Shop All Real Time PCR Assays

Volume (Metric) Well


Volume (Metric) Working

TrueMark™ Respiratory Panel 2.0 Amplification Control Applied Biosystems™

The TrueMark Respiratory Panel 2.0 Amplification Control contains a linearized multi-target plasmid with target sequences for each respiratory tract microbiota assay on the TrueMark Respiratory Panel 2.0, OpenArray plate and TrueMark Respiratory Panel 2.0, TaqMan array card. The control can be included in respiratory tract microbiota profiling experiments as a positive control for panel-specific amplification.

The plasmid also contains target sequences for TaqMan Universal RNA Spike In/Reverse Transcription (Xeno) Control, TaqMan Universal Extraction Control Organism (B. atrophaeus), and the human RNase P RPPH1 gene. In addition, the plasmid contains target sequences for additional qualified TaqMan assays for respiratory tract microbiota profiling that may be included on custom arrays or cards. Refer to the Respiratory Tract Microbiota Profiling Experiments v2 using TaqMan Array Cards Application Guide or Respiratory Tract Microbiota Profiling Experiments v2 using OpenArray Application Guide for the full assay list.

The TrueMark Respiratory Panel 2.0 Amplification Control is supplied at a concentration of 1 x 105 copies/μL. During real-time PCR, the control can be used as a stand-alone sample to verify assay performance and to help with troubleshooting.

GeneChip™ PrimeView™ Global Gene Expression Profile Assay Applied Biosystems™

The GeneChip PrimeView Global Gene Expression Profile Assay enables expression profiling with an emphasis on established, well annotated content. More than 36,000 transcripts and variants are measured per sample. Sequences used in the design of the array were selected from the RefSeq version 36, UniGene database 219, and full-length human mRNAs from GenBank™.

Note: The PluriTest™ Assay now accepts PrimeView array data from the GeneChip Scanner 3000.

Go to the PluriTest™ Assay ›

Features include:
• Cost-effective global confirmation of pluripotency marker expression
• Simple-to-use online analysis tool
• Published method with over 15,000 samples analyzed
• For use with GeneChip Scanner 3000

About the PluriTest Assay
The PluriTest Assay is a bioinformatics assay that compares the transcriptional profile of a sample to an extensive reference set of >450 cell/tissue types, including 223 hESC lines, 41 iPSC lines, somatic cells, and tissues. The online analysis tool confirms pluripotency marker expression via two separate scores: Pluripotency and Novelty. The Pluripotency Score informs the user on how strongly a model-based pluripotency signature is expressed in the samples analyzed. The Novelty Score indicates the general model fit for a given sample.

More information on the PluriTest Assay >

UK Biobank Axiom™ Array Kit Applied Biosystems™

The UK Biobank Axiom Array was designed by and for thought leaders in the human genetics community for high-throughput, high-value genotyping of large sample cohorts to explore the genetics of complex diseases and translational research with a single comprehensive low-cost solution. The 96-format array plate allows for genome-wide genotyping of large sample collections such as those screened at biobanks, genome centers, and core labs. This array kit includes the 1x96-format array plate, as well as an Axiom 2.0 Reagent Kit and Axiom GeneTitan Consumables Kit.

GWAS
• Intelligent marker selection enables imputation of millions of additional SNPs
• The genomic content module of each array is optimized for specific populations and is customizable to any 1000 Genomes population study by adding additional markers of your choosing

Pharmacogenomic markers
• Markers were selected to represent phases of absorption, distribution, metabolism, and excretion (ADME)

Inflammation and HLA
• Contains markers with evidence for association with autoimmune and inflammation
• Covers variants in genes in the HLA and KIR regions known to be important in immune response

