Manual: 3730/3730xl TargetSeq Resequencing System Upgrade User Bulletin(Japanese) Manual / Product Insert

  • Version: 04/2006
Catalog #
  • 3730XL(Discontinued)
  • 3730S(Discontinued)

Manual: Applied Biosystems 3730/3730xl DNA Analyzer User Bulletin (Japanese) Manual / Product Insert

  • Version: 03/2006
Catalog #
  • 3730XL(Discontinued)
  • 3730S(Discontinued)

User Guide: Applied Biosystems 3730 3730xL DNA Analyzer Manual / Product Insert

  • Version: 4331468 Rev.G (01Jan2015)
Catalog #
  • 3730XLR(Discontinued)
  • 3730XL(Discontinued)
  • 3730SR(Discontinued)
  • 3730S(Discontinued)

Quick Ref: Variant Reporter Software v1.0 - Procedure for specifying a reference sequence automatically (Japanese) Manual / Product Insert

  • Version: BIZ005-A07060B 2007
Catalog #
  • 4475006
  • 3730XL(Discontinued)
  • 3730S(Discontinued)
  • 310-00-100-120-W-LSG

Manual: GeneMapper Software v4.0 LOHanalysis Getting Started Guide(Japanese) Manual / Product Insert

  • Version: 06/2005
Catalog #
  • 4475073
  • 3730XL(Discontinued)
  • 3730S(Discontinued)
  • 310-00-100-120-W-LSG

Quick Ref: Variant Reporter Software v1.0 - Procedure for creating a reference sequence automatically (Japanese) Manual / Product Insert

  • Version: BIZ-A07060B 2007
Catalog #
  • 4475006
  • 3730XL(Discontinued)
  • 3730S(Discontinued)
  • 310-00-100-120-W-LSG

Manual: GeneMapper Software v4.0 Microsatellite analysis Getting Started Guide(Japanese) Manual / Product Insert

  • Version: 03/2006 Rev B
Catalog #
  • 4475073
  • 3730XL(Discontinued)
  • 3730S(Discontinued)
  • 310-00-100-120-W-LSG

Manual: 3130 Series System Microsatellite Analysis(Japanese) Manual / Product Insert

  • Version: GEA008-103 2004
Catalog #
  • 4475073
  • 3730XL(Discontinued)
  • 3730S(Discontinued)
  • 310-00-100-120-W-LSG

Manual: GeneMapper Software version 3.7 User's Guide(Japanese) Manual / Product Insert

  • Version: 4359413 Rev. B 10/2004
Catalog #
  • 4475073
  • 3730XL(Discontinued)
  • 3730S(Discontinued)
  • 310-00-100-120-W-LSG

Manual: GeneMapper Software v4.0 SNaPshot analysis Getting Started Guide(Japanese) Manual / Product Insert

  • Version: 06/2005
Catalog #
  • 4323151
  • 4475073
  • 4329538(Discontinued)
  • 3730XL(Discontinued)
  • 3730S(Discontinued)
  • 4323155-LSG
  • 4323154-LSG
  • 310-00-100-120-W-LSG

How do I shut off my Applied Biosystems 3730/3730xl DNA Analyzer? Product FAQ

Answer

After performing the short-term or long-term shutdown wizards:

1. Click “Stop All” in the Service Console and wait until all 4 services turn green. Close the program.
2. Go to the Start menu and select Shut Down. On Windows 7, click the Windows icon in the lower left corner of the screen. Click the arrow next to “Sleep” and select “Shut Down”.
3. Click the power button on the instrument.

Step-by-step instructions for the shutdown procedures can be found in the Applied Biosystems 3730/3730xl DNA Analyzers: Shutting Down the Instrument Technical Note (https://www.thermofisher.com/content/dam/LifeTech/Documents/PDFs/3730-Shut-Down-Procedures.pdf) and the Applied Biosystems 3730/3730xl DNA Analyzer Maintenance and Troubleshooting Guide (http://tools.thermofisher.com/content/sfs/manuals/3730SR_3730XLR_4359473_Maint_TroubShoot_UG.pdf).

Find additional tips, troubleshooting help, and resources within our Capillary Electrophoresis Instruments Support Center.

Answer Id: E12725

Was this answer helpful?

