Dynabeads IMS Reagents & BeadRetriever Magnetic Bead Processor

Dynabeads™ anti-E. coli O157 (Applied Biosystems™)

Dynabeads® E. coli anti-O157 is a tool for better sample preparation and improved cell culture and immuno-based assays for E. coli O157:H7 in food, feces, water and other environmental samples. Based on well-known and widely used immunomagnetic separation (IMS) technology, Dynabeads® E. coli anti-O157 provides a useful means to selectively capture E. coli O157:H7 and better prepare samples for effective analysis.

With Dynabeads® anti-E. coli O157, you will:

• Isolate and concentrate E. coli O157:H7 from samples in as little as 24 hours
• Improve detection sensitivity in cell culture and immunoassays of samples
• Perform either manual or automated (using the BeadRetriever™ System) separations

Dynabeads™ MAX E. coli O157 Kit (Applied Biosystems™)

Dynabeads® MAX E.Coli O157 provides a powerful sample preparation method to improve PCR detection and quantification of E.Coli O157:H7 in food, feces, water and other environmental samples.
Based on well known and widely used immunomagnetic separation (IMS) technology, Dynabeads® MAX E.Coli O157 provides a selective E.Coli O157:H7 capture step that delivers significant improvements in PCR analytical process time, as well as the sensitivity and consistency of results. With Dynabeads® MAX E.Coli O157, you'll:

• Perform high throughput, rapid, and effective E.Coli O157:H7 sample preparation
• Significantly shorten sample pre-enrichment time
• Improve detection sensitivity in PCR sample analysis
• Significantly reduce overall analysis time
• Can be carried out manually or automated using the BeadRetriever™ System

Dynabeads™ MAX EPEC/VTEC O121 Kit (Applied Biosystems™)

The Dynabeads® MAX EPEC/VTEC O121 Kit allows for the rapid, selective concentration of E. coli O121 serogroup bacteria in food and environmental samples to improve downstream detection via PCR or culture methods.

• Improve detection sensitivity in PCR sample analysis
• Reduce background in selective agar detection
• Perform the method manually or automate using the BeadRetriever™ System

Improve Sensitivity and Reduce Background
Highly specific antibodies attached to paramagnetic beads are incubated with an aliquot of pre-enriched sample. The beads bind and concentrate the target bacteria from non-target organisms. Washing steps help limit the carryover of inhibitors and matrix-associated particulates. These steps combine to improve the sensitivity of PCR-based detection while reducing background for plating methods.

Manual or Automated Processing
The immunomagnetic separation (IMS) steps can be performed manually with magnets and mixers or automated using the BeadRetriever™ System.

Sensitivity
Following the Dynabeads® MAX EPEC/VTEC O121 protocol, the presence or absence of one viable E. coli O121 can be determined in the sample sizes described if this one E. coli cell is able to replicate and is not masked by resident background flora.

NOTE: Lot 1375851 of this product contains only 1 vial of paramagnetic beads (1 mL each) sufficient for 100 reactions. This batch follows a slightly modified protocol (see use instructions in document part number MAN0007304 Revision 1.0).

Dynabeads™ MX2 Mixer (Applied Biosystems™)

The Dynabeads® MX2 Mixer combines Dynabeads® MX Mixer Base (Cat. No. 159-02), Mixer Turret (Cat. No. 159-06), and 8-tube Mixing Wheel (Cat. No. 159-04). Designed for sample tubes ranging from 15 to 27 mm in diameter.

Dynabeads® MX mixers provide continuous gentle motion to obtain optimal binding of Dynabeads® with targets (e.g., cells, proteins, nucleic acids). Variable speed (5-40 rpm). Can be operated in both cold and warm conditions (4-37°C). Inter-changeable heads accommodate different tube sizes and sample volumes.

Dynabeads™ L10 Tubes (Applied Biosystems™)

Flat-sided reusable glass tubes necessary for optimal recovery of cysts/oocysts during magnetic separation with the MPC-1 or MPC-6 magnetic particle concentrators when using Dynabeads® anti-Cryptosporidium or Dynabeads® GC-Combo.

MPC™-6 (Magnetic Particle Concentrator)

The MPC®-6 (Magnetic Particle Concentrator) holds six tubes with variable diameters (10–30 mm). Optimal working volume: 5–15 mL. Magnetic particle concentrators are designed to obtain optimal binding of Dynabeads® with targets (e.g., cells, proteins, and nucleic acids).

Dynabeads™ MAX EPEC/VTEC O45 Kit (Applied Biosystems™)

The Dynabeads® MAX EPEC/VTEC O45 Kit allows for the rapid, selective concentration of E. coli O45 serogroup bacteria in food and environmental samples to improve downstream detection via PCR or culture methods.

