Sort By

CCL5 (RANTES) Monoclonal Antibody (R6G9), eBioscience™ (Invitrogen™)

CCL5 (RANTES) Monoclonal Antibody for Western Blot

CCL5 (RANTES) Monoclonal Antibody (VL1), eFluor 660, eBioscience™ (Invitrogen™)

CCL5 (RANTES) Monoclonal Antibody for Flow

Mouse CCL5 (RANTES) Carrier-Free Recombinant Protein, eBioscience™ (Invitrogen™)

Mouse CCL5 (RANTES) Carrier-Free Recombinant Protein for Ctrl, FN

CCL5 (RANTES) Monoclonal Antibody (21445), APC (Invitrogen™)

CCL5 (RANTES) Monoclonal Antibody for Flow

CCL5 (RANTES) Polyclonal Antibody (Invitrogen™)

CCL5 (RANTES) Polyclonal Antibody for Western Blot, ELISA, Neu

CCL5 (RANTES) Monoclonal Antibody (53433) (Invitrogen™)

CCL5 (RANTES) Monoclonal Antibody for ELISA

CCL5 (RANTES) Monoclonal Antibody (21418) (Invitrogen™)

CCL5 (RANTES) Monoclonal Antibody for Western Blot, ELISA, Neu

RANTES Monoclonal Antibody (21445), PE (Invitrogen™)

CCL5 (RANTES) Monoclonal Antibody for Flow

RANTES Monoclonal Antibody (21445), FITC (Invitrogen™)

CCL5 (RANTES) Monoclonal Antibody for Flow

CCL5 (RANTES) Polyclonal Antibody (Invitrogen™)

CCL5 (RANTES) Polyclonal Antibody for Western Blot

RANTES (human) Recombinant Protein (Invitrogen™)

Human CCL5 (RANTES) Recombinant Protein for Western Blot, Ctrl

RANTES (human) Recombinant Protein (Invitrogen™)

Human CCL5 (RANTES) Recombinant Protein for Western Blot, Ctrl

RANTES (human) Recombinant Protein (Invitrogen™)

Human CCL5 (RANTES) Recombinant Protein for Western Blot, Ctrl

CCL5 Monoclonal Antibody (OTI2A7), TrueMAB™ (OriGene)

CCL5 Monoclonal Antibody for Western blot

CCL5 Monoclonal Antibody (OTI2A7), TrueMAB™ (OriGene)

CCL5 Monoclonal Antibody for Western blot

CCL5 Monoclonal Antibody (OTI10G5), TrueMAB™ (OriGene)

CCL5 Monoclonal Antibody for Western blot

CCL5 Monoclonal Antibody (OTI10G5), TrueMAB™ (OriGene)

CCL5 Monoclonal Antibody for Western blot

CCL5 (RANTES) Monoclonal Antibody (VL1) (Invitrogen™)

CCL5 (RANTES) Monoclonal Antibody for Western Blot, IHC (F), IP, ELISA

CCL5 (RANTES) Recombinant Polyclonal Antibody (25HCLC) (Invitrogen™)

CCL5 (RANTES) Recombinant Polyclonal Antibody for Western Blot, IF, ICC, IHC (P)

CCL5 (RANTES) Polyclonal Antibody (Invitrogen™)

CCL5 (RANTES) Polyclonal Antibody for Western Blot, ELISA

CCL5 (RANTES) Monoclonal Antibody (VL-1), Biotin (Invitrogen™)

CCL5 (RANTES) Monoclonal Antibody for Western Blot, ELISA

CCL5 (RANTES) Recombinant Rabbit Monoclonal Antibody (25H14L17) (Invitrogen™)

CCL5 (RANTES) Recombinant Monoclonal Antibody for Western Blot, IHC (P)

Human CCL5 (RANTES) Recombinant Protein (Invitrogen™)

Human CCL5 (RANTES) Recombinant Protein for Western Blot, IP, ELISA, Ctrl

RANTES Recombinant Human Protein (Gibco™)

Recombinant RANTES is a bioactive protein intended for use in cell culture applications. RANTES functions as a chemoattractant for blood monocytes, memory T helper cells and eosinophils. It causes the release of histamine from basophils and activates eosinophils. RANTES is one of the major HIV-suppressive factors produced by CD8+ cells. It functions as one of the natural ligands for the chemokine receptor CCR5 and it suppresses in vitro replication of the R5 strains of HIV-1, which use CCR5 as a coreceptor.

RANTES Rat ProcartaPlex™ Simplex Kit (Invitrogen™)

The Rat RANTES Simplex ProcartaPlex kit measures RANTES protein and is designed to be combinable with other Simplex kits so that you can create your own multiplex panel that utilizes Luminex xMAP technology for protein detection/quantitation. When combining multiple Simplex kits (i.e., when you are not using a pre-configured Multiplex Panel), only one buffer kit (sold separately) is needed for each assay plate regardless of plex size.

ProcartaPlex immunoassays are based on the principles of a sandwich ELISA, using two highly specific antibodies binding to different epitopes of one protein to quantitate up to 80 protein targets simultaneously when using the FLEXMAP 3D or Luminex 200 instrument and up to 50 protein targets when using the MAGPIX instrument. ProcartaPlex assays require as little as 25 µL of plasma or serum, or 50 µL of cell culture supernatant, and just four hours to obtain analyzed results.

Flexible panels—design your own panels with Simplex kits to measure your own array of targets
More results per sample—measure up to 80 protein targets in a single 25–50 µL sample
Well-established Luminex technology—the most referenced multiplexing platform for protein detection and quantitation

The Luminex MagPlex superparamagnetic microsphere beads in the ProcartaPlex assay are internally dyed with precise proportions of red and infrared fluorophores to create 100 spectrally unique signatures that can be identified by the Luminex xMAP detec¬tion systems (Luminex 200, FLEXMAP 3D, and MAGPIX systems). Similar to a sandwich ELISA, the ProcartaPlex assay uses matched antibody pairs to identify the protein of interest. In a ProcartaPlex multiplex assay, each spectrally unique bead is labeled with antibodies specific for a single target protein, and bound proteins are identified with biotinylated antibodies and streptavidin–R-phycoerythrin (RPE). The conjugation of protein-specific antibodies to a distinct bead allows for analysis of multiple targets in a single well.

