Sort By

Insulin Rat ELISA Kit (Invitrogen™)

Insulin Rat ELISA Kit for ELISA

C-Peptide Human ELISA Kit (Invitrogen™)

C-Peptide Human ELISA Kit

Iso-Insulin Human Instant ELISA™ Kit (Invitrogen™)

Iso-Insulin Human Instant ELISA™ Kit for ELISA

Insulin Human ELISA Kit (Invitrogen™)

Insulin Human ELISA Kit for ELISA

Insulin Mouse ELISA Kit (Invitrogen™)

Insulin Mouse ELISA Kit for ELISA

Insulin Human ProcartaPlex™ Simplex Kit (Invitrogen™)

The Human Insulin Simplex ProcartaPlex kit measures insulin protein and is designed to be combinable with other Simplex kits so that you can create your own multiplex panel that utilizes Luminex xMAP technology for protein detection/quantitation. When combining multiple Simplex kits (i.e., when you are not using a pre-configured Multiplex Panel), only one buffer kit (sold separately) is needed for each assay plate regardless of plex size.

ProcartaPlex immunoassays are based on the principles of a sandwich ELISA, using two highly specific antibodies binding to different epitopes of one protein to quantitate up to 80 protein targets simultaneously when using the FLEXMAP 3D or Luminex 200 instrument and up to 50 protein targets when using the MAGPIX instrument. ProcartaPlex assays require as little as 25 µL of plasma or serum, or 50 µL of cell culture supernatant, and just four hours to obtain analyzed results.

Flexible panels—design your own panels with Simplex kits to measure your own array of targets
More results per sample—measure up to 80 protein targets in a single 25–50 µL sample
Well-established Luminex technology—the most referenced multiplexing platform for protein detection and quantitation

The Luminex MagPlex superparamagnetic microsphere beads in the ProcartaPlex assay are internally dyed with precise proportions of red and infrared fluorophores to create 100 spectrally unique signatures that can be identified by the Luminex xMAP detec¬tion systems (Luminex 200, FLEXMAP 3D, and MAGPIX systems). Similar to a sandwich ELISA, the ProcartaPlex assay uses matched antibody pairs to identify the protein of interest. In a ProcartaPlex multiplex assay, each spectrally unique bead is labeled with antibodies specific for a single target protein, and bound proteins are identified with biotinylated antibodies and streptavidin–R-phycoerythrin (RPE). The conjugation of protein-specific antibodies to a distinct bead allows for analysis of multiple targets in a single well.

The most significant difference between a ProcartaPlex assay and ELISA is that the capture antibody in the ProcartaPlex assay is conjugated to a magnetic bead and not adsorbed to the microplate well, so the ProcartaPlex assay reagents are free-floating in the solution. For detection, the Luminex 200 instrument, for example, contains two lasers, one to distinguish the spectral signature of each bead and the second to quantify the amount of RPE fluorescence, which is proportional to the amount of protein present in the sample. ProcartaPlex multiplex assays can profile up to 80 times more target proteins using significantly less sample in the same time that it takes to perform a traditional sandwich ELISA.

ProcartaPlex Simplex kits provide the ability to create your own unique panel . More than 90% of ProcartaPlex Simplex targets can be combined, providing you with superior flexibility when creating your own multiplex panel.

ProcartaPlex Simplex kits are available across six species (human, mouse, rat, nonhuman primate, porcine, and canine). Visit thermofisher.com/procartaplex for more information, including a comprehensive list of individual protein targets.

Reactivity/Species
Human

Suitable Sample Types
cell culture supernatant, serum, plasma

Sample Volume
Serum, Plasma: 25 µL; CCS: 50 µL

Reported Application
Multiplex Immunoassay

C-peptide Human ProcartaPlex™ Simplex Kit (Invitrogen™)

The Human C-peptide Simplex ProcartaPlex kit measures C-peptide protein and is designed to be combinable with other Simplex kits so that you can create your own multiplex panel that utilizes Luminex xMAP technology for protein detection/quantitation. When combining multiple Simplex kits (i.e., when you are not using a pre-configured Multiplex Panel), only one buffer kit (sold separately) is needed for each assay plate regardless of plex size.

