7500 Fast Real-Time PCR System, laptop
The discontinuation of sales for the 7500 and 7500 Fast real-time PCR for RUO starts on October 31, 2025. The 7500 Fast Dx was discontinued on December 31, 2022. Visit QuantStudio Real-Time PCR Systems for your qPCR instrument needs
Contact Us for more information
7500 Fast Real-Time PCR System, laptop
Applied Biosystems™

7500 Fast Real-Time PCR System, laptop

Le système de PCR en temps réel Applied Biosystems® 7500 Fast offre des performances maximales en un temps minimum. EntièrementAfficher plus
Have Questions?
RéférenceQuantité
43511061 system
Référence 4351106
Prix (EUR)
-
Demander un devis
Quantité:
1 system
Le système de PCR en temps réel Applied Biosystems® 7500 Fast offre des performances maximales en un temps minimum. Entièrement optimisé pour un cycle rapide, le 7500 Fast offre des résultats de haute qualité en seulement 30 minutes. Nous fournissons un ordinateur portable Dell™ doté du système 7500 Fast.

• Le Fast Block spécialement conçu garantit l’uniformité thermique à des vitesses importantes.
• Des vitesses de rampe plus rapides permettent des résultats rapides sans compromettre les temps d’extension ou la qualité des dosages.
• Les plaques optiques rapides garantissent une excellente précision dans les volumes de réaction 10-30 uL.
• Utilisez le Master Mix pour PCR TaqMan® Fast Universal pour exécuter plusieurs dosages Fast sur une seule plaque.
• Finissez davantage de cycles par jour grâce à l’excellente performance équivalente à celle offerte par le système 7500.

Analyse de fusion par haute résolution
Le logiciel de fusion par haute résolution (HRM) Applied Biosystems® est le plus facile d’utilisation pour utiliser le logiciel d’analyse de fusion et permet des dosages de courbe de fusion PCR en temps réel plus précis pour l’analyse de mutations et le génotypage. Le logiciel HRM est disponible sur le système de PCR en temps réel 7500 Fast, qui fournit des résultats précis dans un format standard de 96 puits.

Utilisez le logiciel de fusion par haute résolution (HRM) Applied Biosystems® pour effectuer une analyse de fusion plus sophistiquée avec un flux de travail facile à suivre et des étapes d’analyse de données subjectives minimales.

• Raccourcit le temps d’analyse en appelant automatiquement les génotypes et en omettant automatiquement les contrôles sans modèle.
• Minimise l’analyse subjective en regroupant automatiquement des clusters de variantes inconnus.
• Aucun changement de température requis – distinction plus facile entre les mutants homozygotes et le type sauvage.
• Permet de consulter facilement les données grâce à des vues multi-tracés personnalisables, des fenêtres extensibles et une affectation de couleurs en un clic pour mettre en évidence les courbes d’intérêt.
• Facilite la présentation des données grâce à l’option d’exportation de données et de graphiques directement dans PowerPoint ou sous forme de fichiers JPEG.

NOUVEAU - Logiciel 7500 v2.0
Maintenant, le logiciel StepOne facile à utiliser est disponible pour les systèmes 7500 et 7500 Fast avec la mise à niveau du logiciel 7500 v2.0. Le logiciel 7500 v2.0 intègre vos fonctions préférées du logiciel StepOne, telles que divers assistants de configuration de plaques, des calculateurs de dilution de courbe standard et de recette Master Mix, des indicateurs de CQ, des filtres de données et des notifications par e-mail lorsqu’un cycle est terminé. Le logiciel 7500 v2.0 comprend également un progiciel d’étude d’expression génétique amélioré et dispose d’une variété de nouvelles options de protocole de courbe de fusion, notamment la détection de pics multiples, le contrôle de la température d’étape et de maintien et les vitesses de montée personnalisables.

Le progiciel d’étude de l’expression génétique s’adapte mieux aux grosses études que tout autre progiciel d’instrument :
• Importez un nombre illimité de fichiers de CT comparative (quantification relative) dans une seule étude.
• Groupez les échantillons et visualisez les données par groupe de réplications techniques et par groupe de réplications biologiques.
• Utilisez n’importe quel(s) gène(s) comme contrôle endogène, y compris la moyenne de plusieurs contrôles ensemble.
• Entrez les valeurs d’efficacité connues à prendre en compte dans les résultats RG

Module 21 CFR Part 11 disponible
Le module SDS v1.4 21CFRP11 est un outil puissant pour aider à la conformité avec la norme 21CFRP11, tout en offrant la flexibilité des paramètres de configuration personnalisables par l’utilisateur.

