Plaques multipuits Nunc™ avec surface UpCell™
Plaques multipuits Nunc™ avec surface UpCell™
Thermo Scientific™

Plaques multipuits Nunc™ avec surface UpCell™

Permet la récolte non enzymatique des cellules adhérentes pour préserver la viabilité des cellules et les protéines de surface.
Have Questions?
Modifier l'affichagebuttonViewtableView
RéférenceNbre de puitsSurface de culture
174899241,9 cm2
174898481,1 cm2
174900123,5 cm2
17490169,6 cm2
Référence 174899
Prix (EUR)
217,00
Case of 6
Ajouter au panier
Nbre de puits:
24
Surface de culture:
1,9 cm2
Prix (EUR)
217,00
Case of 6
Ajouter au panier

Prenez en charge la récolte non enzymatique des cellules adhérentes pour la préservation de la viabilité des cellules et des protéines de surface grâce aux boîtes Thermo Scientific™ Nunc™ UpCell™. Transférez simplement la culture à température ambiante pour collecter les cellules en suspension ou sous forme de feuille cellulaire à l’aide d’une membrane de support.

Caractéristiques :
  • L’hydrophilicité de la surface UpCell change avec la température externe, ce qui permet aux cellules de se détacher
  • Il n’est pas nécessaire d’utiliser des enzymes de dissociation, cela garantit des protéines de surface intactes
  • Il n’y a pas besoin de grattage physique, cela entraîne une viabilité cellulaire élevée
  • Les membranes de support incluses dans les plaques à 6 puits permettent la récolte des tapis cellulaires
  • Code-barres personnalisé disponible
  • Durée de conservation : 3 ans à compter de la date de fabrication

Recommandées dans les cas suivants :

  • Passage de culture
  • Analyses des cellules simples ultérieures (par ex., cytométrie en flux)
  • Modélisation tissulaires en 3D pour la transplantation
  • Usage exclusivement réservé à la recherche
Garantie : 90 jours

 

Clause de non-responsabilité relative aux restrictions d’utilisation pour la recherche interne : toutes les restrictions qui s’appliquent à l’acheteur dans le cadre de l’utilisation du/des produit(s) à des fins de recherche interne uniquement ne s’appliquent pas au(x) produit(s) sur les pages Web associées à cette déclaration. Pour la recherche et à usage unique uniquement
Spécifications
CouleurTransparent
Description24 puits, UpCell
Nbre par carton6
Nb par paquet1
Traitement de surfaceTraitement par culture cellulaire
Type de puitsRectangular, Flat Bottom (F-well)
Surface de culture1,9 cm2
Nbre de puits24
StérilitéStérile
TypeMulti Dish
Volume (métrique) du puits1 ml (puits)
Volume (métrique) utile1 mL
Unit SizeCase of 6

Foire aux questions (FAQ)

Why does temperature reduction detach cells from the Nunc dishes with UpCell Surface?

The UpCell Surface is composed of a covalently bound polymer that changes from being slightly hydrophobic to being very hydrophilic when the temperature is reduced to less than 32 degrees C. This results in the binding of water to the surface, swelling of the surface, and finally the release of the cells.

In cultureware with UpCell surface, does the temperature-responsive polymer detach with the cells?

The temperature-responsive polymer is covalently bound to the polystyrene dish or plate and will not detach from the product under normal cell culture procedures and conditions. The products have successfully passed the USP biological reactivity class VI testing.

What is special about the "UpCell surface with grid"?

The “UpCell surface with grid” products have a 3 x 3 mm grid design over the entire culture surface. Cell attachment and growth is restricted to within these small squares, preventing cells from clumping, and enabling easier harvest of the cells as single cells or small cell clusters. Products with “UpCell surface with grid” are suitable for the preparation of cells for flow cytometry analysis but cannot be used for cell-sheet applications. We offer 60 mm and 100 mm dishes with “UpCell surface with grid” whereas the 35 mm dishes contain supportive membrane for harvesting of cell sheets.

Which cell types can I use with the UpCell surface?

You can use the UpCell Surface with many cell types, including fibroblasts, mesenchymal stem cells, myocytes, keratinocytes, macrophages, and different epithelium and tumor cells. If cells do not detach spontaneously from the UpCell surface by lowering of the temperature to below 32 degrees C, the cells can be detached by flushing the surface with medium or by tapping on the side of the dish or plate. Cells that produce a lot of extracellular matrix and attach very strongly to the UpCell surface may be difficult to detach by temperature reduction alone. For these cell types, the simultaneous use of diluted trypsin is recommended.

Can I coat the UpCell surface with biomolecules to enable cell attachment?

Coating of the UpCell surface with biomolecules, for example, collagen, fibronectin, poly-lysine and laminin, is possible and should be done if you experience difficulties in attaching your cells to the UpCell surface. The coating procedure should be performed at 37 degrees C.