Modules sécables transparents Immuno
Modules sécables transparents Immuno
Modules sécables transparents Immuno
Modules sécables transparents Immuno
Modules sécables transparents Immuno
Thermo Scientific™

Modules sécables transparents Immuno

Choisissez parmi quatre surfaces et une variété de puits et de configurations grâce à ces modules immunologiques Breakable, qui offrent un choix optimal de produits pour le dosage spécifique.
Have Questions?
Modifier l'affichagebuttonViewtableView
RéférenceTraitement de surfaceType de puitsNb par paquetType de produit
446469MaxiSorpRond10Cadre
446442PolySorpRond5Cadre
446477PolySorpRond10Cadre
446490MultiSorpRond10Cadre
446639MaxiSorpRond10Barrette pour microplaques
473539PolySorpRond5Barrette pour microplaques
473768MaxiSorpRond5Barrette pour microplaques
95029390Universal Binding (UB, liaison universelle)Rond50Barrette pour microplaques
Référence 446469
Prix (EUR)
362,83
キャンペーン価格
543,00
Économisez 180,17 (33%)
Case of 60
Ajouter au panier
Traitement de surface:
MaxiSorp
Type de puits:
Rond
Nb par paquet:
10
Type de produit:
Cadre
Prix (EUR)
362,83
キャンペーン価格
543,00
Économisez 180,17 (33%)
Case of 60
Ajouter au panier

Choisissez parmi quatre surfaces et une variété de puits et de configurations grâce aux modules sécables Thermo Scientific™ Immuno qui offrent une parfaite fiabilité et reproductibilité d’un puits à l’autre et un choix optimal de produits pour le dosage spécifique.

Choisissez parmi les modules LockWell, BreakApart et Breakable 1x8 avec cadres standards 96 puits.
  • Pour dosages immunologiques en phase solide, p. ex. ELISA
  • Modules autostables faciles à manipuler
  • Système alphanumérique pour orientation aisée
  • Compatible avec les équipements standards
  • Qualité optique supérieure pour des résultats fiables
  • PS

Choix de surface :

  • Thermo Scientific™ PolySorp™, Immulon™ 1B et Universal Binding (UB) sont destinées à l’adsorption des molécules hydrophobes.
  • Thermo Scientific™ Medisorp™ et Immulon 2HB sont légèrement hydrophiles et lient une gamme variée de biomolécules.
  • Thermo Scientific™ MaxiSorp™, Immulon 4 HBX et Enhanced Binding (EB) sont hydrophiles et sont idéales pour les dosages d’anticorps par méthode sandwich.
  • Thermo Scientific™ MultiSorp™ est très hydrophile et adaptée aux glycanes et protéines solubles dans l’eau.
Garantie : 90 jours
Clause de non-responsabilité relative aux restrictions d’utilisation pour la recherche interne : Toute restriction applicable à l’acheteur et relative à l’utilisation du ou des produit(s) uniquement à des fins de recherche interne ne s’applique pas au(x) produit(s) présent(s) sur les pages Web associées à la présente déclaration.
Spécifications
Propriété de liaisonHydrophile
BreakApartBarrettes sécables
CertifiésOui
DescriptionQualité optique supérieure pour des résultats fiables
Méthode de détectionColorimétrique
À utiliser avec (application)Pour les dosages d’anticorps en sandwich
CouvercleSans couvercle
Nbre par carton60
Nb par paquet10
Conditionnement10 Paquets
Blocage de la plaqueAucun
Type de produitCadre
Quantité60/boîte
Molécule cibleAnticorps (glycoprotéines)
Volume (métrique) de travail250 μl
Modèle de puitsC8
Array8 x 12
CouleurTransparent
FormatPlaque à barrettes
MatériauPolystyrène
Nbre de puits96
StérilitéNon stérile
Traitement de surfaceMaxiSorp
Volume (métrique) du puits350 μl
Type de puitsRond
Unit SizeCase of 60

Foire aux questions (FAQ)

What length of peptide is ideal for binding to the Thermo Scientific MaxiSorp surface? What are the detection limitations?

We have tested and found that a 3 amino acid peptide (Pro, Leu, Gly) cannot be detected when passively adsorbed on the MaxiSorp surface. However, this peptide can be detected when covalently immobilized using CovaLink NH Modules and CovaLink NH2 Modules and Plates. Using covalent immobilization of small peptide residues, you can typically obtain a better orientation of the molecule and reduced problems with antibody recognition of the peptide due to masking of the epitope. We have discovered that a 7 amino acid peptide from the MHC Class II antigen can be detected when adsorbed on the MaxiSorp surface. We state that the detection limitation using the MaxiSorp surface is between 3 and 7 amino acid residues.
One additional note is that detection is contingent upon the orientation of the peptide when immobilized. If the active site is inactivated or hidden at the site facing the solid phase, no detection signal is observed.

Can I bind either single- or double-stranded DNA to the Thermo Scientific MaxiSorp surface?

Single-stranded DNA can be adsorbed to our MaxiSorp surface using approximately 10 µg ssDNA per mL PBS, pH 8.2, although the stability is uncertain. Based on our experience, ssDNA immobilized on the MaxiSorp surface is so loosely bound that it can be removed by stringent washing.
Double-stranded DNA will not bind to the MaxiSorp surface. DNA, however, can be covalently bound to Nunc NucleoLink Strips.

Are your Thermo Scientific 8-Well Strip Caps for Immuno Standard Modules compatible with LockWell modules?

Due to the locking feature design of the LockWell modules, the 8-Well Strip Caps for Immuno Standard Modules are not compatible with, and will not seal, the LockWell Modules.

For Nunc Immuno plates and modules, what are the advantages of one well geometry type over another? Which types should I use for various applications?

The following list describes the geometries of wells available for Nunc Immuno-plates and modules:
- Flat bottom (F): Allows maximum transmission of light. These plates can be read on a monochromatic reader.
- Round bottom (U): This geometry optimizes washing and coating. These plates can be read using a dual wavelength reader.
- "C" bottom (C): This design of the well is a combination of both flat and round bottoms. Basically, it is a flat bottomed well with curved edges at the bottom. These plates also can be read using a monochromatic reader combining optimal reading and washing.
- StarWell: These wells have a modified "C" shape geometry with eight fins strategically placed at the bottom. This feature increases surface area, allowing more molecules to become immobilized which reduces incubation times.

What is the difference between certified and non-certified MaxiSorp plates and modules?

Both of these surfaces are identical. The only difference between them is that for the certified plates, a representative sample from each manufacturing lot undergoes a Binding Capacity test. This test is an ELISA-like assay used in our quality control laboratories to ensure binding capabilities.