TaqMan™ PreAmp Master Mix Kit
TaqMan™ PreAmp Master Mix Kit
TaqMan™ PreAmp Master Mix Kit
TaqMan™ PreAmp Master Mix Kit
TaqMan™ PreAmp Master Mix Kit
TaqMan™ PreAmp Master Mix Kit
Applied Biosystems™

TaqMan™ PreAmp Master Mix Kit

Étendez l’utilisation de vos précieux échantillons aux expériences de PCR en temps réel avec le kit mélange maître TaqMan® PreAmp.Afficher plus
Have Questions?
RéférenceQuantité
438426740 reactions
Référence 4384267
Prix (EUR)
2 585,00
Each
Quantité:
40 reactions
Prix (EUR)
2 585,00
Each
Étendez l’utilisation de vos précieux échantillons aux expériences de PCR en temps réel avec le kit mélange maître TaqMan® PreAmp. Le kit mélange maître Applied Biosystems® TaqMan® PreAmp contient le mélange maître TaqMan® PreAmp et le mélange maître d’expression génétique TaqMan®. Les deux fonctionnent ensemble pour offrir un flux de travaux transparent pour la préamplification et l’analyse quantitative d’ARNm.

Le kit mélange maître TaqMan® PreAmp vous permet :

• d’amplifier les cibles d’ADNc de façon égale sans introduire de biais ;
• d’analyser l’ARNm à partir d’échantillons précieux tels que les microdissections par capture laser, ponctions de biopsies et tissus enrobés de paraffine et fixés avec de la formaline (FFPE) ;
• de tirer le maximum de profit d’un échantillon d’ADNc pas plus lourd que 1 ng pour réaliser 200 réactions de PCR en temps réel, dans le cadre d’analyses de l’expression génétique, en utilisant les essais TaqMan® pour l’expression génétique
• d’analyser jusqu’à 100 cibles d’expression génétique avec des temps de manipulation minimum.

Préserve la régularité des cibles sans que la pré-amplification n’introduise de biais
Autrefois, les kits et techniques de pré-amplification étaient souvent responsables d’une amplification irrégulière des cibles et de données imprécises ou biaisées (comme le montraient les coefficients de corrélation faibles entre les échantillons amplifiés et non amplifiés). Le mélange maître TaqMan® PreAmp amplifie vos petits échantillons de départ sans biais et affiche une très grande corrélation entre l’ADNc amplifié et non amplifié.

Flux de travaux et résultats optimisés
Le mélange maître TaqMan® PreAmp et le mélange maître d’expression génétique TaqMan® fonctionnent en conjonction pour offrir un flux de travaux optimal pour l’analyse de petits échantillons de départ. Le mélange maître d’expression génétique TaqMan® permet une évaluation quantitative fiable sur 9 échelles dynamiques linéaires et a été validé par des dosages TaqMan®.
Usage exclusivement réservé à la recherche. Ne pas utiliser pour des procédures de diagnostic.
Spécifications
À utiliser avec (équipement)Système 7300, système 7500 Fast, système 7500, système 7900HT Fast
Hot StartFonctionnalité Hot-Start intégrée
Colorant de référence passiveSans ROX
PolyméraseADN polymérase AmpliTaq Gold
Gamme de produitsTaqMan
Type de produitKit de Master Mix PreAmp
Quantité40 reactions
Type d’échantillonADNc
Suffisant pour200 réactions
Méthode de détectionAmorce-sonde
GC-Rich PCR PerformanceÉlevé
Méthode PCRqPCR
Vitesse de réactionRapide ou standard
Unit SizeEach
Contenu et stockage
Contient un Master Mix TaqMan PreAmp 2X (1 ml), un Master Mix d’expression génétique TaqMan™ (5 ml) et une carte de référence rapide du kit Master Mix TaqMan™ PreAmp. Conserver les Master Mix à 2-8°C

La durée de conservation minimale garantie est de 60 jours (date de péremption exacte imprimée sur le produit et le certificat d’analyse).

Foire aux questions (FAQ)

Can I use preamplification with the TaqMan SNP Genotyping Assays?

There is a preamplification protocol included with our TaqMan Sample-to-SNP Kit. This is designed to work with a lysate sample.

How much template can I start with when using the TaqMan PreAmp Master Mix Kit?

The TaqMan PreAmp Master Mix Kit (P/N 4384267) is intended for use with very small quantities of cDNA (1 to 250 ng). This kit allows you to increase the quantity of specific cDNA targets for gene expression analysis using TaqMan Gene Expression Assays. Starting material is increased prior to PCR and the resulting preamplification product is then used for PCR. The TaqMan PreAmp Master Mix Kit enables multiplex preamplification of up to 100 targets at a time and provides unbiased amplification of specific amplicons for analysis with TaqMan Gene Expression Assays. For more detailed information on this kit, please refer to the TaqMan PreAmp Master Mix Kit Protocol (P/N 4384557).

