Tampon de déshybridation de transfert Western Restore™ PLUS
Thermo Scientific™

Tampon de déshybridation de transfert Western Restore™ PLUS

Le tampon de déshybridation pour transfert Western Thermo Scientific Restore PLUS est une formule avancée pour retirer les anticorps secondairesAfficher plus
Have Questions?
Modifier l'affichagebuttonViewtableView
RéférenceQuantité
46430500 ml
4642830 ml
46430X44 x 500 mL
Référence 46430
Prix (EUR)
235,65
Online Exclusive
274,00
Économisez 38,35 (14%)
Each
Quantité:
500 ml
Grand volume ou format personnalisé
Prix (EUR)
235,65
Online Exclusive
274,00
Économisez 38,35 (14%)
Each
Le tampon de déshybridation pour transfert Western Thermo Scientific Restore PLUS est une formule avancée pour retirer les anticorps secondaires et primaires fixés aux membranes, ce qui permet de leur appliquer une nouvelle sonde et de les détecter avec des substrats chimiluminescents.

Caractéristiques du tampon de déshybridation pour transfert Western Restore PLUS :

Prêt à l’emploi et facile à utiliser —pas de dilution nécessaire ; pas d’odeurs désagréables ; à conserver à température ambiante
Compatible —s’utilise sur des membranes en nitrate de cellulose et PVDF, encore humides ou déjà sèches ; fonctionne avec quasiment tous les tampons de blocage, conjugués enzymatiques et substrats chimiluminescents
Économique —économise temps et échantillons ; déshybride les transferts efficacement dès la première fois
Robuste mais doux — les protéines transférées demeurent viables ; déshybride le même transfert cinq fois maximum
Flexible — déshybride et réhybride pour optimiser les concentrations d’anticorps ou pour détecter un nouvel antigène avec des anticorps différents

Le tampon Restore PLUS est une variation de la formulation originale du tampon de déshybridation pour transfert Western Thermo Scientific Restore. Le tampon de déshybridation Restore PLUS est à utiliser avec des anticorps difficiles à retirer des transferts Western et qui nécessitent de plus longues durées d’incubation ou des températures d’incubation supérieures à 22°C avec des formulations plus douces. Les anticorps haute affinité peuvent être retirés rapidement et efficacement des transferts Western à température ambiante sans retirer les protéines transférées, permettant plusieurs applications de sondes sur la cible.

Résumé du protocole :
• Laver le transfert pour retirer le substrat chimiluminescent
• Laisser incuber le transfert dans le tampon de déshybridation pour transfert Western Restore pendant 5 à 15 minutes à température ambiante
(ou incuber à 37°C pour les anticorps haute affinité)
• Retirer le transfert et laver dans du tampon de lavage
• Blocage des membrane
• Vérifier qu’il y a eu suffisamment d’anticorps retirés
• Effectuer l’expérience d’immunoempreinte suivante

Usage exclusivement réservé à la recherche. Ne pas utiliser pour des procédures de diagnostic.

Spécifications
Méthode de détectionChimiluminescence
À utiliser avec (application)Western Blot
FormeLiquide
Membrane CompatibilityNitrate de cellulose, PVDF
Gamme de produitsRestore
Type de produitTampon de déshybridation de transfert de protéines
Quantité500 ml
Unit SizeEach
Contenu et stockage
À la réception, conserver à température ambiante. Produit expédié à température ambiante.

Foire aux questions (FAQ)

How many times can I strip my blot using Restore or Restore Plus Western Blot Stripping Buffers ?

The stability of the attached (transferred and bound) protein will determine the number of times the membrane can be successfully re-probed after stripping. The protein may withstand stripping as many as four times or as few as one time.

Find additional tips, troubleshooting help, and resources within our Protein Electrophoresis and Western Blotting Support Center.

What is the proper wash buffer to use after stripping with Restore or Restore Plus Western Blot Stripping buffers?

Wash the membrane with the same buffer as was used between antibody probing steps during the Western blotting procedure.

Find additional tips, troubleshooting help, and resources within our Protein Electrophoresis and Western Blotting Support Center.

Can I strip membranes with Restore or Restore Plus Western Blot Stripping Buffer and reprobe for subsequent detection with fluorescent probes?

No. Although the fluorescent antibodies, like other antibodies, can be stripped with Restore Buffers, stripped membranes typically produce unacceptable background for subsequent fluorescent detection methods. We recommend Restore Fluorescent Western Blot Stripping Buffer, Cat. No. 62299 (20 mL) and Cat. No. 62300 (100 mL).

Note: Restore Fluorescent Western Blot Stripping Buffer is for use with low-fluorescence PVDF membrane (Cat. No. 22860) only.

Find additional tips, troubleshooting help, and resources within our Protein Electrophoresis and Western Blotting Support Center.

Will Restore and Restore Plus Western Blot Stripping Buffers remove biotin-bound avidin, streptavidin or NeutrAvidin Protein conjugates?

No. Restore and Restore Plus Buffers are not stringent enough to break the avidin-biotin interaction. A buffer capable of breaking this interaction would likely also damage the target protein, making it undetectable. However it may be possible to strip the complexed biotinylated primary antibody and streptavidin-HRP secondary antibody from the target protein on the membrane. Please also see Tech Tip: Strip and Reprobe Western Blots (https://assets.thermofisher.com/TFS-Assets/BID/Technical-Notes/strip-reprobe-western-blots-tech-tip.pdf).

Find additional tips, troubleshooting help, and resources within our Protein Electrophoresis and Western Blotting Support Center.

Will the Restore and Restore Plus Western Blot Stripping Buffers remove precipitating substrates?

No. The antibodies are removed but the substrate leaves a permanent precipitate on the membrane that cannot be removed. Restore and Restore Plus Buffers are designed for procedures using chemiluminescent substrates. Please note that this is not compatible with fluorescence supstrates as it will result in increased background. For fluorescent substrates please use our Restore Fluorescent Western Blot Stripping Buffer. Please also see Tech Tip: Strip and Reprobe Western Blots (https://assets.thermofisher.com/TFS-Assets/BID/Technical-Notes/strip-reprobe-western-blots-tech-tip.pdf).

Find additional tips, troubleshooting help, and resources within our Protein Electrophoresis and Western Blotting Support Center.