The most significant difference between a ProcartaPlex assay and ELISA is that the capture antibody in the ProcartaPlex assay is conjugated to a magnetic bead and not adsorbed to the microplate well, so the ProcartaPlex assay reagents are free-floating in the solution. For detection, the Luminex 200 instrument, for example, contains two lasers, one to distinguish the spectral signature of each bead and the second to quantify the amount of RPE fluorescence, which is proportional to the amount of protein present in the sample. ProcartaPlex multiplex assays can profile up to 80 times more target proteins using significantly less sample in the same time that it takes to perform a traditional sandwich ELISA.

ProcartaPlex Simplex kits provide the ability to create your own unique panel . More than 90% of ProcartaPlex Simplex targets can be combined, providing you with superior flexibility when creating your own multiplex panel.

ProcartaPlex Simplex kits are available across six species (human, mouse, rat, nonhuman primate, porcine, and canine). Visit thermofisher.com/procartaplex for more information, including a comprehensive list of individual protein targets.

Reactivity/Species
Rat

Suitable Sample Types
cell culture supernatant, serum, plasma

Sample Volume
Serum, Plasma: 25 µL; CCS: 50 µL

Reported Application
Multiplex Immunoassay

RANTES Rat ELISA Kit (Invitrogen™)

RANTES Rat ELISA Kit for ELISA

RANTES Human ELISA Kit (Invitrogen™)

RANTES Human ELISA Kit for ELISA

RANTES Recombinant Rat Protein (Gibco™)

Recombinant RANTES is a bioactive protein intended for use in cell culture applications. RANTES functions as a chemoattractant for blood monocytes, memory T helper cells and eosinophils. It causes the release of histamine from basophils and activates eosinophils. RANTES is one of the major HIV-suppressive factors produced by CD8+ cells. It functions as one of the natural ligands for the chemokine receptor CCR5 and it suppresses in vitro replication of the R5 strains of HIV-1, which use CCR5 as a coreceptor.

RANTES Mouse ProcartaPlex™ Simplex Kit (Invitrogen™)

The Mouse RANTES Simplex ProcartaPlex kit measures RANTES protein and is designed to be combinable with other Simplex kits so that you can create your own multiplex panel that utilizes Luminex xMAP technology for protein detection/quantitation. When combining multiple Simplex kits (i.e., when you are not using a pre-configured Multiplex Panel), only one buffer kit (sold separately) is needed for each assay plate regardless of plex size.

ProcartaPlex immunoassays are based on the principles of a sandwich ELISA, using two highly specific antibodies binding to different epitopes of one protein to quantitate up to 80 protein targets simultaneously when using the FLEXMAP 3D or Luminex 200 instrument and up to 50 protein targets when using the MAGPIX instrument. ProcartaPlex assays require as little as 25 µL of plasma or serum, or 50 µL of cell culture supernatant, and just four hours to obtain analyzed results.

Flexible panels—design your own panels with Simplex kits to measure your own array of targets
More results per sample—measure up to 80 protein targets in a single 25–50 µL sample
Well-established Luminex technology—the most referenced multiplexing platform for protein detection and quantitation

The Luminex MagPlex superparamagnetic microsphere beads in the ProcartaPlex assay are internally dyed with precise proportions of red and infrared fluorophores to create 100 spectrally unique signatures that can be identified by the Luminex xMAP detec¬tion systems (Luminex 200, FLEXMAP 3D, and MAGPIX systems). Similar to a sandwich ELISA, the ProcartaPlex assay uses matched antibody pairs to identify the protein of interest. In a ProcartaPlex multiplex assay, each spectrally unique bead is labeled with antibodies specific for a single target protein, and bound proteins are identified with biotinylated antibodies and streptavidin–R-phycoerythrin (RPE). The conjugation of protein-specific antibodies to a distinct bead allows for analysis of multiple targets in a single well.

The most significant difference between a ProcartaPlex assay and ELISA is that the capture antibody in the ProcartaPlex assay is conjugated to a magnetic bead and not adsorbed to the microplate well, so the ProcartaPlex assay reagents are free-floating in the solution. For detection, the Luminex 200 instrument, for example, contains two lasers, one to distinguish the spectral signature of each bead and the second to quantify the amount of RPE fluorescence, which is proportional to the amount of protein present in the sample. ProcartaPlex multiplex assays can profile up to 80 times more target proteins using significantly less sample in the same time that it takes to perform a traditional sandwich ELISA.

ProcartaPlex Simplex kits provide the ability to create your own unique panel . More than 90% of ProcartaPlex Simplex targets can be combined, providing you with superior flexibility when creating your own multiplex panel.

ProcartaPlex Simplex kits are available across six species (human, mouse, rat, nonhuman primate, porcine, and canine). Visit thermofisher.com/procartaplex for more information, including a comprehensive list of individual protein targets.

Reactivity/Species
Mouse

Suitable Sample Types
cell culture supernatant, serum, plasma

Sample Volume
Serum, Plasma: 25 µL; CCS: 50 µL

Reported Application
Multiplex Immunoassay

RANTES Human Instant ELISA™ Kit (Invitrogen™)

RANTES Human Instant ELISA™ Kit for ELISA

RANTES Feline ELISA Kit (Invitrogen™)

RANTES Feline ELISA Kit for ELISA

RANTES Mouse ELISA Kit (Invitrogen™)

RANTES Mouse ELISA Kit for ELISA

RANTES Human ProcartaPlex™ Simplex Kit (Invitrogen™)

The Human RANTES Simplex ProcartaPlex kit measures RANTES protein and is designed to be combinable with other Simplex kits so that you can create your own multiplex panel that utilizes Luminex xMAP technology for protein detection/quantitation. When combining multiple Simplex kits (i.e., when you are not using a pre-configured Multiplex Panel), only one buffer kit (sold separately) is needed for each assay plate regardless of plex size.

ProcartaPlex immunoassays are based on the principles of a sandwich ELISA, using two highly specific antibodies binding to different epitopes of one protein to quantitate up to 80 protein targets simultaneously when using the FLEXMAP 3D or Luminex 200 instrument and up to 50 protein targets when using the MAGPIX instrument. ProcartaPlex assays require as little as 25 µL of plasma or serum, or 50 µL of cell culture supernatant, and just four hours to obtain analyzed results.