• Des identifiants utilisateur individuels peuvent être ajoutés pour un maximum de quatre groupes d’utilisateurs, chaque groupe avec des paramètres d’autorisation désignés.
• Les paramètres d’autorisation personnalisables selon l’utilisateur incluent 14 activités système, l’attribution d’autorité de signature électronique et des paramètres de sécurité supplémentaires pour vous donner un contrôle maximal sur vos efforts de conformité.
• Les historiques d’expertise peuvent être activés ou désactivés en fonction de vos besoins de traçabilité.
• Une sélection de signatures électroniques est disponible pour faciliter les signatures électroniques dans votre flux de travaux.

Un seul système, de nombreuses applications
Les applications incluent l’analyse de l’expression génétique, la quantification des pathogènes, le génotypage SNP, les dosages isothermiques et +⁄– utilisant des contrôles positifs internes. Pour faciliter la plupart de ces applications, Applied Biosystems® fournit des dosages TaqMan® préformulés, prêts à l’emploi et soumis à un contrôle qualité pour une utilisation avec le système 7500 Fast. Vous pouvez maintenant réduire vos efforts d’optimisation des dosages.

Usage exclusivement réservé à la recherche. Ne pas utiliser pour des procédures de diagnostic.

Usage exclusivement réservé à la recherche. Ne pas utiliser pour des procédures de diagnostic.

Spécifications
Colorant étalonnéTAMRA, Cy3, FAM, SYBR Green, Texas Red, JOE, ROX, Cy5, NED, VIC
Dimensions34 cm (13.39 in.) (W) x 49 cm (19.29 in.) (H) x 45 cm (17.72 in.) (D)
Plage dynamique9 Logs of Linear Dynamic Range
Ordinateur externeLaptop Computer Provided
À utiliser avec (équipement)Système 7500 Fast
Format96-well Plate, 8-well Strips
Vitesse d’échauffement max. (bloc thermique)5.5°C
Éléments optiquesCCD Camera, Halogen Light Source, Five Excitation and Five Emission Filters
Colorant de référence passiveROX (Separate Tube), Other Passive Reference Dye, ROX (Pre-mixed)
Pic de montée en température du bloc5.5°C⁄s
PrécisionDistinguish between 5000 to 10,000 genome equivalents (two-fold Copy Number difference) with 99.7% Confidence
Quantité1 system
Vitesse de réactionRapide, standard
Plage de volume de réaction10–30 μL
Durée de fonctionnement36 min. (Fast), <2 hrs (Standard)
Montée en température des échantillonsFast Mode: ± 2.2°C⁄s, Standard mode: ± 1.6°C⁄s
SensibilitéDown to 1 Copy of Human RNAse P gene
Plage de températures (métrique)4,0 à 99,9°C
Précision thermique±0.5°C
Système de cyclage thermiqueSystème basé sur Peltier
Uniformité thermique±1°C
Cadence4 to 5 96-well Plates per day
Poids34 kg (75 lb.)
Capacité12 x 8-tube Strips, 1 x 96-well Plate (Fast)
Unit SizeEach
Contenu et stockage
Ordinateur portable

Foire aux questions (FAQ)

Why are there no RQ values for all the samples in my study from the 7500 or 7500 Fast Real-Time PCR System software?

The 7500 software requires that the endogenous control be run on every plate within a study. If not, you will only see RQ values for the plate that contains the endogenous control on it. The other plates will have CT values for all the wells, but the software will not calculate RQ values.

If you designed your experiments in this type of layout, you will want to do your analysis in the free DataAssist software instead. This program does not have the endogenous control requirement for every plate. Simply export the study results file from the 7500 software as a *.txt or *.csv file, and use that to create a new study in the DataAssist software. You should now be able to see RQ values for all samples, even those without an endogenous control on the same plate.

Find additional tips, troubleshooting help, and resources within our Real-Time PCR and Digital PCR Instruments Support Center.

Why do I not see any CT or RQ values from my ddCT experiment in the software for the 7500 or 7500 Fast Real-Time PCR System?

If you have the SDS v1.4 or earlier, you will need to open the dd CT plate in a Study first in order to see the CT or RQ values. (If you have v2.0.x this error does not apply.)

1.After the initial run is complete, open, review the plots and save it. Then:
-Choose File then New
-Choose: Assay then ddCT (Relative Quantitation) Study. Set the other parameters as appropriate and click Next.
2.Click on ‘Add Plates...', then browse to where your data file is located and select the plate (or multiple plates).
Click ‘Finish', and you should see your study.

Find additional tips, troubleshooting help, and resources within our Real-Time PCR and Digital PCR Instruments Support Center.

What can I do when I get the error message "Time too short" on the 7500 or 7500 Fast Real-Time PCR System?

You may encounter this error message, which will abort the run before it even starts. If so, go into the software under Setup then Run Method and check how much time has been set for the data collection step. The instrument has a minimum collection time, which is dependent on the number of filters being used. (This is true in both the 1.x and 2.0.x versions of the 7500 software.) Increase the extension time to 30 sec and restart the run. It should now proceed as normal. If the error persists, please contact us at techsupport@thermofisher.com for further assistance.

