Modules Immuno standard transparents
Modules Immuno standard transparents
Modules Immuno standard transparents
Modules Immuno standard transparents
Modules Immuno standard transparents
Modules Immuno standard transparents
Modules Immuno standard transparents
Thermo Scientific™

Modules Immuno standard transparents

Travaillez sur des applications qui assurent une parfaite reproductibilité d’un puits à un autre grâce à ces modules immunologiques standard transparents. Compatibles avec les équipements standard.
Have Questions?
Modifier l'affichagebuttonViewtableView
RéférenceTraitement de surfaceVolume (métrique) de travailType de puitsModèle de puits
475086PolySorp250 μlRondU8
434797MaxiSorp350 μlRondF8
441653MaxiSorp250 μlRondC8
444865PolySorp250 μlRondC8
445101MaxiSorp250 μlRondC8
467120MediSorp350 μlRondF8
467140MultiSorp350 μlRondF8
467466MaxiSorp350 μlRondF16 (2x8 puits)
467679PolySorp350 μlRondF16
468667MaxiSorp350 μlRondF8
469078PolySorp350 μlRondF8
469264Hydrophile250 μlRondU16
469914MaxiSorp350 μlRondF16 (2x8 puits)
469922PolySorp350 μlRondF16 (2x8 puits)
469949MaxiSorp350 μlRondF8
469957PolySorp350 μlRondF8
473709MaxiSorp250 μlRondC12
473717PolySorp250 μlRondC12
475078MaxiSorp250 μlRondU8
6302Immulon 2 HB330 μlRondF12
6309Immulon 2 HB330 μlRondF12
6310Immulon 1 B330 μlRondF12
6405Immulon 4 HBX330 μlRondF12
95029100Meilleure capacité de liaison350 μlRondF8
6301TS1
également connu sous le numéro 6301
Immulon 1 B330 μlRondF12
Référence 475086
Prix (EUR)
459,87
Online Exclusive
537,00
Économisez 77,13 (14%)
Case of 60
Ajouter au panier
Traitement de surface:
PolySorp
Volume (métrique) de travail:
250 μl
Type de puits:
Rond
Modèle de puits:
U8
Prix (EUR)
459,87
Online Exclusive
537,00
Économisez 77,13 (14%)
Case of 60
Ajouter au panier

Travaillez sur des applications assurant une parfaite reproductibilité d’un puits à un autre grâce aux modules Immuno Thermo Scientific™ standard transparents équipés de plaques de module Nunc™, Immulon™ et Microtiter™ développées pour les techniques ELISA. Fabriqués pour être compatibles avec les équipements standard, ces modules apportent beaucoup de souplesse dans l’utilisation de composants avec petits volumes d’échantillons. Ils reposent sur les meilleures normes qualité et certifications du marché.

Caractéristiques :

  • Plusieurs formats de bandelettes : Bandelette de 8 puits, bandelette de 12 puits, bandelette de 16 puits (2 colonnes de 8 puits)
  • Plusieurs formes de puits : fond plat, fond en C (bords arrondis), puits en forme de U, puits StarWell (les puits sont dotés d’ailettes pour augmenter la surface et améliorer la performance)
  • Plusieurs surfaces pour optimiser la performance du dosage
  • Modules restant dans le cadre en cas de retournement
  • Cadre empilable doté de repères pour l’orientation du couvercle
  • Puits en polystyrène dans un cadre en polyéthylène
  • Tubulure externes : 128 × 86 mm

Choix de la surface :

  • Les plaques Thermo Scientific™ PolySorp™, Immulon™ 1B, et Universal Binding (UB) sont destinées à l’adsorption des molécules hydrophobes.
  • Les plaques Thermo Scientific™ Medisorp™ et Immulon 2HB sont légèrement hydrophiles et fixent divers types de biomolécules.
  • Les plaques Thermo Scientific™ MaxiSorp™, Immulon 4 HBX, et Enhanced Binding (EB) sont hydrophiles et idéales pour les dosages d’anticorps par méthode sandwich.
  • Les plaques Thermo Scientific™ MultiSorp™ sont très hydrophiles et conviennent bien aux glycanes et aux protéines hydrosolubles.

