50/60 Hz
(3)
Housing
Controller Assembly: 316SS IP66
Detector Assembly: Epoxy coated mild steel or optional stainless steel
Source Housing: Epoxy coated mild steel over lead or optional stainless steel
(1)
Input Power
+5.5 to +16VDC
(1)
10 to 30VDC
(2)
10 VDC to 30 VDC
(1)
10 VDC to 30 VDC
(2)
Controllers: All models: 115/230 VAC, 50/6 0Hz
(1)
Input Power: 90 to 250, 9 to 30VAC; VDC
(1)
Inputs
One 4-20 mA current loop input for flow meter
One 4-20 mA current loop input for temperature
(1)
Two 4 – 20 mA inputs, full scale ± 0.3% over operating temperature range; two 0 – 10 Vdc input, full scale ± 0.3% over operating temperature range; two Digital inputs (DI): provides contact input with internal +5 Vdc wetting voltage; temperature compensation circuitry with 100-ohm Platinum RTD, 3 or 4 wire; full scale ± 0.5°C over operating temperature range
(1)
Up to 3 additional I/O available; Dry contact closure
(1)
Ion Source Type
Atmospheric pressure ionization
(1)
IP Rating
IP66 (dust and watertight)
(2)
IP66 rating (dust and watertight)
(2)
Linearity
Ranges ≥10 ppm: ±2% of full scale, one sample injection per minute; ±1% of full scale, two sample injections per minute
Ranges ≤10 ppm: ±2% of full scale, two sample injections per minute
(1)
±1.0% of full scale
(1)
±2% of full scale, one sample injection per minute2; ±1% of full scale, two sample injections per minute2
(2)
Live Density Input
Thermo Scientific Sarasota liquid density meter, Solartron, UGC, 4-20 mA
(2)
Thermo Scientific Sarasota, Solartron, UGC, 4-20 mA
(1)
Local MMI
Status of all analyzers parameters (e.g., furnace
(2)
Loop Load
3.8VDC + 5ohm (195ohm load at 20mA)
(1)
Lower Detectable Limit
SOLA iQ Liquid, Vapor, CV & Flare 1.25% of full scale or 125 ppb (whichever is greater), defined as 3x standard deviation at low level sample
SOLA iQ Trace 25 ppb, defined as 3x standard deviation at low level sample
(1)
±1.25% of full scale
(1)
Mass Range
1 to 300 amu
(1)
Adjustable, default is 1-150 amu at 1000 eV ion acceleration voltage, (at 500 eV ion acceleration voltage, mass range is 1-300 amu)
(1)
Adjustable, default is 1-150 amu at 1000 eV ion acceleration voltage, (at 750 eV ion acceleration voltage, mass range is 1-200 amu)
(1)
Adjustable, default is 1-150 amu at 1000 eV ion acceleration voltage, (at 750 eV ion acceleration voltage, mass range is 1-200 amu)
(1)
Max. Static Pressure
Circular: carbon steel casing: 6psig (0.27 B) at 325°F (163°C); Rectangular: carbon steel casing: 1psig (0.07 B) at 325°F (163°C)
(1)
Measurement Method
APIMS dB: 1x Triple filter; APIMS Quattro: 4x Triple filter
(1)
Min. Sizes
Circular: 8 in. Dia.; Rectangular: 10 in. per Side
(1)
Mounting Connection
Rear Mount
(2)
Rear mount
(1)
Mounting Hardware
Tilt Sensor: All models: Hanger and two S-hooks included
(1)
Operating Humidity Range
0-95% RH, non-condensing
(4)
0-95%, non-condensing
(1)
Output Capacity
Standard: 4.0 SCFM (supply and exhaust characteristics are balanced to within ±10%); High Pressure: 4 to 8 SCFM possible (dependent on air supply and tubing size)
(1)
Output Power
9 VDC/80 mA
(1)
9VDC/80mÅ
(1)
Output Power: 12VDC on AI board
(1)
Output Signal
Two 4 to 20mA, isolated; 500ohm maximum
(1)
Outputs
Ramsey CL-100 Control: Three (3) SPDT dry contacts rated 5 A at 250 VAC (low, high, overflow); Three (3) SPDT dry contacts rated 5 A at 250 VAC (low, high, overflow); Ramsey Digital C-Level Control: Four (4) SPDT; NO dry contacts rated 0.5 A at 240 VAC; Optional 0-20 mA, 4-20 mA, 20-0 mA or 20-4 mA; Optional RS-485 serial communication; Ramsey GZ-1 Strain Sensor: 1 mV/V excitation
(1)
Package Type
Any, including cartons, bags, cups, bottles, jars, pouches, boxes, etc.
(2)
Cans, jars, containers with flat bottom, without label, open or closed, wet or dry conditions
(1)
Carton, Bag, Can, Jar, Tray
(2)
Cartons, Cans, Bottles, and Pouches
(1)
Power Consumption
Ramsey CL-100 Control: Less than 10 W; 120/240 VAC selectable; -15% to +10%; 48-62 Hz; Ramsey Digital C-Level Control: 110/220 VAC selectable; 15% to +10%; 48-62 Hz; Ramsey GZ-1 Strain Sensor: N/A
(1)
Power Supply
24VDC, 110VAC or 230VAC 50-60 Hz, 10W
(1)
AC Version: 100-240 VAC 50/60 Hz; Power = 17.2 w; DC Version: 20-28 VDC; Power = 12 w
(1)
Power Supply Tolerance
24VDC or 110-230VAC 50/60Hz, 15W
Wide voltage tolerance range (+-10%)
Isolation/Circuit Breaker to be provided by installer
(1)
Precision
≤ 0.1% relative (typical, application dependent)
(2)
At 10 ppm concentration, readings vary by ≤ ±0.5 ppm over 24 hours and ≤ ±1 ppm over 1 month (typical, application dependent)
(1)
Process Connections
316 Stainless steel, 1/4 in. NPTF
(1)
Program Memory
256 MB
(1)
4 MB flash
(1)
4 MB of flash memory
(3)
Program operation: 32MB; Program memory: 16MB Flash;
(1)
Rate
Up to 100 ppm
(1)
Up to 250 ppm (depending on application)
(2)
Up to 300 ppm (depending on application)
(1)
Up to 320 cpm
(2)
Up to 650 ppm
(1)
Up to 700 cans per minute
(1)
Rejects
Air Flipper, Air Bopper
(1)
Air Jet, Air Bopper, Air Flipper
(1)
Air Jet, Air Jet HD, Air Pusher, Air Bopper
(2)
Repeatability
0.05% of span
(1)
± 0.5% of full scale
(1)
Response Time
15 seconds minimum
(1)
Semi-continuous, outputs updated every 1 second, typically 5-6 minutes to 90% of new value (application dependent)
(1)
RS232 Serial Port
Interface for a laptop (facilitates diagnostics and software updates)
(1)
Optional
(2)
Sample Flow Rate
175 mL/min.
(1)
Sample Pressure
Maximum: 70 psig (4.8 bar)