RadEye™ SPRD-GN Spectroscopic Personal Radiation Detector

Référence: 4250813

RadEye™ SPRD-GN Spectroscopic Personal Radiation Detector

Référence: 4250813
Get RIID capability in the palm of your hand. The Thermo Scientific™ RadEye™ SPRD-GN Personal Radiation Detector is the first pager-sized PRD that significantly exceeds the original ANSI N42-48 2008 standards for neutron alarms. With outstanding neutron performance and reliable gamma IDs, the RadEye SPRD-GN Personal Radiation Detector may be the only radiation detection tool you will need.
 
Référence
4250813
Taille unitaire
-
Description
RadEye SPRD-GN Spectroscopic Personal Radiation Detector Kit, includes RadEye SPRD-GN, software, Holster, Lutetium test adapter, desktop holder, USB data cable, spare batteries, and rugged storage and carry case.
Spécifications complètes
DescriptionRadEye SPRD-GN Spectroscopic Personal Radiation Detector Kit, includes RadEye SPRD-GN, software, Holster, Lutetium test adapter, desktop holder, USB data cable, spare batteries, and rugged storage and carry case.
Unit Size-
Référence
Taille unitaire
Each
Description
RadEye SPRD-GN Personal Radiation Detector, includes software for configuring RadEye and Spectra download
Spécifications complètes
Sensibilité(cps per μSv/h (662 keV)) 110
Mesure du bruit de fondNBR (Natural Background Rejection): Advanced with 6 Energy Windows
Certifications/ConformitéIP65
DescriptionRadEye SPRD-GN Personal Radiation Detector, includes software for configuring RadEye and Spectra download
Gamme d’énergie60 keV to 3 MeV (+/- 30%)
Type de batterie2 AAA
Plages de mesureDose Rate Range: 1 μR/h to 25 mR/h (10 nSv/h to 250 μSv/h)
CommunicationsWireless communications BT4 optional
Temps de réponseTypical ID-time @ 1μSv/h (100μR/h) ∼5 min
Type de détecteurCLYC (Cs2LiYCl6)
Poids (métrique)0.175 kg (including batteries and rubber sleeve)
Types d’alarmeNeutron Alarm Response: ANSI N42.48-2008: Yes (< 2 s)
Distance de chute sur le béton1.5 m
Type de radiationGamma, Neutron
Autonomie de la batterie∼120 hr.
Poids (impériale)0.385 lb. (including batteries and rubber sleeve)
Unit SizeEach
Affichage de 2 sur 2
RéférenceSpécificationsTaille unitaireDescriptionPrix (EUR)
4250813Spécifications complètes
- RadEye SPRD-GN Spectroscopic Personal Radiation Detector Kit, includes RadEye SPRD-GN, software, Holster, Lutetium test adapter, desktop holder, USB data cable, spare batteries, and rugged storage and carry case.Demander un devis
DescriptionRadEye SPRD-GN Spectroscopic Personal Radiation Detector Kit, includes RadEye SPRD-GN, software, Holster, Lutetium test adapter, desktop holder, USB data cable, spare batteries, and rugged storage and carry case.
Unit Size-
4250812Spécifications complètes
EachRadEye SPRD-GN Personal Radiation Detector, includes software for configuring RadEye and Spectra downloadDemander un devis
Sensibilité(cps per μSv/h (662 keV)) 110
Mesure du bruit de fondNBR (Natural Background Rejection): Advanced with 6 Energy Windows
Certifications/ConformitéIP65
DescriptionRadEye SPRD-GN Personal Radiation Detector, includes software for configuring RadEye and Spectra download
Gamme d’énergie60 keV to 3 MeV (+/- 30%)
Type de batterie2 AAA
Plages de mesureDose Rate Range: 1 μR/h to 25 mR/h (10 nSv/h to 250 μSv/h)
CommunicationsWireless communications BT4 optional
Temps de réponseTypical ID-time @ 1μSv/h (100μR/h) ∼5 min
Type de détecteurCLYC (Cs2LiYCl6)
Poids (métrique)0.175 kg (including batteries and rubber sleeve)
Types d’alarmeNeutron Alarm Response: ANSI N42.48-2008: Yes (< 2 s)
Distance de chute sur le béton1.5 m
Type de radiationGamma, Neutron
Autonomie de la batterie∼120 hr.
Poids (impériale)0.385 lb. (including batteries and rubber sleeve)
Unit SizeEach
Affichage de 2 sur 2
  • Unprecedented size for gamma detection, gamma ID, and neutron detection
  • Single detector enables less complex design, superior field reliability, and reduced size & weight
  • Neutron alarms in <2 seconds and low false alarms exceeding ANSI specifications as well as lithium and He-3 based units
  • Patent pending source-less routines for ID stabilization and outstanding neutron sensitivity
  • Advanced NBR identifies artificial radiation while minimizing false alarms

Figures

Documentation et téléchargements

Certificats

    Foire aux questions (FAQ)

    Citations et références

    Search citations by name, author, journal title or abstract text