Sort By
Genomics and proteomics search results

Thermo Scientific Aegis5-14 Single-Use BioProcess Container (BPC), with 2 ports, 2D (Thermo Scientific™)

The 100 mL Thermo Scientific™ Labtainer BPC is composed of Thermo Scientific Aegis5-14 film, a single-web, five-layer, animal-origin free film. This BPC includes 2 probe ports (Luer lock connections).

Features:

• All BPCs are constructed in an ISO 7 (Class 10,000) cleanroom, which complies with cGMP standards.
• Manufactured with industry-leading Aegis5-14 film
• C-flex tubing that can be used with tubing welder and various connection options
• Flexible and economic solution to update or increase your bioreactor capacity
• Suitable for both suspension and adherent cultures
• Configurable to meet your process needs, including options for single-use sensing (DO, pH, and pressure)

Customize standard BPC systems for optimized single-use technology

Choose from a large component library – with over 2,000 unique components that include:

• Fittings—straight, reducing, elbow, T-style, X-style, and cross-style.
• Connectors—quick connectors/disconnectors, aseptic connectors and disconnectors, steam-to and steam-through connectors.
• Filters—used for bioburden reduction; sterilization grade filters and gas filters.
• Tubing—thermoplastic elastomers, platinum-cured silicone.
• Sample ports—septum-style and needle-free ports.
• Clamps—sliders, pinch, and crimp bands.

Thermo Scientific Aegis5-14 Single-Use BioProcess Container (BPC), 200 L (Thermo Scientific™)

The 200 L Thermo Scientific™ BPC is composed of Thermo Scientific Aegis5-14 film, a single-web, five-layer, animal-origin free film. This BPC includes 3 ports (all MPX inserts).

Features:

• All BPCs are constructed in an ISO 7 (Class 10,000) cleanroom, which complies with cGMP standards.
• Manufactured with industry-leading Aegis5-14 film
• C-flex tubing that can be used with tubing welder and various connection options
• Flexible and economic solution to update or increase your bioreactor capacity
• Suitable for both suspension and adherent cultures
• Configurable to meet your process needs, including options for single-use sensing (DO, pH, and pressure)

Customize standard BPC systems for optimized single-use technology

Choose from a large component library – with over 2,000 unique components that include:

• Fittings—straight, reducing, elbow, T-style, X-style, and cross-style.
• Connectors—quick connectors/disconnectors, aseptic connectors and disconnectors, steam-to and steam-through connectors.
• Filters—used for bioburden reduction; sterilization grade filters and gas filters.
• Tubing—thermoplastic elastomers, platinum-cured silicone.
• Sample ports—septum-style and needle-free ports.
• Clamps—sliders, pinch, and crimp bands.

Thermo Scientific Aegis5-14 Single-Use BioProcess Container (BPC), with 3 ports, 2D (Thermo Scientific™)

The 50 L Thermo Scientific™ Labtainer BPC is composed of Thermo Scientific Aegis5-14 film, a single-web, five-layer, animal-origin free film. This BPC includes 3 probe ports (MPC body + MPC insert + Luer lock connection).

Features:

• All BPCs are constructed in an ISO 7 (Class 10,000) cleanroom, which complies with cGMP standards.
• Manufactured with industry-leading Aegis5-14 film
• C-flex tubing that can be used with tubing welder and various connection options
• Flexible and economic solution to update or increase your bioreactor capacity
• Suitable for both suspension and adherent cultures
• Configurable to meet your process needs, including options for single-use sensing (DO, pH, and pressure)

Customize standard BPC systems for optimized single-use technology

Choose from a large component library – with over 2,000 unique components that include:

• Fittings—straight, reducing, elbow, T-style, X-style, and cross-style.
• Connectors—quick connectors/disconnectors, aseptic connectors and disconnectors, steam-to and steam-through connectors.
• Filters—used for bioburden reduction; sterilization grade filters and gas filters.
• Tubing—thermoplastic elastomers, platinum-cured silicone.
• Sample ports—septum-style and needle-free ports.
• Clamps—sliders, pinch, and crimp bands.

BioProcess Container (BPC), 500L, for Single-Use Mixing Systems (S.U.M.s), for use with powder-to-liquid mixing applications (Thermo Scientific™)

The 500L, powder-to-liquid, Thermo Scientific™ BioProcess Container (BPC) for Single-Use Mixing Systems (S.U.M.) is a flexible container system with specially designed ports and connectors for compatibility with S.U.M.™ systems.

