For standard pipetting use Forward Technique:
Recommended for aqueous solutions, such as buffers, diluted acids, or alkalis, this technique is commonly used when pipetting and mixing a sample or reagent into another liquid.

For solutions with high viscosity or tendency to foam use Reverse Technique:
This technique is commonly used with air displacement pipettes, and is recommended for precisely pipetting small volumes. Reverse pipetting avoids the risk of sample splash, foaming, or bubble formation.

Isn’t all labware the same? No, and let us explain why

There are a lot of plastic labware choices, but the quality of your work often depends on using quality plastic labware. Even though they may look alike, not all labware products are created equal. Lower-cost alternatives come with a nice price, but remember that old saying, “You get what you pay for.”

Regulatory Standards:
High-quality plastic labware must meet accepted ASTM and ISO accuracy standards and be made from laboratory-grade plastic materials that won’t leach impurities into your reagents and samples. Containers should provide guaranteed leak-proof performance to keep you safe from exposure and your work safely contained. 

5 Quick Tips | Select the right tip for your application - Ask yourself these questions:

   What type of liquid are you pipetting?
Aqueous solutions work well with standard pipette tips. For viscous and “foamy” solutions or small volumes, consider low-retention tips for maximum sample delivery. Filter/Barrier tips are recommended for solutions containing nucleotides, radioactive compounds, and where contamination control is critical.
   What are you pipetting to/from?
Standard tips are great for microplates and micro centrifuge tubes. For taller vessels like tubes, flasks and bottles, extended length tips keep the pipette shaft from touching the inside walls allowing access to the bottom while preventing carryover contamination.
   How concerned are you about contamination?
Filter tips help prevent contamination by blocking aerosols and preventing liquid from accidentally splashing the inside of the pipette. Filter or barrier tips are recommended for sensitive assays like PCR, genetic studies, forensics, and radioisotope sampling.
   What pipette are you using? 
Tips that are designed and manufactured for your specific pipette provide an optimal fit, but high quality universal tips - such as ART pipette tips, are also a good option.
   Is this an extremely sensitive application?
Individually wrapped sterile tips are ideal for sensitive applications requiring aseptic conditions.

 View the quick reference chart 

Get a Nalgene Chemical Resistance Poster for your lab

Top 10 Nalgene

There are no toxic additives in our Nalgene plastics that can leach out into your lab solutions and ruin your experiments?

We use laboratory-grade plastic resin materials to make our products. Customers trust Nalgene products to look and perform perfectly every time and rely on us to provide them with products that are good enough for their important lab work.

Here are a few Nalgene "must-haves" for your bench.

  Watch the video

Ergonomic advice for the bench

Special Offers

Save $200 or $225 when you purchase Finnpipette Novus pipettes with one case of Finntips and one case of Abgene storage plates.

Shop Now

Save 20% on selected Nalgene Labware

Shop Now

Recommendations for pipetting different compounds



Pipette Tip 

Pipetting Technique 

 Aqueous Solution Air displacement Standard Forward
Example:  Buffers, Diluted Salt Solutions
Viscous Solutions

Air displacement

Positive displacement

Standard or wide orifice, Low retention

Positive displacement
Example:  Protein and nucleic solutions, glycerol, Tween 20/40/60/80
Volatile Compounds

Air displacement

Positive displacement

Filter barrier

Positive displacement
Example: Methanol, hexane
Body Fluids Air displacement Standard or wide orifice tip Heterogeneous*
Example: Whole blood, serum
Nucleotide Solutions

Air displacement

Positive displacement

Filter barrier or wide orifice

Positive displacement
Example: Genomic DNA, PCR products
Radioactive Compounds

Air displacement

Positive displacement

Filter barrier

Positive displacement
Example: Carbonate, H-thymidine
Acids/Alkalis Air displacement Filter barrier Forward
Example: H 2, SO 4, HCl, NaOH
Toxic Samples

Air displacement

Positive displacement

Filter barrier

Positive displacement
Forward or reverse
Example: NA


*Air displacement

Positive displacement

Air displacement

Positive displacement

*With blood or serum reverse technique is another option. During the aspiration and dispensing, use very slow plunger movements. When aspirating, hold the tips in the liquid for a few seconds, after the plunger is in the upper position. Also, when dispensing, move plunger slowly and wait a few seconds when plunger is in the down position.

 Proven Steps to Improve your Pipetting Accuracy

Aspirate and fully expel an amount of the liquid at least three times before aspirating for delivery. Failure to pre-wet the tip increases evaporation within the tip air space, which can cause significantly lower delivery volumes. Pre-wetting increases the humidity within the tip, thus reducing evaporation.

Allow liquids and equipment to equilibrate to ambient temperature prior to pipetting. The volume of liquid delivered by air displacement pipettes varies with relative humidity and vapor pressure of the liquid – both of which are temperature-dependent. Working at a constant temperature minimizes variation of pipetted volume.

Before dispensing, carefully remove droplets from the outside of the tip by touching off the side of the reservoir, being sure to stay clear of the tip opening to avoid wicking liquid out of the tip. After dispensing, and before releasing the plunger, deliver any residual liquid remaining in the tip by touching the tip to the side of the container. Surface tension will help draw the remaining liquid out of the tip.

Depress the plunger to the first stop, immerse the tip into the liquid, and aspirate by releasing the plunger. Remove the pipette from the liquid and depress the plunger to the second stop to dispense the entire contents. Standard (or forward) mode pipetting yields better accuracy and precision than reverse mode for all but viscous or volatile liquids. Reverse mode often results in over-delivery. Hence, it’s recommended to evaluate the effect of possible over-delivery in the experiment and make adjustments if needed.

In this experiment 200µL of  viscous liquid (glycerol) was pipetted 10 times by using both forward and reverse pipetting techniques. The pipette used was adjusted for glycerol using forward pipetting. The chart describes the accuracy and precision obtained with both techniques.

Using the reverse method a smaller deviation between doses was observed and therefore reduced imprecision.

The reverse method gave bigger doses as the liquid column in the tip is taller and therefore the liquid amount above the dose presses a larger dose out.

After aspirating, and before removing the tip from the liquid, pause for one second. Make this pause as consistent as possible. Liquid continues to flow into the tip for a short time after the plunger stops. At the same time, evaporation within the tip is occurring. Pausing consistently balances these two effects and ensures correct aspiration.

When aspirating liquid, hold the pipette vertically and pull the pipette straight out from the center of the reservoir. This technique is especially important when pipetting small volumnes (less than 50µL). Holding the pipette at an angle as it is removed from the liquid alters the aspirated volume.

Hold the pipette loosely and utilize the finger rest. Remember to return the pipette to the pipette stand between deliveries. Avoid handling pipette tips or reservoirs with bare hands. Body heat transferred during handling disturbs temperature equilibrium, which leads to variations in delivered volume.

Before aspirating, immerse the tip adequately below the meniscus. Too little immersion, particularly with large volume pipettes, can lead to aspiration of air. Too much immersion can cause liquid to cling to the outside of the tip. Contacting the container bottom with the tip may restrict aspiration.

Use high-quality tips intended for use with the pipette. System tips are designed to work with their matching pipettes. Mismatched tips and pipettes can result in inaccuracy, imprecision, or both. Quality system tips provide an airtight seal, are made of superior materials, and are free of molding defects. They also ensure dependable liquid delivery.

Depress the plunger smoothly until coming to rest with a light and consistent force at the first stop. Immerse the tip, and  then release the plunger at a constant rate. Repeatable actions produce repeatable results.