Exome
• Rare, non-synonymous coding SNPs and indels in protein coding regions of the genome
• A majority of variants are rare with minor allele frequency (MAF) <1%
• Newly discovered loss-of-function content
• SNPs and indels identified from a sequencing initiative of 26,000 individuals
• Known disease-causing mutations

eQTLs
• Markers that have known associations to RNA expression traits
• Captures unique eQTLs contained in the NCBI Genotype-Tissue Expression (GTEx) eQTL database, GEUVIDAS project, and several other discovery projects

Human disease
• Alzheimer-s disease, including coverage of ApoE
• Blood phenotypes
• Cancer common variants
• Cardiometabolic

Choose your content
• Order the pre-designed array and customize it with markers of your choice
• Custom markers may be de novo or selected from the Axiom Genomic Database of genotype-tested markers

Please note: Reagent kits do not include plastic consumables required to run the assay on the Beckman Biomek™ FXP Target Prep Express System. Please contact us for a list of required plastic consumables.

TaqMan™ Array Human T-Cell Receptor and CD3 Complex Applied Biosystems™

The Applied Biosystems® TaqMan® Array Human T-Cell Receptor and CD3 Complex 96-well Plate contains 28 assays to T-Cell Receptor and CD3 Complex associated genes and 4 assays to candidate endogenous control genes. All assays are plated in triplicate. Gene Signature Plates are 96-well plates that are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment.

• Affordable; minimum order of three plates; ideal for small, medium or large-sized projects
• Fast delivery; on your bench in days
• Convenient; dried PCR primer and TaqMan® probe sets supplied in a 96- well plate; just add master mix and your sample
• Same TaqMan®Assay Quality, New Format

TaqMan® Array Plates contain the same high quality TaqMan® Gene Expression Assays (PCR primers and TaqMan® probe sets) that have been commercially available for years in a convenient, dried, 96-well format. Extensive tests have found no difference in performance between TaqMan®Assays supplied in the traditional liquid format and assays dried into a TaqMan® Array Plate. Figure 1 shows the results of an experiment comparing the linear range of the two formats, where no difference in performance was observed.

Just Add Master Mix and Sample, and Begin Cycling
Ideal for projects such as validation of microarray and RNAi data, and pathway studies, the plates include just the right amount of TaqMan®Assay in each well: enough for one 20 µl reaction. You can order as few as three Gene Signature Plates, making these an affordable option for many laboratories and minimizing the waste of unused individually purchased TaqMan®Assays. Save a significant amount of time setting up your experiments. Just add master mix and sample, and begin cycling.

Figure 2 is an example Plate Layout with Gene Symbols and Assay IDs

Plate Map Ensures Proper Data Labeling and Easy Re-Ordering
Each pack of TaqMan® Array Plates is shipped with a CD containing the plate configuration map (see Figure 2) along with the details of each TaqMan®Assay. This information is imported into the real-time PCR instrument to enable proper labeling of experimental data and easy access to Assay ID numbers for simple reordering.

Simple to Use
Each TaqMan® Array Plate well contains a single TaqMan®Assay for one 20 µl reaction. The plates can be stored at room temperature or at 4°C. When you are ready to run your assays, simply add PCR master mix and your cDNA sample, seal the plate, and begin cycling on a real-time PCR instrument.

Compatibility
TaqMan® Array Plates have been optimized for use with TaqMan® Gene Expression Master Mix, but are also compatible with TaqMan® Universal PCR Master Mix. For studies using cultured cells, TaqMan® Array Plates are also compatible (and recommended) with the TaqMan® Gene Expression Cells-to-Ct™ Kit. TaqMan® Array Plates must be run on a real-time PCR instrument with 96-well plate capability. The plates have been validated for use on Applied Biosystems® 7000, 7300, 7500 and 7900HT Fast Real-Time PCR Systems using standard 96-well blocks, standard PCR cycling conditions, and 20 µl reaction volumes.