• Improve detection sensitivity in PCR sample analysis
• Reduce background in selective agar detection
• Perform the method manually or automate using the BeadRetriever™ System

Improve Sensitivity and Reduce Background
Highly specific antibodies attached to paramagnetic beads are incubated with an aliquot of pre-enriched sample. The beads bind and concentrate the target bacteria from non-target organisms. Washing steps help limit the carryover of inhibitors and matrix-associated particulates. These steps combine to improve the sensitivity of PCR-based detection while reducing background for plating methods.

Manual or Automated Processing
The immunomagnetic separation (IMS) steps can be performed manually with magnets and mixers or automated using the BeadRetriever™ System.

Sensitivity
Following the Dynabeads® MAX EPEC/VTEC O45 protocol, the presence or absence of one viable E. coli O45 can be determined in the sample sizes described if this one E. coli cell is able to replicate and is not masked by resident background flora.

Dynabeads™ anti-Salmonella (Applied Biosystems™)

For the selective enrichment of Salmonella directly from pre-enrichment samples using ImmunoMagnetic Separation. Method can be performed manually or can be automated by using a BeadRetriever™. Performance tested: Meets the requirements of AOAC RI License no.970401

Benefits and features

• Increases Sensitivity and positive isolation rate
• Easy IMS Protocol - 30 minutes from start to finish
• Shelf stable reagent and low start up costs

This Product Contains: Dynabeads® coated with anti-Salmonella antibodies

Sensitivity:
Sensitivity is very high and enables detection of 1 viable organism in 25g of sample or as few as 100 organisms / ml after pre-enrichment.

Dynabeads™ Spot-On™ Slides (Applied Biosystems™)

Treated, single 9 mm well, glass slides for microscopic analysis of oocysts and cysts. This product is used in combination with the Dynabeads® anti-Cryptosporidium and GC-Combo kits.

Dynabeads™ MX MPC™-S Mixing Wheel (Applied Biosystems™)

Attachment for Dynabeads® MX Mixer Base (Cat. No. 159-02). Designed to hold two MPC®-S sample racks (Cat. No. A13346); capacity up to 12 microcentrifuge tubes.

Dynabeads™ MX 12-tube Mixing Wheel (Applied Biosystems™)

Attachment for Dynabeads® MX Mixer Base (Cat. No. 159-02). Designed to hold 12 sample tubes ranging from 1.5 ml (microcentrifuge) to 1.7 mm diameter. Requires use of Mixer Turret (Cat. No. 159-06) to affix to Mixer Base.

Dynabeads™ Rotary Mixer (Applied Biosystems™)

A rotisserie-style mixer providing continuous gentle motion to obtain optimal binding of Dynabeads® with targets (e.g., cells, proteins, and nucleic acids). Inter-changeable rod accommodates different tube sizes and sample volumes. Basic rod designed for 14 X 1.5 ml tubes or 12 X 10-15 ml tubes. Additional rod (Cat. No. 947-02) available for 14 X 30-50 ml tubes.

Dynabeads™ EPEC/VTEC O111 (Applied Biosystems™)

For the rapid selective concentration of E.coli 0111. Method can be performed manually or can be automated by using a BeadRetriever™.

This Product Contains: Dynabeads® coated with anti-E.coli 0111 antibodies

Sensitivity: Sensitivity is very high and enables detection of 1 viable organism in 25g of sample or as few as 100 organisms / ml after pre enrichment

Dynabeads™ EPEC/VTEC O103 (Applied Biosystems™)

For the rapid selective concentration of E.coli 0103. Method can be performed manually or can be automated by using a BeadRetriever™.

This Product Contains: Dynabeads® coated with anti-E.coli 0103 antibodies

Sensitivity: Sensitivity is very high and enables detection of 1 viable organism in 25g of sample or as few as 100 organisms / ml after pre enrichment

Dynabeads™ MX1 Mixer (Applied Biosystems™)

The Dynabeads® MX1 Mixer combines Dynabeads® MX Mixer Base (Cat. No. 159-02), Mixer Turret (Cat. No. 159-06), and 12-tube Mixing Head (Cat. No. 159-03). Designed for sample tubes ranging from 1.5 ml (microcentrifuge) to 1.7 mm diameter.

Dynabeads® MX mixers provide continuous gentle motion to obtain optimal binding of Dynabeads® with targets (e.g., cells, proteins, nucleic acids). Inter-changeable heads accommodate different tube sizes and sample volumes.