ProcartaPlex immunoassays are based on the principles of a sandwich ELISA, using two highly specific antibodies binding to different epitopes of one protein to quantitate up to 80 protein targets simultaneously when using the FLEXMAP 3D or Luminex 200 instrument and up to 50 protein targets when using the MAGPIX instrument. ProcartaPlex assays require as little as 25 µL of plasma or serum, or 50 µL of cell culture supernatant, and just four hours to obtain analyzed results.

Flexible panels—design your own panels with Simplex kits to measure your own array of targets
More results per sample—measure up to 80 protein targets in a single 25–50 µL sample
Well-established Luminex technology—the most referenced multiplexing platform for protein detection and quantitation

The Luminex MagPlex superparamagnetic microsphere beads in the ProcartaPlex assay are internally dyed with precise proportions of red and infrared fluorophores to create 100 spectrally unique signatures that can be identified by the Luminex xMAP detec¬tion systems (Luminex 200, FLEXMAP 3D, and MAGPIX systems). Similar to a sandwich ELISA, the ProcartaPlex assay uses matched antibody pairs to identify the protein of interest. In a ProcartaPlex multiplex assay, each spectrally unique bead is labeled with antibodies specific for a single target protein, and bound proteins are identified with biotinylated antibodies and streptavidin–R-phycoerythrin (RPE). The conjugation of protein-specific antibodies to a distinct bead allows for analysis of multiple targets in a single well.

The most significant difference between a ProcartaPlex assay and ELISA is that the capture antibody in the ProcartaPlex assay is conjugated to a magnetic bead and not adsorbed to the microplate well, so the ProcartaPlex assay reagents are free-floating in the solution. For detection, the Luminex 200 instrument, for example, contains two lasers, one to distinguish the spectral signature of each bead and the second to quantify the amount of RPE fluorescence, which is proportional to the amount of protein present in the sample. ProcartaPlex multiplex assays can profile up to 80 times more target proteins using significantly less sample in the same time that it takes to perform a traditional sandwich ELISA.

ProcartaPlex Simplex kits provide the ability to create your own unique panel . More than 90% of ProcartaPlex Simplex targets can be combined, providing you with superior flexibility when creating your own multiplex panel.

ProcartaPlex Simplex kits are available across six species (human, mouse, rat, nonhuman primate, porcine, and canine). Visit thermofisher.com/procartaplex for more information, including a comprehensive list of individual protein targets.

Reactivity/Species
Human

Suitable Sample Types
cell culture supernatant, serum, plasma

Sample Volume
Serum, Plasma: 25 µL; CCS: 50 µL

Reported Application
Multiplex Immunoassay

AKT1 (Phospho) [pS473] Human ELISA Kit, Ultrasensitive (Invitrogen™)

AKT1 (Phospho) [pS473] Human ELISA Kit, Ultrasensitive for ELISA

AKT (Phospho) [pS473] Human ELISA Kit (Invitrogen™)

AKT (Phospho) [pS473] Human ELISA Kit for ELISA

AKT (Phospho) [pT308] Human ELISA Kit (Invitrogen™)

AKT (Phospho) [pT308] Human ELISA Kit for ELISA

IGF-1 Mouse ELISA Kit (Invitrogen™)

IGF-1 Mouse ELISA Kit for ELISA

IR beta Human ELISA Kit (Invitrogen™)

IR beta Human ELISA Kit for ELISA

IGF-2 Mouse ELISA Kit (Invitrogen™)

IGF-2 Mouse ELISA Kit for ELISA

IR (Phospho) [pY1158] Human ELISA Kit (Invitrogen™)

IR (Phospho) [pY1158] Human ELISA Kit for ELISA

Metabolism/Obesity 9-Plex Human ProcartaPlex™ Panel 2 (Invitrogen™)

The Human Metabolism II 9-plex ProcartaPlex Panel is a preconfigured multiplex immunoassay kit that measures 9 protein targets using Luminex xMAP technology. ProcartaPlex preconfigured panels are supplied with all the necessary reagents to perform the assay and are validated to ensure reproducibility and consistency. These panels are designed for those who need greater validation for longitudinal studies.