TaqMan™ Array, Human Activation of cAMP-Dependent PKA, Fast 96-well Applied Biosystems™

These 96-well plates are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment. The TaqMan® Array Human Activation of cAMP-Dependent PKA 96-well Plate contains 92 assays to genes associated with the activation of cAMP-Dependent PKA and 4 assays to candidate endogenous control genes.

Ion AmpliSeq™ Transcriptome Mouse Gene Expression Kit Ion Torrent™

The Ion AmpliSeq Transcriptome Mouse Gene Expression Assay allows simultaneous gene expression measurement of over 20,000 mouse RefSeq genes in a single assay. Providing the ability to work directly with low input levels of total RNA, the Ion AmpliSeq Transcriptome Mouse Gene Expression Assay is ideal for those interested in obtaining comprehensive and highly sensitive gene expression measurements from a wide range of RNA sources. This particular kit enables manual library preparation with throughput flexibility. For automated production, see the Ion AmpliSeq Transcriptome Mouse Gene Expression Panel, Chef-Ready Kit.

The Ion AmpliSeq Transcriptome Mouse Gene Expression Assay offers:
• Flexible, straightforward library preparation—start with as little as 10 ng of total RNA from tissues, cells, or other sources
• Fast gene expression profiling with simple workflow—go from RNA to data in <2 days with ~45 minutes of total hands-on time with the automated workflow of the Ion GeneStudio S5 and Ion Chef systems
• A complementary software plug-in for automated sequencing analysis that provides gene quantitation and reporting as well as quality control metrics
• Compatibility with Ion Xpress Barcode adapters, allowing for multiplexed sequencing

Leveraging the speed and simplicity of Ion AmpliSeq technology, this ultrahigh-multiplex PCR enrichment approach enables rapid gene expression profiling with minimal hands-on time. This research method provides a faster, simpler, and lower-cost sequencing method that is highly correlated to whole-transcriptome RNA sequencing.

Straightforward library preparation and multiplex sequencing with manual kit
Starting with as little as 10 ng of total RNA, libraries can be prepared in approximately seven hours with only one hour of hands-on time. Total RNA is first processed with the SuperScript VILO cDNA Synthesis Kit (not included), and the resulting cDNA is amplified using Ion AmpliSeq technology to accurately maintain expression levels of all genes.

The resulting libraries are ready for downstream template preparation using the Ion OneTouch 2 or Ion Chef System and sequencing on the Ion GeneStudio S5 or Ion Proton System. Libraries can be barcoded for multiplexing, providing flexibility, reduced cost, and increased throughput, with the recommended 16 libraries per Ion 550 Chip and 8 libraries per Ion 540 or Ion PI chip. Other multiplexing options are also possible, depending on the experimental design and desired level of sensitivity.

PrimeView™ 16 Global Gene Expression Profile Assay Applied Biosystems™

The PrimeView 16 Global Gene Expression Profile Assay enables expression profiling of 16 samples at a time with an emphasis on established, well-annotated content. More than 36,000 transcripts and variants are measured per sample. Sequences used in the design of the array were selected from the UniGene database 219, RefSeq version 36, and full-length human mRNAs from GenBank™.

Note: The PluriTest™ Assay now accepts PrimeView array data from GeneTitan instruments.

Go to the PluriTest™ Assay ›

Features include:
• Cost-effective global confirmation of pluripotency marker expression
• Simple-to-use online analysis tool
• Published method with over 15,000 samples analyzed
• For use with GeneTitan family of instruments

About the PluriTest Assay
The PluriTest Assay is a bioinformatics assay that compares the transcriptional profile of a sample to an extensive reference set of >450 cell/tissue types, including 223 hESC lines, 41 iPSC lines, somatic cells, and tissues. The online analysis tool confirms pluripotency marker expression via two separate scores: Pluripotency and Novelty. The Pluripotency Score informs the user on how strongly a model-based pluripotency signature is expressed in the samples analyzed. The Novelty Score indicates the general model fit for a given sample.