Flexible panels—design your own panels with Simplex kits to measure your own array of targets
More results per sample—measure up to 80 protein targets in a single 25–50 µL sample
Well-established Luminex technology—the most referenced multiplexing platform for protein detection and quantitation

The Luminex MagPlex superparamagnetic microsphere beads in the ProcartaPlex assay are internally dyed with precise proportions of red and infrared fluorophores to create 100 spectrally unique signatures that can be identified by the Luminex xMAP detec¬tion systems (Luminex 200, FLEXMAP 3D, and MAGPIX systems). Similar to a sandwich ELISA, the ProcartaPlex assay uses matched antibody pairs to identify the protein of interest. In a ProcartaPlex multiplex assay, each spectrally unique bead is labeled with antibodies specific for a single target protein, and bound proteins are identified with biotinylated antibodies and streptavidin–R-phycoerythrin (RPE). The conjugation of protein-specific antibodies to a distinct bead allows for analysis of multiple targets in a single well.

The most significant difference between a ProcartaPlex assay and ELISA is that the capture antibody in the ProcartaPlex assay is conjugated to a magnetic bead and not adsorbed to the microplate well, so the ProcartaPlex assay reagents are free-floating in the solution. For detection, the Luminex 200 instrument, for example, contains two lasers, one to distinguish the spectral signature of each bead and the second to quantify the amount of RPE fluorescence, which is proportional to the amount of protein present in the sample. ProcartaPlex multiplex assays can profile up to 80 times more target proteins using significantly less sample in the same time that it takes to perform a traditional sandwich ELISA.

ProcartaPlex Simplex kits provide the ability to create your own unique panel . More than 90% of ProcartaPlex Simplex targets can be combined, providing you with superior flexibility when creating your own multiplex panel.

ProcartaPlex Simplex kits are available across six species (human, mouse, rat, nonhuman primate, porcine, and canine). Visit thermofisher.com/procartaplex for more information, including a comprehensive list of individual protein targets.

Reactivity/Species
Human

Suitable Sample Types
cell culture supernatant, serum, plasma

Sample Volume
Serum, Plasma: 25 µL; CCS: 50 µL

Reported Application
Multiplex Immunoassay

RANTES Monkey ProcartaPlex™ Simplex Kit (Invitrogen™)

The Non-Human Primate RANTES Simplex ProcartaPlex kit measures RANTES protein and is designed to be combinable with other Simplex kits so that you can create your own multiplex panel that utilizes Luminex xMAP technology for protein detection/quantitation. When combining multiple Simplex kits (i.e., when you are not using a pre-configured Multiplex Panel), only one buffer kit (sold separately) is needed for each assay plate regardless of plex size.

ProcartaPlex immunoassays are based on the principles of a sandwich ELISA, using two highly specific antibodies binding to different epitopes of one protein to quantitate up to 80 protein targets simultaneously when using the FLEXMAP 3D or Luminex 200 instrument and up to 50 protein targets when using the MAGPIX instrument. ProcartaPlex assays require as little as 25 µL of plasma or serum, or 50 µL of cell culture supernatant, and just four hours to obtain analyzed results.

Flexible panels—design your own panels with Simplex kits to measure your own array of targets
More results per sample—measure up to 80 protein targets in a single 25–50 µL sample
Well-established Luminex technology—the most referenced multiplexing platform for protein detection and quantitation

The Luminex MagPlex superparamagnetic microsphere beads in the ProcartaPlex assay are internally dyed with precise proportions of red and infrared fluorophores to create 100 spectrally unique signatures that can be identified by the Luminex xMAP detec¬tion systems (Luminex 200, FLEXMAP 3D, and MAGPIX systems). Similar to a sandwich ELISA, the ProcartaPlex assay uses matched antibody pairs to identify the protein of interest. In a ProcartaPlex multiplex assay, each spectrally unique bead is labeled with antibodies specific for a single target protein, and bound proteins are identified with biotinylated antibodies and streptavidin–R-phycoerythrin (RPE). The conjugation of protein-specific antibodies to a distinct bead allows for analysis of multiple targets in a single well.

The most significant difference between a ProcartaPlex assay and ELISA is that the capture antibody in the ProcartaPlex assay is conjugated to a magnetic bead and not adsorbed to the microplate well, so the ProcartaPlex assay reagents are free-floating in the solution. For detection, the Luminex 200 instrument, for example, contains two lasers, one to distinguish the spectral signature of each bead and the second to quantify the amount of RPE fluorescence, which is proportional to the amount of protein present in the sample. ProcartaPlex multiplex assays can profile up to 80 times more target proteins using significantly less sample in the same time that it takes to perform a traditional sandwich ELISA.

ProcartaPlex Simplex kits provide the ability to create your own unique panel . More than 90% of ProcartaPlex Simplex targets can be combined, providing you with superior flexibility when creating your own multiplex panel.

ProcartaPlex Simplex kits are available across six species (human, mouse, rat, nonhuman primate, porcine, and canine). Visit thermofisher.com/procartaplex for more information, including a comprehensive list of individual protein targets.

Reactivity/Species
Monkey

Suitable Sample Types
cell culture supernatant, serum, plasma

Sample Volume
Serum, Plasma: 25 µL; CCS: 50 µL

Reported Application
Multiplex Immunoassay

RANTES Mouse Instant ELISA™ Kit (Invitrogen™)

RANTES Mouse Instant ELISA™ Kit for ELISA

CCL5 (RANTES) Monoclonal Antibody (947A 1H11), Biotin (Invitrogen™)

CCL5 (RANTES) Monoclonal Antibody for ELISA

RANTES Monoclonal Antibody (947A5G6) (Invitrogen™)

CCL5 (RANTES) Monoclonal Antibody for ELISA

CCL5 (RANTES) Polyclonal Antibody (Invitrogen™)

CCL5 (RANTES) Polyclonal Antibody for Western Blot, IHC (P), ELISA, FN

CCL5 (RANTES) Polyclonal Antibody (Invitrogen™)

CCL5 (RANTES) Polyclonal Antibody for Western Blot, ELISA

CCL5 (RANTES) Polyclonal Antibody (Invitrogen™)

CCL5 (RANTES) Polyclonal Antibody for Western Blot

CCL5 (RANTES) Monoclonal Antibody (53405.111) (Invitrogen™)

CCL5 (RANTES) Monoclonal Antibody for IF, ICC, IA

CCL5 (RANTES) Polyclonal Antibody (Invitrogen™)

CCL5 (RANTES) Polyclonal Antibody for Western Blot

CCL5 (RANTES) Polyclonal Antibody (Invitrogen™)

CCL5 (RANTES) Polyclonal Antibody for ELISA

Human 42-Plex Human ProcartaPlex™ Panel 1, Platinum (Invitrogen™)

Platinum ProcartaPlex™ Immunoassays are our are highest validated bead based Multiplexing assay system for quantificaton of multiple protein biomarkers in a single sample.
Newly developed matrix type specific diluents for plasma and serum enable to overcome matrix effects and assure high performance specifications (e.g spike and dilution recovery results between 70-130%).
Our Platinum ProcartaPlex assays use Luminex™ xMAP technology for the multi-analyte detection of secreted proteins including cytokines, chemokines, growth factors and other proteins. Platinum ProcartaPlex™ assays are subject to the same stringent and robust development and manufacturing as are our extensively validated Platinum and Instant ELISA assays.

