Shop All Protein Standards & Ladders

IEF Marker 3-10 (Invitrogen™)

IEF Marker 3-10 is a ready-to-use protein marker consisting of 13 purified isoforms for the use in IEF applications. The marker works well on all horizontal and vertical one-dimensional IEF gels and can be used in both native and denaturing conditions.

Compare and view all other protein standards and ladders ›

Applications
• Monitoring of separation on IEF gels

SeeBlue™ Pre-stained Protein Standard (Invitrogen™)

SeeBlue Pre-Stained Standard consists of nine polypeptides that resolve into sharp, tight blue bands in the range of 4–250 kDa allowing you to easily monitor protein electrophoresis and western transfer efficiency. The protein standard is supplied in a ready-to-use format for direct loading onto gels; no need to heat, reduce, or add sample buffer prior to use.

Compare and view all other protein standards and ladders ›

Applications
• Monitoring protein migration during SDS-polyacrylamide gel electrophoresis.
• Monitoring protein transfer onto membranes after western blotting
• Sizing of proteins on SDS-polyacrylamide gels and western blots

PageRuler™ Unstained Broad Range Protein Ladder (Thermo Scientific™)

Thermo Scientific PageRuler Unstained Broad Range Protein Ladder is a mixture of 11 proteins (5 to 250 kDa) for use as size standards in protein electrophoresis (SDS-PAGE) and western blotting. The protein ladder is supplied in a ready-to-use format for direct loading onto gels; no need to heat, reduce, or add sample buffer prior to use.

Compare and view all other protein standards and ladders ›

Product features
• Reference bands—the 100, 50, and 20 kDa bands are more intense for easy orientation
• Tagged— each protein in the contains an integral Strep-tag™ II sequence and can be detected on western blots using Strep-Tactin™ conjugates or an antibody against Strep-tag™ II sequence

Applications
• Accurate protein sizing on SDS-polyacrylamide gels and western blots

PeppermintStick™ Phosphoprotein Molecular Weight Standards (Invitrogen™)

PeppermintStick Phosphoprotein Molecular Weight Standards are a mixture of phosphorylated and nonphosphorylated proteins ranging from 14.4 to 116 kDa. Separation by polyacrylamide gel electrophoresis resolves the standard mixture into two phosphorylated and four nonphosphorylated protein bands.

Applications
• Accurate protein sizing on SDS-polyacrylamide gels and western blots.
• Positive and negative controls for detection of phosphorylated proteins, such as the methods provided by our Pro-Q® Diamond phosphoprotein gel stain

Mark12™ Unstained Standard (Invitrogen™)

Mark12 Unstained Standard consists of 12 polypeptides in the range of 2.5–200 kDa. The protein standard is supplied in a ready-to-use format for direct loading onto gels; no need to heat, reduce, or add sample buffer prior to use.

Compare and view all other protein standards and ladders ›

Applications
• Accurate protein sizing on SDS-polyacrylamide gels and western blots

CandyCane™ Glycoprotein Molecular Weight Standards (Invitrogen™)

CandyCane glycoprotein molecular weight standards separate into alternating bands of glycosylated and nonglycosylated proteins during polyacrylamide gel electrophoresis.

Novex™ Sharp Unstained Protein Standard (Invitrogen™)

Novex Sharp Unstained Protein Standard is designed for accurate and convenient molecular weight estimation of proteins during SDS-PAGE and western blotting. The standard consists of a wide range of molecular weight bands consisting of 12 proteins in the range of 3.5–260 kDa. The protein standard is supplied in a ready-to-use format for direct loading onto gels; no need to heat, reduce, or add sample buffer prior to use.

Compare and view all other protein standards and ladders ›

Applications
• Accurate protein sizing on SDS-polyacrylamide gels and western blots

Pierce™ Prestained Protein MW Marker (Thermo Scientific™)

Thermo Scientific Prestained Protein Molecular Weight Marker is a mixture of six blue-stained natural proteins (20 to 120 kDa) for use as size standards in protein electrophoresis (SDS-PAGE). The protein standards are supplied in a ready-to-use format for direct loading onto gels; no need to heat, reduce, or add sample buffer prior to use.

Compare and view all other protein standards and ladders ›

Component proteins: beta-galactosidase (120 kDa), bovine serum albumin (85 kDa), ovalbumin (50 kDa), cardonic anhydrase (35 kDa), beta-lactoglobulin (25 kDa), and lysozyme (20 kDa)

Applications
• Monitoring protein migration during SDS-polyacrylamide gel electrophoresis.
• Monitoring protein transfer onto membranes after western blotting
• Sizing of proteins on SDS-polyacrylamide gels and western blots

PageRuler™ Plus Prestained Protein Ladder, 10 to 250 kDa (Thermo Scientific™)

Thermo Scientific PageRuler Plus Prestained Protein Ladder is a mixture of nine blue-, orange-, and green-stained proteins (10 to 250 kDa) for use as size standards in protein electrophoresis (SDS-PAGE) and western blotting. The protein ladder is supplied in a ready-to-use format for direct loading onto gels; no need to heat, reduce, or add sample buffer prior to use.

Compare and view all other protein standards and ladders ›

Applications
• Monitoring protein migration during SDS-polyacrylamide gel electrophoresis
• Monitoring protein transfer onto membranes after western blotting
• Sizing of proteins on SDS-polyacrylamide gels and western blots

MagicMark™ XP Western Protein Standard (Invitrogen™)

MagicMark XP Western Protein Standard consists of nine recombinant proteins (20–220 kDa), each of which contains an IgG binding site. The IgG binding site binds the primary or secondary antibody used for detection of the target protein, allowing direct visualization of the standard on the western blot. The MagicMark XP Standard is compatible with most western kits and substrates (chemiluminescent, chromogenic, and fluorescent). The protein standard is supplied in a ready-to-use format for direct loading onto gels; no need to heat, reduce, or add sample buffer prior to use.

Compare and view all other protein standards and ladders ›

Applications
• Western blotting: detection of the nine unstained bands via the detection method used for the target protein. Compatible with chemiluminescent substrates and fluorescent secondary antibodies (not recommended for antibodies labeled with fluors in the 500–550 nm channel).
• Protein size estimation: protein sizing on SDS-polyacrylamide gels and on western blot using western blot detection method

Spectra™ Multicolor Broad Range Protein Ladder (Thermo Scientific™)

Thermo Scientific Spectra Multicolor Broad Range Protein Ladder is a 4-color (blue, orange, green, pink) protein standard containing 10 prestained proteins (10 to 260 kDa) for use in gel electrophoresis and western blotting. The protein ladder is supplied in a ready-to-use format for direct loading onto gels; no need to heat, reduce, or add sample buffer prior to use.

Compare and view all other protein standards and ladders ›

Applications
• Monitoring protein migration during SDS-polyacrylamide gel electrophoresis
• Monitoring protein transfer onto membranes after western blotting
• Sizing of proteins on SDS-polyacrylamide gels and western blots

SeeBlue™ Plus2 Pre-stained Protein Standard (Invitrogen™)

SeeBlue Plus2 Pre-Stained Standard contains 10 proteins (4–250 kDa): 8 blue-dyed and 2 with contrasting colors, for easy and quick evaluation of electrophoresis and western transfer efficiency. The protein standard is supplied in a ready-to-use format for direct loading onto gels; no need to heat, reduce, or add sample buffer prior to use.

Compare and view all other protein standards and ladders ›

Applications
• Monitoring protein migration during SDS-polyacrylamide gel electrophoresis
• Monitoring protein transfer onto membranes after western blotting
• Sizing of proteins on SDS-PAGE gels and western blots