More information on the PluriTest Assay >

TaqMan™ Array Human PKA Signaling Applied Biosystems™

These 96-well plates are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment. The TaqMan® Array Human PKA Signaling 96-well Plate contains 92 assays to genes associated with PKA signaling and 4 assays to candidate endogenous control genes.

TaqMan™ Array Human Protein Kinase Pathways Applied Biosystems™

The Applied Biosystems® TaqMan® Array Human Protein Kinase Pathways 96-well Plate contains 92 assays to protein kinases and associated genes and 4 assays to candidate endogenous control genes.

The panel of assays in this plate targets kinases from the receptor protein-tyrosine kinase (RPTK) families and from the Serine/Threonine kinase families. Also included, are non-kinase genes involved in signal transduction and mediate protein-protein interaction, transcriptional regulation, neural development and cell adhesion. Gene Signature Plates are 96-well plates that are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment.

• Affordable; minimum order of three plates; ideal for small, medium or large-sized projects
• Fast delivery; on your bench in days
• Convenient; dried PCR primer and TaqMan® probe sets supplied in a 96- well plate; just add master mix and your sample
• Same TaqMan®Assay Quality, New Format

TaqMan® Array Plates contain the same high quality TaqMan® Gene Expression Assays (PCR primers and TaqMan® probe sets) that have been commercially available for years in a convenient, dried, 96-well format. Extensive tests have found no difference in performance between TaqMan®Assays supplied in the traditional liquid format and assays dried into a TaqMan® Array Plate. Figure 1 shows the results of an experiment comparing the linear range of the two formats, where no difference in performance was observed.

Just Add Master Mix and Sample, and Begin Cycling
Ideal for projects such as validation of microarray and RNAi data, and pathway studies, the plates include just the right amount of TaqMan®Assay in each well: enough for one 20 µl reaction. You can order as few as three Gene Signature Plates, making these an affordable option for many laboratories and minimizing the waste of unused individually purchased TaqMan®Assays. Save a significant amount of time setting up your experiments. Just add master mix and sample, and begin cycling.

Figure 2 is an example Plate Layout with Gene Symbols and Assay IDs

Plate Map Ensures Proper Data Labeling and Easy Re-Ordering
Each pack of TaqMan® Array Plates is shipped with a CD containing the plate configuration map (see Figure 2) along with the details of each TaqMan®Assay. This information is imported into the real-time PCR instrument to enable proper labeling of experimental data and easy access to Assay ID numbers for simple reordering.

Simple to Use
Each TaqMan® Array Plate well contains a single TaqMan®Assay for one 20 µl reaction. The plates can be stored at room temperature or at 4°C. When you are ready to run your assays, simply add PCR master mix and your cDNA sample, seal the plate, and begin cycling on a real-time PCR instrument.

Compatibility
TaqMan® Array Plates have been optimized for use with TaqMan® Gene Expression Master Mix, but are also compatible with TaqMan® Universal PCR Master Mix. For studies using cultured cells, TaqMan® Array Plates are also compatible (and recommended) with the TaqMan® Gene Expression Cells-to-Ct™ Kit. TaqMan® Array Plates must be run on a real-time PCR instrument with 96-well plate capability. The plates have been validated for use on Applied Biosystems® 7000, 7300, 7500 and 7900HT Fast Real-Time PCR Systems using standard 96-well blocks, standard PCR cycling conditions, and 20 µl reaction

TaqMan™ Array Human Protein Kinase Panel Applied Biosystems™

The Applied Biosystems® TaqMan® Human Protein Kinase Array is an efficient, easy-to-use micro fluidic card for quantitative gene expression analysis of human protein kinase genes important in drug discovery. This product is designed with TaqMan® Gene Expression Assays arrayed in singletons in 384 wells and is compatible with an upgraded Applied Biosystems 7900HT Fast Real-Time PCR System.

