Thermo Scientific™ Ramsey™ Oretronic IV Tramp Metal Detector

Catalog number: ORETRONICIV6

Thermo Scientific™ Ramsey™ Oretronic IV Tramp Metal Detector

Catalog number: ORETRONICIV6
The Thermo Scientific™ Ramsey™ Oretronic IV Tramp Metal Detector reliably protects expensive process equipment such as crushers and conveyors from damage by all types of metallic scrap (tramp metal). Designed for easy installation on belt conveyors moving bulk materials it helps to minimize lost production time and expensive repairs/replacement. The Oretronic IV is insensitive to materials with high magnetic permeability and electrical conductivity, making it suitable for applications where conventional metal detectors produce an unacceptable false alarm rate, and can even detect tramp metal buried in wet conductive materials. Easy to set-up, operate, and maintain it simplifies the implementation of effective damage prevention strategies that protect the bottom line. We will help you to choose between the 4 control and 6 control models, tailoring options to best suit your specific application.
 
Catalog Number
ORETRONICIV6
Unit Size
Each
Description
Oretronic IV Tramp Metal Detector, 6 Control
Price (USD)
Full specifications
Belt Speed1.5 m/min to 550 m/min (5 ft/min to 1800 ft/min)
Certifications/ComplianceISO-9001 Certified
DescriptionOretronic IV Tramp Metal Detector, 6 Control
Enclosure Size687 x 524 x 230 mm (27 x 20.6 x 9.1 in.)
ElectronicsSwitch seletable 115/230 VAC, +10%, -15%
50/60 Hz
Single phase, 30 VA, 0.25A
Enclosure MaterialPainted mild steel conforms to NEMA-4, IP66 dust and water tight
Input/Output

Input Power Requirments: 98-253 (fiberglass enclosure) or 115-230 VAC (steel enclosure) VAC, +10%, -15%
50/60 Hz
Single phase, 0.9A (fiberglass enclosure) or 2.8A (steel enclosure)

Output Relay Rating: User supplied 5A max, 250 VAC or 30 VDC
NO and NC Contacts:  Alarm Indicator, Alarm, Marker Output
NC Contacts:  Bypass, Power OK

Operating Temperature-40°C to +58°C (-40°F to +136°F)
Overall Humidity10% up to 95%, non-condensing
Storage Temperature-30°C to +70°C (-22°F to +158°F)
TypeMetal detector
Communication PortsOptional RS-485
Display TypeLCD with Backlight
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Oretronic IV Tramp Metal Detector, 4 Control
Price (USD)
Full specifications
Belt Speed1.5 m/min to 550 m/min (5 ft/min to 1800 ft/min)
Certifications/ComplianceISO-9001 Certified
DescriptionOretronic IV Tramp Metal Detector, 4 Control
Enclosure Size432 x 360 x 184 mm (17 x 14.2 x 7.2 in.)
ElectronicsSwitch seletable 115/230 VAC, +10%, -15%
50/60 Hz
Single phase, 30 VA, 0.25A
Enclosure MaterialReinforced fiberglass conforms to NEMA-4X, IP66 dust and water tight
Input/Output

Input Power Requirments: 98-253 (fiberglass enclosure) or 115-230 VAC (steel enclosure) VAC, +10%, -15%
50/60 Hz
Single phase, 0.9A (fiberglass enclosure) or 2.8A (steel enclosure)

Output Relay Rating: User supplied 5A max, 250 VAC or 30 VDC
NO and NC Contacts:  Alarm Indicator, Alarm, Marker Output
NC Contacts:  Bypass, Power OK

Operating Temperature-40°C to +58°C (-40°F to +136°F)
Overall Humidity10% up to 95%, non-condensing
Storage Temperature-30°C to +70°C (-22°F to +158°F)
TypeMetal detector
Communication PortsOptional RS-485 serial communication
Display TypeLCD
Unit SizeEach
Showing 2 of 2
Catalog NumberSpecificationsUnit SizeDescriptionPrice (USD)
ORETRONICIV6Full specifications
EachOretronic IV Tramp Metal Detector, 6 ControlRequest A Quote
Belt Speed1.5 m/min to 550 m/min (5 ft/min to 1800 ft/min)
Certifications/ComplianceISO-9001 Certified
DescriptionOretronic IV Tramp Metal Detector, 6 Control
Enclosure Size687 x 524 x 230 mm (27 x 20.6 x 9.1 in.)
ElectronicsSwitch seletable 115/230 VAC, +10%, -15%
50/60 Hz
Single phase, 30 VA, 0.25A
Enclosure MaterialPainted mild steel conforms to NEMA-4, IP66 dust and water tight
Input/Output