Platinum ProcartaPlex Panels are ready-to-use kits and are not combinable with other Platinum ProcartaPlex Simplex kits or kits from different format.

Reactivity/Species
Human

Suitable Sample Types
Serum, Plasma

Sample Volume
Serum, Plasma: 25 µL

Reported Application
Multiplex Immunoassay

Target List
IL-12; Brain-Derived Neurotrophic Factor (BDNF); CCL11 (Eotaxin); CCL3 (MIP-1 alpha); CCL4 (MIP-1 beta); CCL5 (RANTES); CD31 (PECAM-1); CD62P (P-Selectin); CXCL1 (GRO alpha); CXCL10 (IP-10); GM-CSF; HGF; IFN alpha; IFN gamma; IL-1 alpha; IL-1 beta; IL-1 Receptor Antagonist; IL-10; IL-13; IL-15; IL-16; IL-17A; IL-2; IL-20; IL-21; IL-4; IL-5; IL-6; IL-7; IL-8 (CXCL8); IL-9; LIF; OPG; sCD120b (sTNF Receptor II); Stem Cell Factor (SCF); TNF alpha; t-PA; TSLP; VEGF-A; VEGF-D; PDGF-BB; MCP-2

Bead Regions
See product documentation

Assay Range
See product documentation

Assay Sensitivity
See product documentation

Chemokine 9-Plex Human ProcartaPlex™ Panel 1 (Invitrogen™)

The Human Chemokine I 9-plex ProcartaPlex Panel is a preconfigured multiplex immunoassay kit that measures 9 protein targets using Luminex xMAP technology. ProcartaPlex preconfigured panels are supplied with all the necessary reagents to perform the assay and are validated to ensure reproducibility and consistency. These panels are designed for those who need greater validation for longitudinal studies.

ProcartaPlex immunoassays are based on the principles of a sandwich ELISA, using two highly specific antibodies binding to different epitopes of one protein to quantitate all protein targets simultaneously using a Luminex instrument. ProcartaPlex multiplex assays require as little as 25 µL of plasma or serum, or 50 µL of cell culture supernatant, and just four hours to obtain analyzed results.

Reproducible, reliable results—validated as a panel to the highest industry standard, including protein target combinability and cross-reactivity testing
More results per sample—measure multiple protein targets simultaneously in a single 25–50 µL sample
Well-established Luminex technology—the most referenced multiplexing platform for protein detection and quantitation

ProcartaPlex assays utilize Luminex xMAP (multianalyte profiling) technology for the simultaneous detection and quantitation of up to 80 protein targets in a single 25–50 µL sample—from plasma, serum, cell culture supernatants, and other bodily fluids.

The Luminex MagPlex superparamagnetic microsphere beads in the ProcartaPlex assay are internally dyed with precise proportions of red and infrared fluorophores to create 100 spectrally unique signatures that can be identified by the Luminex xMAP detec¬tion systems (Luminex 200, FLEXMAP 3D, and MAGPIX systems). Similar to a sandwich ELISA, the ProcartaPlex assay uses matched antibody pairs to identify the protein of interest. In a multiplexed assay, each spectrally unique bead is labeled with antibodies specific for a single target protein, and bound proteins are identified with biotinylated antibodies and streptavidin–R-phycoerythrin (RPE). The conjugation of protein-specific antibodies to a distinct bead allows for analysis of multiple targets in a single well.

The most significant difference between a ProcartaPlex assay and ELISA is that the capture antibody in the ProcartaPlex assay is conjugated to a magnetic bead and not adsorbed to the microplate well, so the ProcartaPlex assay reagents are free-floating in the solution. For detection, the Luminex 200 instrument, for example, contains two lasers, one to distinguish the spectral signature of each bead and the second to quantify the amount of RPE fluorescence, which is proportional to the amount of protein present in the sample. ProcartaPlex multiplex assays can profile more target proteins using significantly less sample in the same time that it takes to perform a traditional sandwich ELISA.

ProcartaPlex multiplex panels are available in multiple formats across six species (human, mouse, rat, nonhuman primate, porcine, and canine). Visit thermofisher.com/procartaplex for more information and available products.

Reactivity/Species
Human

Suitable Sample Types
cell culture supernatant, serum, plasma

Sample Volume
Serum, Plasma: 25 µL; CCS: 50 µL

Reported Application
Multiplex Immunoassay

Target List
Eotaxin; GRO alpha; IL-8; IP-10; MCP-1; MIP-1 alpha; MIP-1 beta; SDF-1 alpha; RANTES

Bead Regions
Eotaxin: 33; GRO alpha: 61; IL-8: 27; IP-10: 22; MCP-1: 51; MIP-1 alpha: 12; MIP-1 beta: 47; SDF-1 alpha: 13; RANTES: 42

Assay Range
[As determined for Lot 1:] Eotaxin: 0.61-2500 pg/mL; GRO alpha: 2.44-10000 pg/mL; IL-8: 2.44-10000 pg/mL; IP-10: 1.95-8000 pg/mL; MCP-1: 1.22-5000 pg/mL; MIP-1 alpha: 2.14-8750 pg/mL; MIP-1 beta: 6.10-25000 pg/mL; SDF-1 alpha: 17.09-70000 pg/mL; RANTES: 0.61-2500 pg/mL

Assay Sensitivity
[As determined for Lot 1:] Eotaxin: 1.4 pg/mL; GRO alpha: 2.8 pg/mL; IL-8: 1.2 pg/mL; IP-10: 0.3 pg/mL; MCP-1: 0.6 pg/mL; MIP-1 alpha: 1.1 pg/mL; MIP-1 beta: 4.7 pg/mL; SDF-1 alpha: 20.5 pg/mL; RANTES: 0.2 pg/mL

Chemokine 9-Plex Mouse ProcartaPlex™ Panel 1 (Invitrogen™)

The Mouse Chemokine I 9-plex ProcartaPlex Panel is a preconfigured multiplex immunoassay kit that measures 9 protein targets using Luminex xMAP technology. ProcartaPlex preconfigured panels are supplied with all the necessary reagents to perform the assay and are validated to ensure reproducibility and consistency. These panels are designed for those who need greater validation for longitudinal studies.