The Human Protein Kinase Array contains assays for 68 human kinases. Fifty-three of the 68 kinases are from receptor protein-tyrosine kinase (RPTK) families: EGFR, InsulinR, PDGFR, VEGFR, FGFR, CCK, NGFR, HGFR, EPHR, AXL, TIE, RYK, DDR, RET, ROS, LTK, ROR and MUSK. The remaining 15 kinases are Ser⁄Thr kinases from the kinase families: CAMKL, IRAK, Lmr, RIPK and STKR. We have also selected assays for 26 classic endogenous, non-kinase genes. These genes are involved in signal transduction and mediate protein-protein interaction, transcriptional regulation, neural development and cell adhesion. This product is sold in packages of 4 cards.

The array is pre-formatted and inventoried, cost-effective, convenient and easy to use without needing expensive robotics. Results are reproducible and consistent across samples, studies, and labs —the same data quality from card-to-card and lot-to-lot — even with different operators.

Axiom™ Genome-Wide CHB 1 Array Plate Applied Biosystems™

Axiom Genome-Wide Population-Optimized Human Arrays are genotyping panels that offer the best genetic coverage of rare and common variants for genome-wide disease association studies.

The Axiom Genome-Wide CHB 1 Array Plate maximizes genomic coverage of common alleles (MAF >5%) of the Han Chinese genome.

Benefits of Axiom Genome-Wide Population-Optimized Arrays
Each array plate was designed to achieve ˜90% genomic coverage (r2 >0.8) in each target population, while covering markers with MAF of 1-5% in areas such as:
• Critical biological categories (e.g., coding SNPs)
• Biological processes (e.g., drug metabolizing genes)
• Disease categories (e.g., cardiovascular disease, cancer, immunity/inflammation, MHC, and CNS)
• Common and rare SNPs and insertions/deletions (indels) from the International HapMap Project, 1000 Genomes Project, and published disease associations
• Genotype-tested genomic content proven to give informative and reliable results
• Markers preselected for coverage in critical biological categories, such as coding SNPs, and biological pathways, such as drug metabolizing or cardiovascular genes
• High sample pass rate, call rate, and reproducibility
• Compatible with the Axiom 2.0 Reagent Kit, GeneTitan™ MC Instrument, automated or manual workflow, and Genotyping Console™ Software

Other Maximum Genome-Wide Coverage Arrays
These array plates are designed to maximize whole-genome coverage of common and rare alleles, including SNPs within 10 kb of genes.
Axiom Genome-Wide CEU 1 Array Plate - The first cost-effective array to maximize coverage of rare variants (MAF >1%) for European populations
Axiom Genome-Wide ASI 1 Array Plate - The first array designed to maximize genomic coverage of rare alleles (MAF >1%) of a consensus East Asian (JPT+CHB) genome
The Axiom Genome-Wide CHB 1 and CHB 2 Array Set Bundle - This set bundle contains the Axiom Genome-Wide CHB 1 Array Plate and the Axiom Genome-Wide CHB 2 Array Plate. The Axiom Genome-Wide CHB 1 Array Plate maximizes genomic coverage of common alleles (MAF >5%) of the Han Chinese genome. The Axiom Genome-Wide CHB 2 Array Plate is designed to target rare variants (MAF 2-5%) as a complement to Axiom Genome-Wide CHB 1 Array Plate
The Axiom Genome-Wide CHB 2 Array Plate - This array is designed to target rare variants (MAF 2-5%) as a complement to Axiom Genome-Wide CHB 1 Array Plate. The Axiom Genome-Wide CHB 1 and CHB 2 Array Set Bundle enables the most comprehensive commercially available genome-wide coverage in CHB populations.The Axiom Genome-Wide CHB 2 Array Plate designed to target rare variants (MAF 2%-5%) can be accessed at 901842.
The Axiom Genome-Wide PanAFR Array Plate Set - The first array to offer pan-African genomic coverage, with ≥90% genetic coverage of common and rare variants (MAF >2%) of the Yoruba (West African) genome and >85% coverage of common and rare variants (MAF >2%) of the Luhya and Maasi (East African) genomes. This array set also offers high genomic coverage (>85%) in admixed populations with West African ancestry.