BPC Components include:
• Powder Addition Port for addition of powder intended for connection to Powdertainer
• Ports for addition of media and other liquids
• Seal/Bearing Assembly that is linked to seal/bearing assembly by C-Flex™ tubing which forms the contact material for the shaft
• Impeller of molded polyethylene that is linked to seal/bearing assembly by C-Flex tubing which forms the contact material for the shaft
• Drain Port used when draining the S.U.M.

2D Labtainer™ BioProcess Container (BPC), ASI™ 28 film, 1 port, Luer Lock body connector (Thermo Scientific™)

The 1 L Thermo Scientific™ Labtainer™ BioProcess Container (BPC) 2D system is composed of Thermo Scientific™ ASI™ 28 film, a 4-layer, 12.5 mL, animal origin–free ethyl vinyl acetate film and includes 1 port (1 luer body + cap).

Features of the system include:
• Helps to eliminate post-use cleaning steps required with reusable containers, and to reduce cross-contamination risks
• All Labtainers constructed in an ISO 7 cleanroom environment under cGMP conditions

Applications include:
• Harvesting from, feeding into, and collecting samples from bioreactors and fermenters
• Preparing and storing buffer, culture media, and process liquid
• Collecting chromatography feed and fraction
• Harvesting, storing, and transporting bulk drug product and drug precursors

Customize standard BPC systems for optimized single-use technology
Choose from the industry’s largest component library, with over 2,000 unique components that include:
• Fittings—straight, reducing, elbow, T-style, X-style, and cross-style
• Connectors—quick connectors/disconnectors, aseptic connectors and disconnectors, and steam-to and steam-through connectors
• Filters (used for bioburden reduction)—sterilization grade filters and vent filters
• Tubing—thermoplastic elastomers and platinum-cured silicone
• Sample ports—septum-style and needle-free ports
• Clamps—sliders, pinch, and crimp bands

Thermo Scientific™ RockIt rocking bioreactor BioProcess Container (BPC) (Thermo Scientific™)

The 50L Thermo Scientific™ RockIt rocking bioreactor BioProcess Container (BPC) is composed of Aegis5-14 single web, multi-layer plastic film, with dimensions optimized for General Electric Health Care (GEHC) Wave 20/50 and Wave 25 equipment. Standard Thermo Scientific RockIt BPCs are 2-panel / pillow-style BPCs that feature inoculation and harvest lines, inlet and outlet gas filters, as well as a sample port and an extra port.

• Supplied gamma-irradiated and ready-to-use, Thermo Scientific RockIt BPCs are constructed in an ISO 7 cleanroom under cGMP conditions.

• Eliminates post-use cleaning steps required with re-useable containers and reduce cross-contamination risks.

Applications of the Thermo Scientific RockIt BPCs:

• Removes the need for tank cleaning and helps reduce cycle times.

• Cultivation of mammalian cells at the bench-top scale.

BioProcess Container (BPC),1000L, for Single-Use Mixing Systems (S.U.M.s), for use with powder-to-liquid mixing applications (Thermo Scientific™)

The 1000L, powder-to-liquid, Thermo Scientific™ BioProcess Container (BPC) for Single-Use Mixing Systems (S.U.M.) is a flexible container system with specially designed ports and connectors for compatibility with S.U.M.™ systems.

BPC Components include:
• Powder Addition Port for addition of powder intended for connection to Powdertainer
• Ports for addition of media and other liquids
• Seal/Bearing Assembly that is linked to seal/bearing assembly by C-Flex™ tubing which forms the contact material for the shaft
• Impeller of molded polyethylene that is linked to seal/bearing assembly by C-Flex tubing which forms the contact material for the shaft
• Drain Port used when draining the S.U.M.

Labtainer™ BioProcess Container (BPC), 500mL with 2 Ports, Luer Lock, 2D BPC (Thermo Scientific™)

The 500 mL Thermo Scientific™ Labtainer™ BPC, 2D system is composed of CX5-14 single-web, multi-layer film, and includes 2 edge ports (male and female luer lock connections).

Features:
• Use this system to eliminate post-use cleaning steps required with re-useable containers, and to reduce cross-contamination risks.
• All Labtainers are constructed in an ISO 7 cleanroom under cGMP conditions.