ProcartaPlex immunoassays are based on the principles of a sandwich ELISA, using two highly specific antibodies binding to different epitopes of one protein to quantitate all protein targets simultaneously using a Luminex instrument. ProcartaPlex multiplex assays require as little as 25 µL of plasma or serum, or 50 µL of cell culture supernatant, and just four hours to obtain analyzed results.

Reproducible, reliable results—validated as a panel to the highest industry standard, including protein target combinability and cross-reactivity testing
More results per sample—measure multiple protein targets simultaneously in a single 25–50 µL sample
Well-established Luminex technology—the most referenced multiplexing platform for protein detection and quantitation

ProcartaPlex assays utilize Luminex xMAP (multianalyte profiling) technology for the simultaneous detection and quantitation of up to 80 protein targets in a single 25–50 µL sample—from plasma, serum, cell culture supernatants, and other bodily fluids.

The Luminex MagPlex superparamagnetic microsphere beads in the ProcartaPlex assay are internally dyed with precise proportions of red and infrared fluorophores to create 100 spectrally unique signatures that can be identified by the Luminex xMAP detec¬tion systems (Luminex 200, FLEXMAP 3D, and MAGPIX systems). Similar to a sandwich ELISA, the ProcartaPlex assay uses matched antibody pairs to identify the protein of interest. In a multiplexed assay, each spectrally unique bead is labeled with antibodies specific for a single target protein, and bound proteins are identified with biotinylated antibodies and streptavidin–R-phycoerythrin (RPE). The conjugation of protein-specific antibodies to a distinct bead allows for analysis of multiple targets in a single well.

The most significant difference between a ProcartaPlex assay and ELISA is that the capture antibody in the ProcartaPlex assay is conjugated to a magnetic bead and not adsorbed to the microplate well, so the ProcartaPlex assay reagents are free-floating in the solution. For detection, the Luminex 200 instrument, for example, contains two lasers, one to distinguish the spectral signature of each bead and the second to quantify the amount of RPE fluorescence, which is proportional to the amount of protein present in the sample. ProcartaPlex multiplex assays can profile more target proteins using significantly less sample in the same time that it takes to perform a traditional sandwich ELISA.

ProcartaPlex multiplex panels are available in multiple formats across six species (human, mouse, rat, nonhuman primate, porcine, and canine). Visit thermofisher.com/procartaplex for more information and available products.

Reactivity/Species
Mouse

Suitable Sample Types
cell culture supernatant, serum, plasma

Sample Volume
Serum, Plasma: 25 µL; CCS: 50 µL

Reported Application
Multiplex Immunoassay

Target List
GRO alpha; IP-10; MCP-1; MCP-3; MIP-1 alpha; MIP-1 beta; MIP-2; RANTES; Eotaxin

Bead Regions
GRO alpha: 43; IP-10: 22; MCP-1: 51; MCP-3: 48; MIP-1 alpha: 47; MIP-1 beta: 72; MIP-2: 55; RANTES: 44; Eotaxin: 62

Assay Range
[As determined for Lot 1:] Gro alpha: 1.7-7000 pg/mL; IP-10: 0.5-2000 pg/mL; MCP-1: 7.3-30000 pg/mL; MCP-3: 0.2-1000 pg/mL; MIP-1 alpha: 0.5-2000 pg/mL; MIP-1 beta: 1.2-5000 pg/mL; MIP-2: 0.7-3000 pg/mL; RANTES: 2.4-10000 pg/mL; Eotaxin: 0.5-2000 pg/mL

Assay Sensitivity
[As determined for Lot 1:] Gro alpha: 0.05 pg/mL; IP-10: 0.26 pg/mL; MCP-1: 3.43 pg/mL; MCP-3: 0.15 pg/mL; MIP-1 alpha: 0.13 pg/mL; MIP-1 beta: 1.16 pg/mL; MIP-2: 0.37 pg/mL; RANTES: 0.35 pg/mL; Eotaxin: 0.01 pg/mL

Eotaxin Recombinant Mouse Protein (Gibco™)

Recombinant mouse eotaxin is a bioactive protein intended for use in cell culture applications. Eotaxin is a member of the PF-4 family of chemokines. Eotaxin plays a role in inducing calcium flux in eosinophils.

Th9/Th17/Th22/Treg Cytokine 15-Plex Mouse ProcartaPlex™ Panel (Invitrogen™)

The Mouse Th9/Th17/Th22/Treg Cytokine 15-plex ProcartaPlex Panel is a preconfigured multiplex immunoassay kit that measures 15 protein targets using Luminex xMAP technology. ProcartaPlex preconfigured panels are supplied with all the necessary reagents to perform the assay and are validated to ensure reproducibility and consistency. These panels are designed for those who need greater validation for longitudinal studies.

ProcartaPlex immunoassays are based on the principles of a sandwich ELISA, using two highly specific antibodies binding to different epitopes of one protein to quantitate all protein targets simultaneously using a Luminex instrument. ProcartaPlex multiplex assays require as little as 25 µL of plasma or serum, or 50 µL of cell culture supernatant, and just four hours to obtain analyzed results.

Reproducible, reliable results—validated as a panel to the highest industry standard, including protein target combinability and cross-reactivity testing
More results per sample—measure multiple protein targets simultaneously in a single 25–50 µL sample
Well-established Luminex technology—the most referenced multiplexing platform for protein detection and quantitation

ProcartaPlex assays utilize Luminex xMAP (multianalyte profiling) technology for the simultaneous detection and quantitation of up to 80 protein targets in a single 25–50 µL sample—from plasma, serum, cell culture supernatants, and other bodily fluids.