Yes No

Thank you for your response

I have a red blinking light on the Applied Biosystems 3730/3730xl DNA Analyzer. What does it mean and how can I fix it? Product FAQ

Answer

A blinking red light on the instrument may indicate that a hardware component has failed or a possible communication disruption has occurred between the instrument and computer. Completely shut down the instrument, wait for 2 minutes, and then start up in the order documented in Applied Biosystems 3730/3730xl DNA Analyzers: Starting Up the Instrument Technical Note (https://www.thermofisher.com/content/dam/LifeTech/Documents/PDFs/3730-Start-Up-Procedures.pdf) or the Applied Biosystems 3730/3730xl DNA Analyzer Getting Started Guide (http://tools.thermofisher.com/content/sfs/manuals/4478016A.pdf).

If the instrument goes from a flashing amber light to red light, one or more of the hardware components has failed the hardware diagnostic and a service call should be opened up.

Find additional tips, troubleshooting help, and resources within our Capillary Electrophoresis Instruments Support Center.

Answer Id: E12742

Was this answer helpful?

Yes No

Thank you for your response

How often should I perform maintenance on my Applied Biosystems 3730/3730xl DNA Analyzer? Product FAQ

Answer

Maintenance tasks on the Applied Biosystems 3730 series DNA Analyzer are broken down into daily, weekly, monthly, and as-needed tasks. For detailed information on the maintenance steps and when to perform them, please refer to the Applied Biosystems 3730/3730xl DNA Analyzers Maintenance Checklist Technical Note (https://www.thermofisher.com/content/dam/LifeTech/Documents/PDFs/3730-Maintenance-Checklist.pdf) or the Applied Biosystems 3730/3730xl DNA Analyzer Maintenance and Troubleshooting Guide (http://tools.thermofisher.com/content/sfs/manuals/3730SR_3730XLR_4359473_Maint_TroubShoot_UG.pdf).

Find additional tips, troubleshooting help, and resources within our Capillary Electrophoresis Instruments Support Center.

Answer Id: E12729

Was this answer helpful?

Yes No

Thank you for your response

How often should the "Cleanup Processed Plates" command be run on the Applied Biosystems 3730 Series DNA Analyzer? Product FAQ

Answer

The Applied Biosystems 3730 Series DNA Analyzer utilizes an Oracle database to store raw data generated by the system. Additionally, sample files extracted from the database are created on the hard drive. Routine maintenance must be performed to ensure that the appropriate database and hard drive space is available for new data; otherwise, new runs cannot be started and error messages will be generated. The "Cleanup Processed Plates" command in the Database Manager pane will allow you to delete all processed run data and processed plate records from the database. Before running this utility, ensure that all runs have been extracted from the database.

This utility does not delete:
- Data files that have already been extracted
- Spectral data and Spectral plate records
- Spatial information

Thermo Fisher Scientific recommends that this procedure be performed every 400–600 runs. If the database gets too full, an error message will advise the database cleanup. Extracted data (typically in the E drive) will also build-up over time and should be archived off of the computer workstation. After archiving, the extracted data should be deleted.

Find additional tips, troubleshooting help, and resources within our Capillary Electrophoresis Instruments Support Center.

Answer Id: E2547

Was this answer helpful?

Yes No

Thank you for your response

How do I turn on my Applied Biosystems 3730/3730xl DNA Analyzer? Product FAQ

Answer

The Applied Biosystems 3730/3730xl DNA Analyzer system includes both the instrument and the computer - you cannot start or restart one without starting the other. Improper boot sequence can lead to communication issues, aborted runs, and possible loss of data. The proper boot sequence is:

1. Turn on the computer and log in as the local administrator.
2. Turn on the power button on the instrument and wait for the green light.
3. Launch the Data Collection Software and wait until all 4 services turn green.

Step-by-step instructions for the start-up procedures can be found in the Applied Biosystems 3730/3730xl DNA Analyzers: Starting Up the Instrument Technical Note (https://www.thermofisher.com/content/dam/LifeTech/Documents/PDFs/3730-Start-Up-Procedures.pdf) and the Applied Biosystems 3730/3730xl DNA Analyzer Getting Started Guide (http://tools.thermofisher.com/content/sfs/manuals/4478016A.pdf).

Find additional tips, troubleshooting help, and resources within our Capillary Electrophoresis Instruments Support Center.

Answer Id: E12723

Was this answer helpful?

Yes No

Thank you for your response

Results per page