Flow Cytometry Compensation, Counting and Calibration
Flow Cytometry Compensation, Counting and Calibration
Reagents and kits for flow cytometer instrument calibration, sample compensation beads and kits, cell counting standards, and other reagents needed to set your instrument up.
UltraComp eBeads™ react with antibodies of mouse, rat, and hamster origin, and are immunoglobulin light chain-independent. They are designed for use in compensation with all fluorochromes excited by ultraviolet (355 nm) violet (405 nm), blue (488 nm), green (532 nm), yellow-green (561 nm), and red...
CountBright™ absolute counting beads are a calibrated suspension of microspheres that are brightly fluorescent across a wide range of excitation and emission wavelengths (UV to 635 nm excitation and 385-800 nm emission).
OneComp eBeads react with antibodies of mouse, rat and hamster origin, and are immunoglobulin light chain-independent. The beads are spherical particles that can be stained with individual fluorochrome-conjugated antibodies for use as single-color compensation controls.
Our Flow Cytometry Size Calibration Kit has nonfluorescent particle-size calibration standards that provide a simple, accurate way to determine cell sizes by flow cytometry. The kit contains six suspensions of highly uniform polystyrene microspheres with the following diameters: 1.0 µm, 2.0 µm, 4.
AccuCheck Counting Beads are an efficient single-platform method for absolute cell counts that combines the advantages of direct flow cytometric immunophenotyping with the use of two different fluorescent beads (A and B beads).
The eBioscience Fixation and Permeabilization Kit is designed for use in preparation of living cells for intracellular staining and flow cytometric analysis. A protein transport inhibitor (Brefeldin A) is included for treatment of cells during culture – to cause accumulation of cytokine protein at...
The Flow Cytometry Sub-micron Particle Size Reference Kit provides six sizes of green-fluorescent beads (ranging in diameter from 0.02 µm to 2.0 µm) packaged in individual vials. Each bead is uniform in size, and the green-fluorescent dyes are localized within the bead, which makes the beads...
BrightComp eBeads compensation beads provide a consistent, accurate, and simple-to-use technique for setting flow cytometry compensation when using fluorescent protein-expressing samples.
The Foxp3 Transcription Factor Fixation/Permeabilization Concentrate and Diluent solutions for staining with antibodies to transcription factors and nuclear proteins, such as Foxp3 and Ki-67, as well as cytokines and chemokines.
Molecular Probes™ AlignFlow™ flow cytometry alignment beads are reliable references for aligning, focusing, and calibrating flow cytometers.The 2.5 µm Alignflow™ Flow Cytometry Alignment Beads for UV Lasers are fluorescent-dye infused microspheres that are optimally excitable between 350-370 nm with...
The AbC™ Total Antibody Compensation Bead Kit provides a consistent, accurate, and simple-to-use technique for the setting of flow cytometry compensation when using fluorochrome-conjugated mouse, rat, hamster, or rabbit antibodies with any laser in flow cytometry.
ArC™ Amine Reactive Compensation Bead Kit is a bead-based compensation tool specifically optimized for use with LIVE/DEAD™ Fixable dead cell stain kits. • Ready-to-use control • Eliminates the hassle of heat-treating cells as a control, saving precious sample • Enables accurate and consistent...
123count eBeads are intended for use in absolute counting of cells or other particles by flow cytometry. These are 7 μm microparticles containing encapsulated dyes compatible with blue (488 nm) and violet (405 nm) excitation sources and emitting fluorescence between approximately 500 nm and 750 nm.
Invitrogen Cal-Lyse™ is a lysing solution formulated to enable the lysis of erythrocytes in samples of anticoagulated human peripheral blood. Invitrogen Cal-Lyse™ lysing solution is intended to be used as an aid in the enumeration of leukocytes that have been stained with monoclonal antibodies for...
Molecular Probes™ Cell Sorting Set-up Beads are reliable standards for flow cytometry sorter instrument setup and calibration. The Cell Sorting Set-up Beads approximate the size, emission wavelength, and intensity of many biological samples, and so can be used to calibrate a flow cytometer’s cell...