The Luminex MagPlex superparamagnetic microsphere beads in the ProcartaPlex assay are internally dyed with precise proportions of red and infrared fluorophores to create 100 spectrally unique signatures that can be identified by the Luminex xMAP detec¬tion systems (Luminex 200, FLEXMAP 3D, and MAGPIX systems). Similar to a sandwich ELISA, the ProcartaPlex assay uses matched antibody pairs to identify the protein of interest. In a multiplexed assay, each spectrally unique bead is labeled with antibodies specific for a single target protein, and bound proteins are identified with biotinylated antibodies and streptavidin–R-phycoerythrin (RPE). The conjugation of protein-specific antibodies to a distinct bead allows for analysis of multiple targets in a single well.

The most significant difference between a ProcartaPlex assay and ELISA is that the capture antibody in the ProcartaPlex assay is conjugated to a magnetic bead and not adsorbed to the microplate well, so the ProcartaPlex assay reagents are free-floating in the solution. For detection, the Luminex 200 instrument, for example, contains two lasers, one to distinguish the spectral signature of each bead and the second to quantify the amount of RPE fluorescence, which is proportional to the amount of protein present in the sample. ProcartaPlex multiplex assays can profile more target proteins using significantly less sample in the same time that it takes to perform a traditional sandwich ELISA.

ProcartaPlex multiplex panels are available in multiple formats across six species (human, mouse, rat, nonhuman primate, porcine, and canine). Visit thermofisher.com/procartaplex for more information and available products.

Reactivity/Species
Mouse

Suitable Sample Types
cell culture supernatant, serum, plasma

Sample Volume
Serum, Plasma: 25 µL; CCS: 50 µL

Reported Application
Multiplex Immunoassay

Target List
IL-10; IL-17A; IL-22; IL-23; IL-27; IL-9; GRO alpha; IP-10; MCP-1; MCP-3; MIP-1 alpha; MIP-1 beta; MIP-2; RANTES; Eotaxin

Bead Regions
IL-10: 13; IL-17A: 52 ; IL-22: 33; IL-23: 37; IL-27: 36; IL-9: 34; GRO alpha: 43; IP-10: 22; MCP-1: 51; MCP-3: 48; MIP-1 alpha: 47; MIP-1 beta: 72; MIP-2: 55; RANTES: 44; Eotaxin: 62

Assay Range
[As determined for Lot 1:] IL-10: 2.4-10000 pg/mL; IL-17A: 1.2-5000 pg/mL; IL-22: 12.2-50000 pg/mL; IL-23: 12.2-50000 pg/mL; IL-27: 2.4-10000 pg/mL; IL-9: 18.3-75000 pg/mL; Gro alpha: 1.7-7000 pg/mL; IP-10: 0.5-2000 pg/mL; MCP-1: 7.3-30000 pg/mL; MCP-3: 0.2-1000 pg/mL; MIP-1 alpha: 0.5-2000 pg/mL; MIP-1 beta: 1.2-5000 pg/mL; MIP-2: 0.7-3000 pg/mL; RANTES: 2.4-10000 pg/mL; Eotaxin: 0.5-2000 pg/mL

Assay Sensitivity
[As determined for Lot 1:] IL-10: 0.69 pg/mL; IL-17A: 0.08 pg/mL; IL-22: 0.24 pg/mL; IL-23: 2.21 pg/mL; IL-27: 0.34 pg/mL; IL-9: 0.28 pg/mL; Gro alpha: 0.05 pg/mL; IP-10: 0.26 pg/mL; MCP-1: 3.43 pg/mL; MCP-3: 0.15 pg/mL; MIP-1 alpha: 0.13 pg/mL; MIP-1 beta: 1.16 pg/mL; MIP-2: 0.37 pg/mL; RANTES: 0.35 pg/mL; Eotaxin: 0.01 pg/mL

6Ckine Recombinant Mouse Protein (Gibco™)

Recombinant 6Ckine is a bioactive protein intended for use in cell culture applications. Recombinant mouse 6Ckine is intended for use in cell culture applications. 6Ckine is a chemokine involved in chemotaxis of specific cell types.

Cytokine & Chemokine Convenience 26-Plex Mouse ProcartaPlex™ Panel 1 (Invitrogen™)

ProcartaPlex™ immunoassays are our ideal solution for assessing multiple protein biomarkers in a single sample. Our ProcartaPlex assays use Luminex ™ xMAP technology for the multi-analyte detection of secreted proteins including cytokines, chemokines, growth factors and other proteins.
ProcartaPlex™ assays are subject to the same stringent and robust development and manufacturing as are our extensively validated Platinum and Instant ELISA kits. Quantitate multiple targets in cell/tissue culture supernatants, serum, and plasma.

Explore our broad portfolio of pre-configurated panels and combinable single analytes.

NOTE: This kit cannot be combined with other ProcartaPlex Simplex or Multiplex Kits.

Reactivity/Species
Mouse

Suitable Sample Types
cell culture supernatant, serum, plasma

Sample Volume
Serum, Plasma: 25 µL; CCS: 50 µL

Reported Application
Multiplex Immunoassay

Target List
IFN gamma; IL-12p70; IL-13; IL-1 beta; IL-2; IL-4; IL-5; IL-6; TNF alpha; GM-CSF; IL-18; IL-10; IL-17A; IL-22; IL-23; IL-27; IL-9; GRO alpha; IP-10; MCP-1; MCP-3; MIP-1 alpha; MIP-1 beta; MIP-2; RANTES; Eotaxin

Bead Regions
See product documentation

Assay Range
See product documentation

Assay Sensitivity
See product documentation

Th9/Th17/Th22 Cytokine 16-Plex Human ProcartaPlex™ Panel 1 (Invitrogen™)

The Human Th9/Th17/Th22 Cytokine I 16-plex ProcartaPlex Panel is a preconfigured multiplex immunoassay kit that measures 16 protein targets using Luminex xMAP technology. ProcartaPlex preconfigured panels are supplied with all the necessary reagents to perform the assay and are validated to ensure reproducibility and consistency. These panels are designed for those who need greater validation for longitudinal studies.

ProcartaPlex immunoassays are based on the principles of a sandwich ELISA, using two highly specific antibodies binding to different epitopes of one protein to quantitate all protein targets simultaneously using a Luminex instrument. ProcartaPlex multiplex assays require as little as 25 µL of plasma or serum, or 50 µL of cell culture supernatant, and just four hours to obtain analyzed results.

