Thermo Scientific™

Plaques à 96 puits transparents en forme de C non stériles Immuno

Effectuez des immunoessais quantitatifs et qualitatifs en phase solide grâce à ces plaques à 96 puits non stériles, disponibles dans une grande variété de surfaces de liaison.
Have Questions?
Modifier l'affichagebuttonViewtableView
RéférenceTraitement de surfaceCertifiés
446612MaxiSorpOui
430341MaxiSorpNo
446140PolySorpNo
Référence 446612
Prix (EUR)
222,00
Case of 60
Traitement de surface:
MaxiSorp
Certifiés:
Oui
Prix (EUR)
222,00
Case of 60
Effectuez des immunoessais quantitatifs et qualitatifs en phase solide grâce aux plaques à 96 puits transparents en forme de C non stériles Thermo Scientific™ Immuno, qui incluent les plaques Nunc™, Immulon™ et Microtiter™. Choisissez parmi une variété de surfaces de liaison pour des dosages colorimétriques fiables et reproductibles.

Plaques à 96 puits pour matières solides :

  • Polystyrène transparent
  • Choix de plusieurs surfaces pour une liaison optimale
  • Rangs et colonnes avec étiquetage alphanumérique
  • Surfaces :

  • Thermo Scientific™ PolySorp™ pour l’adsorption des molécules hydrophobes
  • Les plaques Thermo Scientific™ MaxiSorp™ sont hydrophiles et parfaitement adaptées aux tests sur anticorps en sandwich.
  • Informations de commande :

    Remarque : la disponibilité peut varier d’un pays à l’autre. 446612, avec certificat.

    Un test fonctionnel de chaque lot est effectué pour la liaison des immunoglobulines IgG.

    Période de garantie limitée : Conformément à toutes les exigences et exclusions de la garantie définies dans nos modalités et conditions de vente, ce produit est garanti pendant un délai de quatre-vingt-dix (90) jours à compter de la date à laquelle nous expédions le produit.

    Clause de non-responsabilité en matière de restriction d’utilisation à des fins de recherche interne : Toutes les restrictions qui s’appliquent à l’acheteur dans le cadre de l’utilisation du/des produit(s) à des fins de recherche interne uniquement ne s’appliquent pas au(x) produit(s) sur les pages Web associées à cette déclaration.

    Clause de non-responsabilité relative aux restrictions d’utilisation pour la recherche interne : toutes les restrictions qui s’appliquent à l’acheteur dans le cadre de l’utilisation du/des produit(s) à des fins de recherche interne uniquement ne s’appliquent pas au(x) produit(s) sur les pages Web associées à cette déclaration.
    Spécifications
    Propriété de liaisonHydrophile
    CertifiésOui
    Méthode de détectionColorimétrique
    CouvercleSans couvercle
    Nbre par carton60
    Nb par paquet5
    Conditionnement60 boîtes
    Blocage de la plaqueAucun
    Type de produitMicroplaque
    Molécule cibleAnticorps (glycoprotéines)
    Volume (métrique) de travail250 μl
    Modèle de puitsC96
    Array8 x 12
    Code-barresAucun code-barres
    CouleurTransparent
    FormatÉtalon
    MatériauPolystyrène
    Nbre de puits96
    StérilitéNon stérile
    Traitement de surfaceMaxiSorp
    Type de puitsRond
    Unit SizeCase of 60

    Foire aux questions (FAQ)

    For Clear Flat-Bottom Immuno Nonsterile 96-Well Plates, is the surface treatment solely on the bottom of the well, or is it also applied to the sides?

    For energy treated plates, the entire plate surface receives the energy treatment. The MaxiSorp, PolySorp, MediSorp and MultiSorp plates are energy treated plates. For traditionally treated plates, the well surface is treated up to the listed working volume.

    What length of peptide is ideal for binding to the Thermo Scientific MaxiSorp surface? What are the detection limitations?

    We have tested and found that a 3 amino acid peptide (Pro, Leu, Gly) cannot be detected when passively adsorbed on the MaxiSorp surface. However, this peptide can be detected when covalently immobilized using CovaLink NH Modules and CovaLink NH2 Modules and Plates. Using covalent immobilization of small peptide residues, you can typically obtain a better orientation of the molecule and reduced problems with antibody recognition of the peptide due to masking of the epitope. We have discovered that a 7 amino acid peptide from the MHC Class II antigen can be detected when adsorbed on the MaxiSorp surface. We state that the detection limitation using the MaxiSorp surface is between 3 and 7 amino acid residues.
    One additional note is that detection is contingent upon the orientation of the peptide when immobilized. If the active site is inactivated or hidden at the site facing the solid phase, no detection signal is observed.

    Can I bind either single- or double-stranded DNA to the Thermo Scientific MaxiSorp surface?

    Single-stranded DNA can be adsorbed to our MaxiSorp surface using approximately 10 µg ssDNA per mL PBS, pH 8.2, although the stability is uncertain. Based on our experience, ssDNA immobilized on the MaxiSorp surface is so loosely bound that it can be removed by stringent washing.
    Double-stranded DNA will not bind to the MaxiSorp surface. DNA, however, can be covalently bound to Nunc NucleoLink Strips.

    For Nunc Immuno plates and modules, what are the advantages of one well geometry type over another? Which types should I use for various applications?

    The following list describes the geometries of wells available for Nunc Immuno-plates and modules:
    - Flat bottom (F): Allows maximum transmission of light. These plates can be read on a monochromatic reader.
    - Round bottom (U): This geometry optimizes washing and coating. These plates can be read using a dual wavelength reader.
    - "C" bottom (C): This design of the well is a combination of both flat and round bottoms. Basically, it is a flat bottomed well with curved edges at the bottom. These plates also can be read using a monochromatic reader combining optimal reading and washing.
    - StarWell: These wells have a modified "C" shape geometry with eight fins strategically placed at the bottom. This feature increases surface area, allowing more molecules to become immobilized which reduces incubation times.

    What is the difference between certified and non-certified MaxiSorp plates and modules?

    Both of these surfaces are identical. The only difference between them is that for the certified plates, a representative sample from each manufacturing lot undergoes a Binding Capacity test. This test is an ELISA-like assay used in our quality control laboratories to ensure binding capabilities.