Input Power Requirments: 98-253 (fiberglass enclosure) or 115-230 VAC (steel enclosure) VAC, +10%, -15%
50/60 Hz
Single phase, 0.9A (fiberglass enclosure) or 2.8A (steel enclosure)

Output Relay Rating: User supplied 5A max, 250 VAC or 30 VDC
NO and NC Contacts:  Alarm Indicator, Alarm, Marker Output
NC Contacts:  Bypass, Power OK

Operating Temperature-40°C to +58°C (-40°F to +136°F)
Overall Humidity10% up to 95%, non-condensing
Storage Temperature-30°C to +70°C (-22°F to +158°F)
TypeMetal detector
Communication PortsOptional RS-485
Display TypeLCD with Backlight
Unit SizeEach
ORETRONICIV4Full specifications
EachOretronic IV Tramp Metal Detector, 4 ControlRequest A Quote
Belt Speed1.5 m/min to 550 m/min (5 ft/min to 1800 ft/min)
Certifications/ComplianceISO-9001 Certified
DescriptionOretronic IV Tramp Metal Detector, 4 Control
Enclosure Size432 x 360 x 184 mm (17 x 14.2 x 7.2 in.)
ElectronicsSwitch seletable 115/230 VAC, +10%, -15%
50/60 Hz
Single phase, 30 VA, 0.25A
Enclosure MaterialReinforced fiberglass conforms to NEMA-4X, IP66 dust and water tight
Input/Output

Input Power Requirments: 98-253 (fiberglass enclosure) or 115-230 VAC (steel enclosure) VAC, +10%, -15%
50/60 Hz
Single phase, 0.9A (fiberglass enclosure) or 2.8A (steel enclosure)

Output Relay Rating: User supplied 5A max, 250 VAC or 30 VDC
NO and NC Contacts:  Alarm Indicator, Alarm, Marker Output
NC Contacts:  Bypass, Power OK

Operating Temperature-40°C to +58°C (-40°F to +136°F)
Overall Humidity10% up to 95%, non-condensing
Storage Temperature-30°C to +70°C (-22°F to +158°F)
TypeMetal detector
Communication PortsOptional RS-485 serial communication
Display TypeLCD
Unit SizeEach
Showing 2 of 2

The Ramsey Oretronic IV Tramp Metal Detector provides the economic and reliable protection against tramp metal that proactive operators and owners consider essential for cost-effective and productive operation. Key features include:

  • Microprocessor-based, advanced electronic control unit, for automated set-up and calibration.
  • User-friendly operator interface, for easy-to-read viewing and simplified set-up/maintenance.
  • Designed for simple installation with no belt cutting or special tools/instruments required.
  • Variable operator-set frequency detection, for the elimination of interference from other electrical equipment.
  • Quick balance feature, for fast and easy electronic coil balancing at the push of a key.
  • PVC coils, mounted on a fiberglass support structure, for improved sensitivity, impact and moisture resistance.
  • Offset swing arm, for coil protection and reduced risk of breakage.
  • Single, under-the-belt coil assembly (optional), for the elimination of damage from high burden depths and interference from overhead metal objects.
  • Distance indicator (optional), displaying distance from coil to tramp metal for the rapid location of detected tramp metal.
  • Heater (optional), for effective control at low temperatures (115 or 230V).
  • Plug-in RS485 communications board (optional), for serial communications, where required.

Additional Features for the Oretronic IV 4 Control:

  • IP66 fiberglass enclosure for long-term, effective system protection.
  • External reset button for easy restart

Additional Features for the Oretronic IV 6 Control:

  • IP66 painted steel enclosure, for enhanced durability in harsh operating environments.
  • Higher power coil excitation for higher sensitivity