ProcartaPlex immunoassays are based on the principles of a sandwich ELISA, using two highly specific antibodies binding to different epitopes of one protein to quantitate all protein targets simultaneously using a Luminex instrument. ProcartaPlex multiplex assays require as little as 25 µL of plasma or serum, or 50 µL of cell culture supernatant, and just four hours to obtain analyzed results.

Reproducible, reliable results—validated as a panel to the highest industry standard, including protein target combinability and cross-reactivity testing
More results per sample—measure multiple protein targets simultaneously in a single 25–50 µL sample
Well-established Luminex technology—the most referenced multiplexing platform for protein detection and quantitation

ProcartaPlex assays utilize Luminex xMAP (multianalyte profiling) technology for the simultaneous detection and quantitation of up to 80 protein targets in a single 25–50 µL sample—from plasma, serum, cell culture supernatants, and other bodily fluids.

The Luminex MagPlex superparamagnetic microsphere beads in the ProcartaPlex assay are internally dyed with precise proportions of red and infrared fluorophores to create 100 spectrally unique signatures that can be identified by the Luminex xMAP detec¬tion systems (Luminex 200, FLEXMAP 3D, and MAGPIX systems). Similar to a sandwich ELISA, the ProcartaPlex assay uses matched antibody pairs to identify the protein of interest. In a multiplexed assay, each spectrally unique bead is labeled with antibodies specific for a single target protein, and bound proteins are identified with biotinylated antibodies and streptavidin–R-phycoerythrin (RPE). The conjugation of protein-specific antibodies to a distinct bead allows for analysis of multiple targets in a single well.

The most significant difference between a ProcartaPlex assay and ELISA is that the capture antibody in the ProcartaPlex assay is conjugated to a magnetic bead and not adsorbed to the microplate well, so the ProcartaPlex assay reagents are free-floating in the solution. For detection, the Luminex 200 instrument, for example, contains two lasers, one to distinguish the spectral signature of each bead and the second to quantify the amount of RPE fluorescence, which is proportional to the amount of protein present in the sample. ProcartaPlex multiplex assays can profile more target proteins using significantly less sample in the same time that it takes to perform a traditional sandwich ELISA.

ProcartaPlex multiplex panels are available in multiple formats across six species (human, mouse, rat, nonhuman primate, porcine, and canine). Visit thermofisher.com/procartaplex for more information and available products.

Reactivity/Species
Human

Suitable Sample Types
cell culture supernatant, serum, plasma

Sample Volume
Serum, Plasma: 25 µL; CCS: 50 µL

Reported Application
Multiplex Immunoassay

Target List
C-peptide; Cortisol; FGF-23; GLP-1; Ghrelin; Insulin; PYY; Leptin; Resisitin

Bead Regions
C-peptide: 56; Cortisol: 12; FGF-23: 54; GLP-1: 21; Ghrelin: 13; Insulin: 29; PYY: 30; Leptin: 45; Resisitin: 39

Assay Range
[As determined for Lot 1:] C-peptide: 24-100000 pg/mL; Cortisol: 0.49-2000 ng/mL; FGF-23: 24-100000 pg/mL; GLP-1: 0.98-4000 pg/mL; Ghrelin: 24-100000 pg/mL; Insulin: 2.0-8000 ng/mL; PYY: 20-80000 pg/mL; Leptin: 19.31-79100 pg/mL; Resisitin: 5.74-23500 pg/mL

Assay Sensitivity
[As determined for Lot 1:] C-peptide: 0.09 ng/mL; Cortisol: 0.29 ng/mL; FGF-23: 24 pg/mL; GLP-1: 0.40 pg/mL; Ghrelin: 18 pg/mL; Insulin: 0.4 ng/mL; PYY: 10 pg/mL; Leptin: 2.0 pg/mL; Resisitin: 0.8 pg/mL