Applications of the Thermo Scientific Labtainer BPC include:
• Harvest from, feed into, and collect samples from bioreactors and fermentors.
• Buffer, culture media, and process liquid preparation and storage.
• Chromatography feed and fraction collection.
• Harvest, storage and transport of bulk drug product and bulk drug precursors.

Customize standard BPC systems for optimized single-use technology
Choose from the industry’s largest component library – with over 20,000 unique components that include:
Fittings—straight, reducing, elbow, T-style, X-style, and cross-style.
Connectors—quick connectors/disconnectors, aseptic connectors and disconnectors, steam-to and steam-through connectors.
Filters—used for bioburden reduction; sterilization grade filters and vent filters.
Tubing—thermoplastic elastomers, platinum-cured silicone.
Sample ports—septum-style and needle-free ports.
Clamps—sliders, pinch, and crimp bands.

BioProcess Container (BPC), 200L, for Single-Use Mixing Systems (S.U.M.s), for use with liquid-to-liquid mixing applications (Thermo Scientific™)

The 200L, liquid-to-liquid, Thermo Scientific™ BioProcess Container (BPC) for Single-Use Mixing Systems (S.U.M.) is a flexible container system with specially designed ports and connectors for compatibility with S.U.M.™ systems.

BPC Components include:
• Powder Addition Port for addition of powder intended for connection to Powdertainer
• Ports for addition of media and other liquids
• Seal/Bearing Assembly that is linked to seal/bearing assembly by C-Flex™ tubing which forms the contact material for the shaft
• Impeller of molded polyethylene that is linked to seal/bearing assembly by C-Flex tubing which forms the contact material for the shaft
• Drain Port used when draining the S.U.M.

imPULSE™ Single-Use Mixer Air Inflate and Purge Transfer Assembly (Thermo Scientific™)

The Thermo Scientific™ Inflation Transfer Assembly, 1.27 cm (.5 in.), consists of silicone tubing with MPX inserts with caps and a sanitary barb with a gasket, end cap, and push/pull clip. This transfer assembly is compatible with the Thermo Scientific™ imPULSE™ Single-Use BioProcess Container (BPC), ranging from 30 L to 750 L.

Features
• Minimizes bioburden due to construction under sterile cGMP conditions

Tubing specifications:
• Tubing: Silicone, 365.8 cm (144 in.), ID x OD: 1.27 x 1.91 cm (0.5 x 0.75 in.)
• T1: 3.8 cm (1.5 in.) sanitary x 1.27 cm (0.5 in.) barb with gasket, end cap, push/pull clip
• T2: MPX insert + cap

2D Labtainer™ BioProcess Container (BPC), ASI™ 28 film, 1 port, Luer Lock connector (Thermo Scientific™)

The 5 L Thermo Scientific™ Labtainer™ BioProcess Container (BPC) 2D system is composed of Thermo Scientific™ ASI™ 28 film, a 4-layer, 12.5 mL, animal origin–free ethyl vinyl acetate film and includes 1 port (1 luer body + cap).

Features of the system include:
• Helps to eliminate post-use cleaning steps required with reusable containers, and to reduce cross-contamination risks
• All Labtainers constructed in an ISO 7 cleanroom environment under cGMP conditions

Applications include:
• Harvesting from, feeding into, and collecting samples from bioreactors and fermenters
• Preparing and storing buffer, culture media, and process liquid
• Collecting chromatography feed and fraction
• Harvesting, storing, and transporting bulk drug product and drug precursors

Customize standard BPC systems for optimized single-use technology
Choose from the industry’s largest component library, with over 2,000 unique components that include:
• Fittings—straight, reducing, elbow, T-style, X-style, and cross-style
• Connectors—quick connectors/disconnectors, aseptic connectors and disconnectors, and steam-to and steam-through connectors
• Filters (used for bioburden reduction)—sterilization grade filters and vent filters
• Tubing—thermoplastic elastomers and platinum-cured silicone
• Sample ports—septum-style and needle-free ports
• Clamps—sliders, pinch, and crimp bands

Labtainer™ BioProcess Container (BPC), 1L with 2 Ports, Luer Lock, No Tubing, 2D BPC (Thermo Scientific™)

The 1 L Thermo Scientific™ Labtainer™ BPC, 2D system is composed of CX5-14 single-web, multi-layer film, and includes 2 edge ports (male and female luer lock connections).

