As veterans and innovators in real-time PCR (qPCR), we have a wealth of information, both technical and educational, to empower your qPCR research. We’ve featured some of the most frequented resources for both master mixes and general qPCR below.
Different qPCR applications call for different chemistries and performance characteristics. Explore the portfolios below to compare SYBR Green, TaqMan, and TaqPath master mixes and find the right solution for your workflow.
Yes. Applied Biosystems master mixes are compatible with a broad range of qPCR instruments from multiple manufacturers. Performance is influenced by factors such as assay design, instrument configuration, and workflow optimization. Refer to the product documentation for instrument-specific recommendations.
Applied Biosystems master mixes are compatible with a broad range of qPCR instruments from multiple manufacturers. Compatibility may vary depending on instrument settings, passive reference dye requirements, assay design, and workflow conditions. Refer to product documentation and instrument guidance for platform-specific recommendations.
Applied Biosystems master mixes can be used on a broad range of qPCR instruments from multiple manufacturers. The appropriate master mix depends primarily on your application, such as gene expression analysis, microbial detection, multiplex qPCR, or fast-cycling workflows, rather than the instrument manufacturer. Review the master mix specifications and application recommendations to identify the best option for your workflow.
Possibly. Some instruments may require minor optimization of denaturation, annealing, or extension temperatures and times. We also recommend confirming the appropriate reaction volume for your instrument, as optimal reaction volumes can vary between platforms.
Many assays can be transferred with minimal changes; however, some workflows may benefit from optimization when changing reagents or instrument platforms. Factors such as cycling conditions, reaction volume, primer and probe concentrations, and instrument settings can influence assay performance.
Yes. Many non-Applied Biosystems qPCR instruments can be used with master mixes that contain ROX dye. Whether ROX dye is used as a passive reference depends on the instrument's optical design and software settings. Refer to your instrument documentation to determine the appropriate passive reference dye settings and calibration requirements.
The appropriate ROX dye setting depends on your instrument and software configuration. Refer to your instrument user guide for recommendations on passive reference dye selection and setup.
Data normalization depends on the passive reference dye requirements of your instrument and analysis software. If your instrument uses ROX dye as a passive reference, select the appropriate ROX dye setting during experiment setup and data analysis. Refer to your instrument documentation for guidance.
Yes. Applied Biosystems master mixes can be used for multiplex qPCR workflows on both Applied Biosystems and non-Applied Biosystems instruments. Successful multiplexing depends on factors such as fluorophore compatibility, optical filter configuration, passive reference dye selection, and assay optimization. Verify that the fluorophores used in your assay are compatible with your instrument's detection channels.
Fast cycling may be possible if the selected master mix supports fast cycling conditions and the instrument is capable of running fast protocols. Refer to the master mix user guide and instrument documentation for compatibility and recommended cycling conditions.
No. Applied Biosystems master mixes do not require additional additives or enhancers for use on non-Applied Biosystems qPCR instruments. Follow the recommended protocol provided with the master mix and instrument.
For Research Use Only. Not for use in diagnostic procedures.