Find additional tips, troubleshooting help, and resources within our Real-Time PCR and Digital PCR Instruments Support Center.

What can I do if I get an error message about "Block Up Switch" on the 7500 or 7500 Fast Real-Time PCR System?

This error can be caused by the wrong plastics being used in the block, such as the wrong Precision Plate Holder being used in the tray. This can give an error message such as “Block up switch not activating” and will not allow the run to start. Open the drawer, make sure the correct plate/tubes and plate/tube holder are being used and in the correct orientation. Turn off the instrument and open the front cover to make sure the heated cover door is closed. Restart the instrument and retry the run. If the error still persists, please contact us at instrumentservices@thermofisher.com for further assistance.

Find additional tips, troubleshooting help, and resources within our Real-Time PCR and Digital PCR Instruments Support Center.

On the 7500 and 7500 Fast Real-Time PCR Systems, what can I do if I get an error message about "CCD acquisition failure"?

If you see this error message, please check the following:

1. Verify that the USB connection is secure between the instrument and computer.
2. Verify that the computer user power save settings are set to Never for all users (in Windows under Control Panel, Power Options).
3. Is there a screen saver in use? If so, set the screen saver so that it will not come on during a run.
4. Is there antivirus or other network software in use? If so, disconnect from the network while running the instrument.
If the error persists, please contact us at instrumentservices@thermofisher.com for further assistance.

Find additional tips, troubleshooting help, and resources within our Real-Time PCR and Digital PCR Instruments Support Center.

Citations et références (24577)

Citations et références
Abstract
Characterization of matrix metalloproteinase-2 and matrix metalloproteinase-9 and their inhibitors in equine granulosa cells in vivo and in vitro
Authors:Sessions, DR; Vick, MM; Fitzgerald, BP
Journal:JOURNAL OF ANIMAL SCIENCE
PubMed ID:
Matrix metalloproteinases (MMP) and tissue inhibitors of MMP (TIMP) regulate tissue remodeling events necessary for ovulation. Thus, changes in MMP and TIMP expression and protein enzyme activity were examined in vivo and in vitro during follicular development and atresia in the horse. Equine granulosa cells and follicular fluid from medium ... More
Molecular cloning and characterization of porcine calcineurin-alpha subunit expression in skeletal muscle.
Authors:Depreux FF, Scheffler JM, Grant AL, Bidwell CA, Gerrard DE
Journal:J Anim Sci
PubMed ID:19897633
The calmodulin/Ca(2+)-dependent serine/threonine phophatase, calcineurin (CaN), has been implicated in controlling muscle fiber phenotype. However, little information is available concerning the expression of CaN in porcine skeletal muscle. Therefore, the porcine CaN alpha (CaN-A) was cloned by reverse transcription-PCR and its expression characterized in selected porcine skeletal muscles. We successfully ... More
Cell lines as candidate reference materials for quality control of ERBB2 amplification and expression assays in breast cancer.
Authors:Xiao Y, Gao X, Maragh S, Telford WG, Tona A
Journal:Clin Chem
PubMed ID:19443566
BACKGROUND: Human epidermal growth factor receptor 2 (HER2) is an important biomarker whose status plays a pivotal role in therapeutic decision-making for breast cancer patients and in determining their clinical outcomes. Ensuring the accuracy and reproducibility of HER2 assays by immunohistochemistry (IHC) and by fluorescence in situ hybridization (FISH) ... More
Genetic analysis of hepatitis C virus with defective genome and its infectivity in vitro.
Authors:Sugiyama K, Suzuki K, Nakazawa T, Funami K, Hishiki T, Ogawa K, Saito S, Shimotohno KW, Suzuki T, Shimizu Y, Tobita R, Hijikata M, Takaku H, Shimotohno K
Journal:J Virol
PubMed ID:19369330
Replication and infectivity of hepatitis C virus (HCV) with a defective genome is ambiguous. We molecularly cloned 38 HCV isolates with defective genomes from 18 patient sera. The structural regions were widely deleted, with the 5' untranslated, core, and NS3-NS5B regions preserved. All of the deletions were in frame, ... More
HIV-1 transactivator protein induction of suppressor of cytokine signaling-2 contributes to dysregulation of IFN{gamma} signaling.
Authors:Cheng SM, Li JC, Lin SS, Lee DC, Liu L, Chen Z, Lau AS
Journal:Blood
PubMed ID:19279332
HIV infection remains a worldwide threat. HIV-1 transactivator protein Tat is one of the retroviral proteins identified as a key immunomodulator in AIDS pathogenesis. Although the primary function of Tat is to regulate HIV-1 replication in the infected cell, it also dysregulates cytokine production resulting in perturbation of the host ... More