Features:
• Use this system to eliminate post-use cleaning steps required with re-useable containers, and to reduce cross-contamination risks.
• All Labtainers are constructed in an ISO 7 cleanroom under cGMP conditions.

Applications of the Thermo Scientific Labtainer BPC include:
• Harvest from, feed into, and collect samples from bioreactors and fermentors.
• Buffer, culture media, and process liquid preparation and storage.
• Chromatography feed and fraction collection.
• Harvest, storage and transport of bulk drug product and bulk drug precursors.

Customize standard BPC systems for optimized single-use technology
Choose from the industry’s largest component library – with over 20,000 unique components that include:
Fittings—straight, reducing, elbow, T-style, X-style, and cross-style.
Connectors—quick connectors/disconnectors, aseptic connectors and disconnectors, steam-to and steam-through connectors.
Filters—used for bioburden reduction; sterilization grade filters and vent filters.
Tubing—thermoplastic elastomers, platinum-cured silicone.
Sample ports—septum-style and needle-free ports.
Clamps—sliders, pinch, and crimp bands.

2D Labtainer™ BioProcess Container (BPC), ASI™ 28 film, 3 ports, MPC insert and body connectors with clamps, injection site (Thermo Scientific™)

The 5 L Thermo Scientific™ Labtainer™ BioProcess Container (BPC) 2D system is composed of Thermo Scientific™ ASI™ 28 film, a 4-layer, 12.5 mL, animal origin–free ethyl vinyl acetate film and includes 3 ports (1 MPC insert + cap and pinch clamp, 1 MPC body + cap and pinch clamp, 1 injection site).

Features of the system include:
• Helps to eliminate post-use cleaning steps required with reusable containers, and to reduce cross-contamination risks
• All Labtainers constructed in an ISO 7 cleanroom environment under cGMP conditions

Applications include:
• Harvesting from, feeding into, and collecting samples from bioreactors and fermenters
• Preparing and storing buffer, culture media, and process liquid
• Collecting chromatography feed and fraction
• Harvesting, storing, and transporting bulk drug product and drug precursors

Customize standard BPC systems for optimized single-use technology
Choose from the industry’s largest component library, with over 2,000 unique components that include:
• Fittings—straight, reducing, elbow, T-style, X-style, and cross-style
• Connectors—quick connectors/disconnectors, aseptic connectors and disconnectors, and steam-to and steam-through connectors
• Filters (used for bioburden reduction)—sterilization grade filters and vent filters
• Tubing—thermoplastic elastomers and platinum-cured silicone
• Sample ports—septum-style and needle-free ports
• Clamps—sliders, pinch, and crimp bands

BioProcess Container (BPC), 500L, for Single-Use Mixing Systems (S.U.M.s), for use with liquid-to-liquid mixing applications (Thermo Scientific™)

The 500L, liquid-to-liquid, Thermo Scientific™ BioProcess Container (BPC) for Single-Use Mixing Systems (S.U.M.) is a flexible container system with specially designed ports and connectors for compatibility with S.U.M.™ systems.

BPC Components include:
• Powder Addition Port for addition of powder intended for connection to Powdertainer
• Ports for addition of media and other liquids
• Seal/Bearing Assembly that is linked to seal/bearing assembly by C-Flex™ tubing which forms the contact material for the shaft
• Impeller of molded polyethylene that is linked to seal/bearing assembly by C-Flex tubing which forms the contact material for the shaft
• Drain Port used when draining the S.U.M.

BioProcess Containers (BPC), 500L, for HyPerforma™ Single-Use Mixer and docking tank, liquid-to-liquid w/probe ports (Thermo Scientific™)

The 500L Thermo Scientific™ Bioprocess Container (BPC) with probe ports is for use with the Thermo Scientific™ HyPerforma™ Single-Use Mixer and docking tank for liquid-to-liquid mixing.

Single Use Mixer (S.U.M.) BPC options include:
• Open top liner for media/buffer hydration
• Closed BPC with powder port for contained media/buffer hydration
• Closed BPC with powder port and monitoring probe capability
• Closed BPC for liquid-liquid mixing of critical sterile solutions such as pooling of fractions or processing of intermediate solutions
• Closed BPC for liquid-liquid mixing with monitoring probe capability