Kits de ensayo de microARN Qubit™
Kits de ensayo de microARN Qubit™
Invitrogen™

Kits de ensayo de microARN Qubit™

El kit de ensayo de microARN Qubit permite una cuantificación fácil y precisa del microARN (miARN) mediante el fluorímetro Qubit,Más información
Have Questions?
Cambiar vistabuttonViewtableView
Número de catálogoN.º de reacciones
Q32880100 reacciones
Q32881500 reacciones
Número de catálogo Q32880
Precio (CLP)
133.664
Each
Añadir al carro de la compra
N.º de reacciones:
100 reacciones
Precio (CLP)
133.664
Each
Añadir al carro de la compra
El kit de ensayo de microARN Qubit permite una cuantificación fácil y precisa del microARN (miARN) mediante el fluorímetro Qubit, incluso en presencia de contaminantes comunes como sales, nucleótidos libres, disolventes, detergentes y proteínas. El ensayo es altamente selectivo para miARN sobre ARNr o ARNm largo (> 1000 bp). Aunque el reactivo no es exclusivamente selectivo para el miARN, hemos podido cuantificar de forma reproducible el miARN en muestras puras a niveles tan bajos como 0,5 ng en el tubo de ensayo siguiendo el protocolo suministrado a continuación, incluso en presencia de ARNm.

Características del ensayo de microARN Qubit:
• Detecta con precisión tan solo 0,5 ng de miARN en el tubo de ensayo
• Intervalo dinámico del núcleo de 5 a 500 ng/ml
• Resultados precisos para concentraciones de muestras de 50 ng/ml a 100 µg/ml

El kit de ensayo de microARN Qubit proporciona reactivos de ensayo concentrados, tampón de dilución y patrones de miARN prediluidos. Basta con diluir el reactivo mediante el tampón proporcionado, añadir la muestra (cualquier volumen entre 1 µl y 20 µl es aceptable) y leer la concentración mediante el fluorímetro Qubit. Dado que el ensayo tolera de 1 a 20 µl de muestra en un volumen de ensayo de 200 µl, se pueden obtener resultados precisos para las concentraciones iniciales de la muestra a partir de 50 ng/ml a 100 µg/ml.

¿Qué producto elegir para la cuantificación de microARN?

• Para 1–20 muestras: utilice este kit de ensayo de microARN Qubit con el fluorímetro Qubit
• Para 20–2000 muestras: utilice el kit de ensayo de microARN Quant-iT con lector de microplacas
• Para > 2000 muestras: utilice el reactivo de microARN Quant-iT con lector de microplacas

Notas:
1. El archivo de ensayo de microARN Qubit se incluye en todos los fluorímetros Qubit 3 y Qubit 4, pero puede requerir la instalación en el fluorímetro Qubit 2.0. La carga de nuevos ensayos en el fluorímetro Qubit 2.0 requiere la versión 3.10 o posterior del firmware Qubit.
2. Se requieren tubos delgados de PCR de 500 µl, pero no se incluyen.
Para uso exclusivo en investigación. No apto para uso en procedimientos diagnósticos.
Especificaciones
Método de detecciónFluorescencia
Excitación/emisión498/518
Para utilizar con (aplicación)Cuantificación de microARN
Para utilizar con (equipo)Fluorímetro Qubit
N.º de reacciones100 reacciones
Línea de productosQubit
Tipo de productoKit de ensayo de microARN
Cantidad100 assays
Condiciones de envíoTemperatura ambiente
Unit SizeEach

Preguntas frecuentes

Can the Quant-iT RNA assay be used to quantitate RNA labeled with digoxigenin?

Yes, the tag does not interfere with the signal.

What are the excitation/emission wavelengths for dyes in the Qubit Assays?

The exact excitation/emission wavelength information is proprietary. Here are the approximate excitation/emission wavelengths:

- Qubit dsDNA HS Assay: ~500 nm/ ~530 nm
- Qubit dsDNA BR Assay: ~510 nm/ ~530 nm
- Qubit ssDNA Assay: ~490 nm/ ~520 nm
- Qubit RNA HS Assay: ~640 nm/ ~670 nm
- Qubit RNA BR Assay: ~640 nm/ ~670 nm
- Qubit microRNA Assay: ~500 nm/ ~520 nm
- Qubit Protein Assay: ~470 nm/ ~570 nm

Find additional tips, troubleshooting help, and resources within our Nucleic Acid Quantification Support Center.