What is the TaqMan PreAmp Master Mix Kit?

The TaqMan PreAmp Master Mix Kit (P/N 4384267) preamplifies small amounts of cDNA without introducing amplification bias to the sample. Preamplification enables you to stretch your limited sample into many more real-time PCR reactions. TaqMan PreAmp Master Mix Kit consists of TaqMan PreAmp Master Mix and the TaqMan Gene Expression Master Mix. The two work hand in hand to provide the best results in preamplification and quantitation of mRNA.

For more detailed information on this kit, please refer to the TaqMan PreAmp Master Mix Kit Protocol (P/N 4384557).

How does the SuperScript IV Single Cell/Low Input cDNA PreAmp Kit differ from TaqMan PreAmp Master Mix?

TaqMan PreAmp Master Mix is designed for targeted preamplification of up to 100 targets from small amounts of cDNA, while SuperScript IV Single Cell/Low Input cDNA PreAmp Kit allows global preamplification of full-length cDNA from single cells or low input RNA. It provides reagents for cell lysis, reverse transcription and preamplification steps.

Citations et références (52)

Citations et références
Abstract
Target genes of neuron-restrictive silencer factor are abnormally up-regulated in human myotilinopathy.
Authors:Barrachina M, Moreno J, Juves S, Moreno D, Olive M, Ferrer I
Journal:Am J Pathol
PubMed ID:17823282
Myotilinopathy is a subgroup of myofibrillar myopathies caused by mutations in the myotilin gene in which there is aggregation of abnormal cytoskeletal proteins and ubiquitin. We report here on the accumulation of neuron-related proteins such as ubiquitin carboxy-terminal hydrolase L1 (UCHL1), synaptosomal-associated protein 25, synaptophysin, and alpha-internexin in aberrant protein ... More
Differential expression of microRNA-675, microRNA-139-3p and microRNA-335 in benign and malignant adrenocortical tumours.
Authors:Schmitz KJ, Helwig J, Bertram S, Sheu SY, Suttorp AC, Seggewiss J, Willscher E, Walz MK, Worm K, Schmid KW
Journal:J Clin Pathol
PubMed ID:21471143
'Background For the clinical management of adrenocortical neoplasms it is crucial to correctly distinguish between benign and malignant tumours. Even histomorphologically based scoring systems do not allow precise separation in single lesions, thus novel parameters are desired which offer a more accurate differentiation. The tremendous potential of microRNAs (miRNAs) as ... More
Deletion of CD14 attenuates Alzheimer's disease pathology by influencing the brain's inflammatory milieu.
Authors:Reed-Geaghan EG, Reed QW, Cramer PE, Landreth GE
Journal:J Neurosci
PubMed ID:21084593
'Alzheimer''s disease (AD) is characterized by the deposition of beta-amyloid (Abeta)-containing plaques within the brain that is accompanied by a robust microglial-mediated inflammatory response. This inflammatory response is reliant upon engagement of innate immune signaling pathways involving the toll-like receptors (TLRs). Studies assessing the roles of TLRs in AD pathogenesis ... More
Anti-epithelial cell adhesion molecule antibodies and the detection of circulating normal-like breast tumor cells.
Authors:Sieuwerts AM, Kraan J, Bolt J, van der Spoel P, Elstrodt F, Schutte M, Martens JW, Gratama JW, Sleijfer S, Foekens JA
Journal:J Natl Cancer Inst
PubMed ID:19116383
'Identification of specific subtypes of circulating tumor cells in peripheral blood of cancer patients can provide information about the biology of metastasis and improve patient management. However, to be effective, the method used to identify circulating tumor cells must detect all tumor cell types. We investigated whether the five ... More
Altered GABAA receptor-mediated synaptic transmission disrupts the firing of gonadotropin-releasing hormone neurons in male mice under conditions that mimic steroid abuse.
Authors:Penatti CA, Davis MC, Porter DM, Henderson LP
Journal:J Neurosci
PubMed ID:20463213
'Gonadotropin-releasing hormone (GnRH) neurons are the central regulators of reproduction. GABAergic transmission plays a critical role in pubertal activation of pulsatile GnRH secretion. Self-administration of excessive doses of anabolic androgenic steroids (AAS) disrupts reproductive function and may have critical repercussions for pubertal onset in adolescent users. Here, we demonstrate that ... More