Please visit our
NetAffx Analysis Center for more information on microarray analysis

Don't see what you're looking for? Learn how to create an Axiom myDesign™ Array Plate tailored for your study.

Required Products
Axiom Analysis Suite
GeneChip Command Console Software
GeneTitan Multi-Channel Instrument

TaqMan™ Array Human Telomere Extension by Telomerase Applied Biosystems™

The Applied Biosystems® TaqMan® Array Human Telomere Extension by Telomerase 96-well Plate contains 28 assays to telomere extension by telomerase associated genes and 4 assays to candidate endogenous control genes. All assays are plated in triplicate. Gene Signature Plates are 96-well plates that are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment.

• Affordable; minimum order of three plates; ideal for small, medium or large-sized projects
• Fast delivery; on your bench in days
• Convenient; dried PCR primer and TaqMan® probe sets supplied in a 96- well plate; just add master mix and your sample
• Same TaqMan®Assay Quality, New Format

TaqMan® Array Plates contain the same high quality TaqMan® Gene Expression Assays (PCR primers and TaqMan® probe sets) that have been commercially available for years in a convenient, dried, 96-well format. Extensive tests have found no difference in performance between TaqMan®Assays supplied in the traditional liquid format and assays dried into a TaqMan® Array Plate. Figure 1 shows the results of an experiment comparing the linear range of the two formats, where no difference in performance was observed.

Just Add Master Mix and Sample, and Begin Cycling
Ideal for projects such as validation of microarray and RNAi data, and pathway studies, the plates include just the right amount of TaqMan®Assay in each well: enough for one 20 µl reaction. You can order as few as three Gene Signature Plates, making these an affordable option for many laboratories and minimizing the waste of unused individually purchased TaqMan®Assays. Save a significant amount of time setting up your experiments. Just add master mix and sample, and begin cycling.

Figure 2 is an example Plate Layout with Gene Symbols and Assay IDs

Plate Map Ensures Proper Data Labeling and Easy Re-Ordering
Each pack of TaqMan® Array Plates is shipped with a CD containing the plate configuration map (see Figure 2) along with the details of each TaqMan®Assay. This information is imported into the real-time PCR instrument to enable proper labeling of experimental data and easy access to Assay ID numbers for simple reordering.

Simple to Use
Each TaqMan® Array Plate well contains a single TaqMan®Assay for one 20 µl reaction. The plates can be stored at room temperature or at 4°C. When you are ready to run your assays, simply add PCR master mix and your cDNA sample, seal the plate, and begin cycling on a real-time PCR instrument.

Compatibility
TaqMan® Array Plates have been optimized for use with TaqMan® Gene Expression Master Mix, but are also compatible with TaqMan® Universal PCR Master Mix. For studies using cultured cells, TaqMan® Array Plates are also compatible (and recommended) with the TaqMan® Gene Expression Cells-to-Ct™ Kit. TaqMan® Array Plates must be run on a real-time PCR instrument with 96-well plate capability. The plates have been validated for use on Applied Biosystems® 7000, 7300, 7500 and 7900HT Fast Real-Time PCR Systems using standard 96-well blocks, standard PCR cycling conditions, and 20 µl reaction volumes.

LSI VetMAX™ Bluetongue Virus Real-Time PCR Kit, BTV1 typing - IAH

Same as Bluetongue Virus BTV1 Typing - IAH Real-Time PCR Kit (BTV1G-IAH)

TaqMan® probes - RNA - duplex - One well reaction

Real-time PCR enables sensitive and specific detection of pathogen nucleic acid in animal samples, allowing for reliable and rapid screening and detection of infected animals.