Reproducible, reliable results—validated as a panel to the highest industry standard, including protein target combinability and cross-reactivity testing
More results per sample—measure multiple protein targets simultaneously in a single 25–50 µL sample
Well-established Luminex technology—the most referenced multiplexing platform for protein detection and quantitation

ProcartaPlex assays utilize Luminex xMAP (multianalyte profiling) technology for the simultaneous detection and quantitation of up to 80 protein targets in a single 25–50 µL sample—from plasma, serum, cell culture supernatants, and other bodily fluids.

The Luminex MagPlex superparamagnetic microsphere beads in the ProcartaPlex assay are internally dyed with precise proportions of red and infrared fluorophores to create 100 spectrally unique signatures that can be identified by the Luminex xMAP detec¬tion systems (Luminex 200, FLEXMAP 3D, and MAGPIX systems). Similar to a sandwich ELISA, the ProcartaPlex assay uses matched antibody pairs to identify the protein of interest. In a multiplexed assay, each spectrally unique bead is labeled with antibodies specific for a single target protein, and bound proteins are identified with biotinylated antibodies and streptavidin–R-phycoerythrin (RPE). The conjugation of protein-specific antibodies to a distinct bead allows for analysis of multiple targets in a single well.

The most significant difference between a ProcartaPlex assay and ELISA is that the capture antibody in the ProcartaPlex assay is conjugated to a magnetic bead and not adsorbed to the microplate well, so the ProcartaPlex assay reagents are free-floating in the solution. For detection, the Luminex 200 instrument, for example, contains two lasers, one to distinguish the spectral signature of each bead and the second to quantify the amount of RPE fluorescence, which is proportional to the amount of protein present in the sample. ProcartaPlex multiplex assays can profile more target proteins using significantly less sample in the same time that it takes to perform a traditional sandwich ELISA.

ProcartaPlex multiplex panels are available in multiple formats across six species (human, mouse, rat, nonhuman primate, porcine, and canine). Visit thermofisher.com/procartaplex for more information and available products.

Reactivity/Species
Human

Suitable Sample Types
cell culture supernatant, serum, plasma

Sample Volume
Serum, Plasma: 25 µL; CCS: 50 µL

Reported Application
Multiplex Immunoassay

Target List
IL-9; IL-10; IL-17A; IL-21; IL-22; IL-23; IL-27; Eotaxin; GRO-alpha; IL-8; IP-10; MCP-1; MIP-1 alpha; MIP-1 beta; RANTES; SDF-1 alpha

Bead Regions
IL-10: 28; IL-17A: 36; IL-21: 72; IL-22: 76; IL-23: 63; IL-27: 14; IL-9: 52; Eotaxin: 33; GRO-alpha: 61; IL-8: 27; IP-10: 22; MCP-1: 51; MIP-1 alpha: 12; MIP-1 beta: 47; RANTES: 42; SDF-1 alpha: 13

Assay Range
[As determined for Lot 1:] IL-10: 2.44-10000 pg/mL; IL 17A: 2.44-10000 pg/mL; IL-21: 9.77-40000 pg/mL; IL-22: 31.74-130000 pg/mL; IL-23: 14.65-60000 pg/mL; IL-27: 24.41-100000 pg/mL; IL-9: 9.77-40000 pg/mL; Eotaxin: 0.61-2500 pg/mL; GRO-alpha: 2.44-10000 pg/mL; IL-8: 2.44-10000 pg/mL; IP-10: 1.95-8000 pg/mL; MCP-1: 1.22-5000 pg/mL; MIP-1 alpha: 2.14-8750 pg/mL; MIP-1 beta: 6.10-25000 pg/mL; RANTES: 0.61-2500 pg/mL; SDF1-alpha: 17.09-70000 pg/mL

Assay Sensitivity
[As determined for Lot 1:] IL-10: 0.1 pg/mL; IL-17A: 0.1 pg/mL; IL-21: 0.6 pg/mL; IL-22: 8.2 pg/mL; IL-23: 0.9 pg/mL; IL-27: 5.1 pg/mL; IL-9: 0.5 pg; Eotaxin: 1.4 pg/mL; GRO-alpha: 2.8 pg/mL; IL-8: 1.2 pg/mL; IP-10: 0.3 pg/mL; MCP-1: 0.6 pg/mL; MIP-1 alpha: 1.1 pg/mL; MIP-1 beta: 4.7 pg/mL; RANTES: 0.2 pg/mL; SDF1-alpha: 20.5 pg/mL

MCP-1/CCL2 Human Uncoated ELISA Kit (Invitrogen™)

MCP-1/CCL2 Human Uncoated ELISA Kit for ELISA

Eotaxin Recombinant Human Protein (Gibco™)

Recombinant human eotaxin is a bioactive protein intended for use in cell culture applications. Eotaxin is a member of the PF-4 family of chemokines. Eotaxin plays a role in inducing calcium flux in eosinophils.

Cytokine & Chemokine Convenience 34-Plex Human ProcartaPlex™ Panel 1A (Invitrogen™)

ProcartaPlex™ immunoassays are our ideal solution for assessing multiple protein biomarkers in a single sample. Our ProcartaPlex assays use Luminex ™ xMAP technology for the multi-analyte detection of secreted proteins including cytokines, chemokines, growth factors and other proteins.
ProcartaPlex™ assays are subject to the same stringent and robust development and manufacturing as are our extensively validated Platinum and Instant ELISA kits. Quantitate multiple targets in cell/tissue culture supernatants, serum, and plasma.

Explore our broad portfolio of pre-configurated panels and combinable single analytes.

NOTE: This kit cannot be combined with other ProcartaPlex Simplex or Multiplex Kits.

Reactivity/Species
Human

Suitable Sample Types
cell culture supernatant, serum, plasma

Sample Volume
Serum, Plasma: 25 µL; CCS: 50 µL

Reported Application
Multiplex Immunoassay

Target List
Eotaxin/CCL11; GM-CSF; GRO alpha/CXCL1; IFN alpha; IFN gamma; IL-1 beta; IL-1 alpha; IL-1RA; IL-2; IL-4; IL-5; IL-6; IL-7; IL-8/CXCL8; IL-9; IL-10; IL-12 p70; IL-13; IL-15; IL-17A; IL-18; IL-21; IL-22; IL-23; IL-27; IL-31; IP-10/CXCL10; MCP-1/CCL2; MIP-1 alpha/CCL3; MIP-1 beta/CCL4; RANTES/CCL5; SDF1 alpha/CXCL12; TNF alpha; TNF beta/LTA

Bead Regions
See product documentation

Assay Range
See product documentation

Assay Sensitivity
See product documentation

Cytokine & Chemokine 16-Plex Human ProcartaPlex™ Panel 1 (Invitrogen™)

The Human Cytokine & Chemokine 16-plex ProcartaPlex Panel is a preconfigured multiplex immunoassay kit that measures 16 protein targets using Luminex xMAP technology. ProcartaPlex preconfigured panels are supplied with all the necessary reagents to perform the assay and are validated to ensure reproducibility and consistency. These panels are designed for those who need greater validation for longitudinal studies.

