IC Trap Columns

IC Trap Columns

Columns designed for use with ion chromatography systems and methods. These columns trap eluent contaminants, preventing them from interfering with analytical results.
Read more Read less
1-9 of 9 Products

Dionex™ BorateTrap™ Inline Trap Column Thermo Scientific™

For optimal performance during IC carbohydrate analysis using HPAE-PAD detection, remove borate contamination using the Thermo Scientific™ Dionex™ BorateTrap™ Inline Trap Column. When placed between the eluent pump and the injection valve, the trap no effect on the efficiencies or retention times of...

Dionex™ CR-TC Continuously Regenerated Trap Columns Thermo Scientific™

Remove ionic contaminants from eluents continuously, without the need for offline chemical regeneration. Thermo Scientific™ Dionex™ CR-TC Continuously Regenerated Trap Columns are electrolytically regenerated trap columns specifically designed for Reagent-Free™ ion chromatography (RFIC™) systems.

Dionex™ IonPac™ Anion Analyte Trap Column Thermo Scientific™

The Thermo Scientific™ Dionex IonPac Anion Analyte Trap Column will remove all the analyte anions from a sample in RFIC systems with Eluent Regeneration.

Dionex™ IonPac™ Cation Analyte Trap Column Thermo Scientific™

The Thermo Scientific™ Dionex IonPac Cation Analyte Trap Column contains high-capacity, cation-exchange resin in the hydronium form.

Dionex™ IonPac™ CP Cation Polisher Columns (CP1 Na+, CP2 H+) Thermo Scientific™

Use Thermo Scientific™ Dionex™ IonPac™ CP Cation Polisher Columns (CP1 Na+, CP2 H+) when analyzing anions in matrices that contain high levels of multivalent cations to reduce deposition of contaminants.

Dionex™ CTC Cation Trap Columns Thermo Scientific™

Remove trace cation contaminants from eluents using the Thermo Scientific™ Dionex™ IonPac™ CTC-1 and Dionex IonPac CTC 500 Cation Trap Columns. These high-capacity, low-efficiency, cation-exchange trap columns are installed in the eluent line after the pump prior to the injection valve to prevent...

Dionex™ IonPac™ ATC-HC and ATC-HC 500 Anion Trap Columns Thermo Scientific™

Use Thermo Scientific™ Dionex™ IonPac™ ATC-HC and ATC-HC 500 Anion Trap Columns to strip anionic contaminants from deionized water or RFIC-EG eluents to prevent them from reaching the guard or analytical column. These high-capacity trap columns are designed specifically for use with RFIC-EG systems.

Dionex™ MFC-1 Metal-Free Trap Columns Thermo Scientific™

Packed with a special chelating resin, the Thermo Scientific™ Dionex™ MFC-1 and MFC 500 Metal-Free Trap Columns are used in the eluent line prior to the injection valve to remove transition metals from high-pH eluents.

Dionex™ ATC Anion Trap Columns Thermo Scientific™

Remove trace anion contaminants from hydroxide or borate eluents with the Thermo Scientific™ Dionex™ IonPac™ ATC-3 and Dionex IonPac ATC 500 Anion Trap Columns. These trap columns are installed in the eluent line after the pump prior to the injection valve to prevent spurious peaks and to minimize...