The LSI VetMAX™ kits include:

• 1 ready-to-use mix that includes a set of oligonucleotides for detection of the target gene OR these separate components that will need to be mixed together: a set of oligonucleotides for the detection of the target gene + a TaqMan® real-time PCR master mix + an RT enzyme (only for RNA kits).
• 1 external positive control of the same nature as the target (inactivated bacteria or virus). Use as a quality control for PCR and/or extraction yield.
• 1 internal positive control (exogenous) to be added at the time of extraction. Use as a quality control for extraction yield.
• A quality control certificate.

For veterinary use only.

Regulatory requirements vary by country; products may not be available in your geographic area.

Biological hazard safety

WARNING! BIOHAZARD. Biological samples such as tissues, body fluids, infectious agents, and blood of humans and other animals have the potential to transmit infectious diseases. All work should be conducted in properly equipped facilities using the appropriate safety equipment (for example, physical containment devices). Safety equipment also may include items for personal protection, such as gloves, coats, gowns, shoe covers, boots, respirators, face shields, safety glasses, or goggles. Individuals should be trained according to applicable regulatory and company/institution requirements before working with potentially biohazardous materials. Follow all applicable local, state/provincial, and/or national regulations. The following references provide general guidelines when handling biological samples in laboratory environment.

U.S. Department of Health and Human Services, Biosafety in Microbiological and Biomedical Laboratories (BMBL), 5th Edition, HHS Publication No. (CDC) 21-1112, Revised December 2009

World Health Organization, Laboratory Biosafety Manual, 3rd Edition, WHO/CDS/CSR/LYO/2004.11

LSI VetMAX™ Mycobacterium tuberculosis Real-Time PCR Kit, complex

Same as TaqVet Mycobacterium tuberculosis Complex Real-Time PCR Kit

TaqMan® probes - DNA - simplex - Two well reaction

Real-time PCR enables sensitive and specific detection of pathogen nucleic acid in animal samples, allowing for reliable and rapid screening and detection of infected animals.

The LSI VetMAX™ kits include:

• 1 ready-to-use mix that includes a set of oligonucleotides for detection of the target gene OR these separate components that will need to be mixed together: a set of oligonucleotides for the detection of the target gene + a TaqMan® real-time PCR master mix + an RT enzyme (only for RNA kits).
• 1 external positive control of the same nature as the target (inactivated bacteria or virus). Use as a quality control for PCR and/or extraction yield.
• 1 internal positive control (exogenous) to be added at the time of extraction. Use as a quality control for extraction yield.
• A quality control certificate.

For veterinary use only.

Regulatory requirements vary by country; products may not be available in your geographic area.

Biological hazard safety

WARNING! BIOHAZARD. Biological samples such as tissues, body fluids, infectious agents, and blood of humans and other animals have the potential to transmit infectious diseases. All work should be conducted in properly equipped facilities using the appropriate safety equipment (for example, physical containment devices). Safety equipment also may include items for personal protection, such as gloves, coats, gowns, shoe covers, boots, respirators, face shields, safety glasses, or goggles. Individuals should be trained according to applicable regulatory and company/institution requirements before working with potentially biohazardous materials. Follow all applicable local, state/provincial, and/or national regulations. The following references provide general guidelines when handling biological samples in laboratory environment.

U.S. Department of Health and Human Services, Biosafety in Microbiological and Biomedical Laboratories (BMBL), 5th Edition, HHS Publication No. (CDC) 21-1112, Revised December 2009

World Health Organization, Laboratory Biosafety Manual, 3rd Edition, WHO/CDS/CSR/LYO/2004.11

TaqMan™ Array, Human Hox Genes, Fast 96-well Applied Biosystems™

These 96-well plates are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment. The TaqMan® Array Human HOX Genes 96-well Plate contains 92 assays to HOX associated genes and 4 assays to candidate endogenous control genes.
Results per page