How does the accuracy and sensitivity of the Qubit quantitation assays using the Qubit fluorometer compare to a microplate reader?

The accuracy and sensitivity of the Qubit quantitation assays are the same as that of a microplate reader. This was a requirement during product development. The detection limits for each Qubit kit can be found on the corresponding product manual, which can be found by searching our website by keyword or catalog number.

Find additional tips, troubleshooting help, and resources within our Nucleic Acid Quantification Support Center.

Can the Qubit kits give an indication of sample quality in nucleic acid samples?

No. The Qubit DNA and RNA kits only quantify the amount of either DNA or RNA in the sample. The Qubit fluorometer cannot take absorbance readings to provide a A260/A280 ratio or detect protein in nucleic acid samples. This can be done with the NanoDrop instrument. If your sample contains protein or other contaminants that can affect the assay, it should be further purified.

If your sample may contain both DNA and RNA, one may use either (or both) the DNA and RNA Qubit kits and compare with samples treated with either RNase or DNase to get an accurate determination of DNA or RNA, respectively.

Citations & References (7)

Citations & References
Abstract
Detection of microRNAs in DNA Extractions for Forensic Biological Source Identification.
Authors:Lewis CA, Layne TR, Seashols-Williams SJ
Journal:J Forensic Sci
PubMed ID:31107550
'Molecular-based approaches for biological source identification are of great interest in the forensic community because of a lack of sensitivity and specificity in current methods. MicroRNAs (miRNAs) have been considered due to their robust nature and tissue specificity; however, analysis requires a separate RNA extraction, requiring an additional step in ... More
Defining quantification methods and optimizing protocols for microarray hybridization of circulating microRNAs.
Authors:Garcia-Elias A, Alloza L, Puigdecanet E, Nonell L, Tajes M, Curado J, Enjuanes C, Díaz O, Bruguera J, Martí-Almor J, Comín-Colet J, Benito B
Journal:Sci Rep
PubMed ID:28798363
MicroRNAs (miRNAs) have emerged as promising biomarkers of disease. Their potential use in clinical practice requires standardized protocols with very low miRNA concentrations, particularly in plasma samples. Here we tested the most appropriate method for miRNA quantification and validated the performance of a hybridization platform using lower amounts of starting ... More
Circulating miRNAs, isomiRs and small RNA clusters in human plasma and breast milk.
Authors:Rubio M, Bustamante M, Hernandez-Ferrer C, Fernandez-Orth D, Pantano L, Sarria Y, Piqué-Borras M, Vellve K, Agramunt S, Carreras R, Estivill X, Gonzalez JR, Mayor A
Journal:PLoS One
PubMed ID:29505615
Circulating small RNAs, including miRNAs but also isomiRs and other RNA species, have the potential to be used as non-invasive biomarkers for communicable and non-communicable diseases. This study aims to characterize and compare small RNA profiles in human biofluids. For this purpose, RNA was extracted from plasma and breast milk ... More
Total RNA extraction from tissues for microRNA and target gene expression analysis: not all kits are created equal.
Authors:Brown RAM, Epis MR, Horsham JL, Kabir TD, Richardson KL, Leedman PJ
Journal:BMC Biotechnol
PubMed ID:29548320
microRNAs (miRNAs) are short non-coding RNAs that fine-tune gene expression. The aberrant expression of miRNAs is associated with many diseases and they have both therapeutic and biomarker potential. However, our understanding of their usefulness is dependent on the tools we have to study them. Previous studies have identified the need ... More
Differences in microRNA expression between melanoma and healthy adjacent skin.
Authors:Aksenenko M, Palkina N, Komina A, Tashireva L, Ruksha T
Journal:BMC Dermatol
PubMed ID:30611259
The tumor microenvironment is composed of cancer-associated fibroblasts, tumor-associated macrophages, endothelial cells, immune cells, signaling molecules and extracellular matrix structures, which closelycommunicate with the tumor via multiple mechanisms. MicroRNAs are paracrine regulators that provide a direct interaction between the microenvironment and cancer cells. In the presentstudy, we aimed to identify ... More