ProcartaPlex immunoassays are based on the principles of a sandwich ELISA, using two highly specific antibodies binding to different epitopes of one protein to quantitate all protein targets simultaneously using a Luminex instrument. ProcartaPlex multiplex assays require as little as 25 µL of plasma or serum, or 50 µL of cell culture supernatant, and just four hours to obtain analyzed results.

Reproducible, reliable results—validated as a panel to the highest industry standard, including protein target combinability and cross-reactivity testing
More results per sample—measure multiple protein targets simultaneously in a single 25–50 µL sample
Well-established Luminex technology—the most referenced multiplexing platform for protein detection and quantitation

ProcartaPlex assays utilize Luminex xMAP (multianalyte profiling) technology for the simultaneous detection and quantitation of up to 80 protein targets in a single 25–50 µL sample—from plasma, serum, cell culture supernatants, and other bodily fluids.

The Luminex MagPlex superparamagnetic microsphere beads in the ProcartaPlex assay are internally dyed with precise proportions of red and infrared fluorophores to create 100 spectrally unique signatures that can be identified by the Luminex xMAP detec¬tion systems (Luminex 200, FLEXMAP 3D, and MAGPIX systems). Similar to a sandwich ELISA, the ProcartaPlex assay uses matched antibody pairs to identify the protein of interest. In a multiplexed assay, each spectrally unique bead is labeled with antibodies specific for a single target protein, and bound proteins are identified with biotinylated antibodies and streptavidin–R-phycoerythrin (RPE). The conjugation of protein-specific antibodies to a distinct bead allows for analysis of multiple targets in a single well.

The most significant difference between a ProcartaPlex assay and ELISA is that the capture antibody in the ProcartaPlex assay is conjugated to a magnetic bead and not adsorbed to the microplate well, so the ProcartaPlex assay reagents are free-floating in the solution. For detection, the Luminex 200 instrument, for example, contains two lasers, one to distinguish the spectral signature of each bead and the second to quantify the amount of RPE fluorescence, which is proportional to the amount of protein present in the sample. ProcartaPlex multiplex assays can profile more target proteins using significantly less sample in the same time that it takes to perform a traditional sandwich ELISA.

ProcartaPlex multiplex panels are available in multiple formats across six species (human, mouse, rat, nonhuman primate, porcine, and canine). Visit thermofisher.com/procartaplex for more information and available products.

Reactivity/Species
Human

Suitable Sample Types
cell culture supernatant, serum, plasma

Sample Volume
Serum, Plasma: 25 µL; CCS: 50 µL

Reported Application
Multiplex Immunoassay

Target List
IFN-alpha; IL-1 alpha; IL-1RA; IL-7; IL-15; IL-31; TNF-beta; Eotaxin; GRO-alpha; IL-8; IP-10; MCP-1; MIP-1 alpha; MIP-1 beta; Rantes; SDF-1 alpha

Bead Regions
IFN-alpha: 48; IL-31: 37; IL-15: 65; IL-1 alpha: 62; IL-1RA:38; IL-7: 26; TNF-beta: 54; Eotaxin: 33; GRO-alpha: 61; IL-8: 27; IP-10: 22; MCP-1: 51; MIP-1 alpha: 12; MIP-1 beta: 47; Rantes:42; SDF-1 alpha: 13

Assay Range
[As determined for Lot 1:] IFN alpha: 0.61-2500 pg/mL; IL-15: 3.05-12500 pg/mL; IL-1 alpha: 0.61-2500 pg/mL; IL-1RA: 34.18-140000 pg/mL; IL-7: 0.61-2500 pg/mL; TNF-beta: 6.10-25000 pg/mL; IL-31: 19.53-80000 pg/mL; Eotaxin: 0.61-2500 pg/mL; GRO-alpha: 2.44-10000 pg/mL; IL-8: 2.44-10000 pg/mL; IP-10: 1.95-8000 pg/mL; MCP-1: 1.22-5000 pg/mL; MIP-1 alpha: 2.14-8750 pg/mL; MIP-1 beta: 6.10-25000 pg/mL; Rantes: 0.61-2500 pg/mL; SDF1-alpha: 17.09-70000 pg/mL

Assay Sensitivity
[As determined for Lot 1:] IFN alpha: 0.2 pg/mL; IL-15: 1.1 pg/mL; IL-1 alpha: 0.1 pg/mL; IL-1RA: 17.8 pg/mL; IL-7: 0.2 pg/mL; TNF-beta: 1.6 pg/mL; IL-31: 3.3 pg/mL; Eotaxin: 1.4 pg/mL; GRO-alpha: 2.8 pg/mL; IL-8: 1.2 pg/mL; IP-10: 0.3 pg/mL; MCP-1: 0.6 pg/mL; MIP-1 alpha: 1.1 pg/mL; MIP-1 beta: 4.7 pg/mL; Rantes: 0.2 pg/mL; SDF1-alpha: 20.5 pg/mL

MCP-1/CCL2 Human Uncoated ELISA Kit with Plates (Invitrogen™)

MCP-1/CCL2 Human Uncoated ELISA Kit with Plates for ELISA

CCL4 (MIP-1 beta) Human Uncoated ELISA Kit with Plates (Invitrogen™)

CCL4 (MIP-1 beta) Human Uncoated ELISA Kit with Plates for ELISA

TARC Recombinant Rabbit Monoclonal Antibody (B22H33L5) (Invitrogen™)

TARC Recombinant Monoclonal Antibody for Western Blot, IHC (P)

CCL4 (MIP-1 beta) Human Uncoated ELISA Kit (Invitrogen™)

CCL4 (MIP-1 beta) Human Uncoated ELISA Kit for ELISA

MIP-3 beta Human Uncoated ELISA Kit with Plates (Invitrogen™)

MIP-3 beta Human Uncoated ELISA Kit with Plates for ELISA