Informations de commande :

Les modules sont autonomes. Les références 95029440 et 464394 sont certifiées. Les cadres et les modules sont disponibles séparément. Du film adhésif et des bandelettes de bouchons sont disponibles. Des modules à code-couleur sont disponibles sur demande. Pour plus d’informations, veuillez contacter le service client ou un représentant commercial.

Garantie : 90 jours

Clause de non-responsabilité relative aux restrictions d’utilisation pour la recherche interne : toutes les restrictions qui s’appliquent à l’acheteur dans le cadre de l’utilisation du/des produit(s) à des fins de recherche interne uniquement ne s’appliquent pas au(x) produit(s) sur les pages Web associées à cette déclaration.
Spécifications
Propriété de liaisonHydrophobe
BreakApartNon
CertifiésNo
Méthode de détectionColorimétrique
Nbre par carton60
Nb par paquet10
Conditionnement60 boîtes
Blocage de la plaqueAucun
Type de produitBarrette pour microplaques
Quantité60/boîte
Molécule cibleLipides
Volume (métrique) de travail250 μl
Modèle de puitsU8
Array8 x 12
CouleurTransparent
FormatÉtalon
MatériauPS
Nbre de puits96
Traitement de surfacePolySorp
Type de puitsRond
Unit SizeCase of 60

Foire aux questions (FAQ)

What frames do you recommend for your Immuno Clear Standard Modules?

We recommend Frames and Accessories for Immuno Breakable Modules, BreakApart frame (Cat. No. 465404). This frame is designed to hold the Immuno Clear Standard Modules.

Are your Thermo Scientific 8-Well Strip Caps for Immuno Standard Modules compatible with all Nunc MicroWell 96-Well Microplates and Nunc Immuno 96-Well Plates?

Our Thermo Scientific 8-Well Strip Caps for Immuno Standard Modules were designed to provide a positive seal for flat and round bottom wells of our Nunc MicroWell 96-Well Microplates and Nunc Immuno 96-Well Plates.
8-Well Strip Caps for Immuno Standard Modules are not compatible with C or V bottom wells of the Nunc Microwell 96-Well Microplates and Nunc Immuno 96-Well Plates.

For Nunc Immuno plates and modules, what are the advantages of one well geometry type over another? Which types should I use for various applications?

The following list describes the geometries of wells available for Nunc Immuno-plates and modules:
- Flat bottom (F): Allows maximum transmission of light. These plates can be read on a monochromatic reader.
- Round bottom (U): This geometry optimizes washing and coating. These plates can be read using a dual wavelength reader.
- "C" bottom (C): This design of the well is a combination of both flat and round bottoms. Basically, it is a flat bottomed well with curved edges at the bottom. These plates also can be read using a monochromatic reader combining optimal reading and washing.
- StarWell: These wells have a modified "C" shape geometry with eight fins strategically placed at the bottom. This feature increases surface area, allowing more molecules to become immobilized which reduces incubation times.

Which surfaces do you recommend for RIA (radioimmunoassay)?

The choice of plates or modules will depend on the type of RIA you are planning to perform and specific assay conditions. Nunc provides two different surfaces for immunoassays, PolySorp and MaxiSorp.
- MaxiSorp surface is highly charged and should be used if the assay requires quantitative measurement of proteins (antibodies) or molecules with polar groups.
- PolySorp surface should be used if the assay consists of less polar molecules with hydrophobic characteristics.

Which 96-well Immuno plates or modules do you recommend for various applications?

The following list offers a brief description of the features of Nunc products and their specific applications:
- Nunc-Immuno Plates, MaxiSorp surface - These plates are designed for solid phase immuno assays and have a polystyrene surface with high affinity for polar groups and hydrophilic molecules. These 96-well plates are available with flat (F), round (U), or (C) bottom-well designs.
- Nunc-Immuno Plates, PolySorp surface - These plates have a polystyrene surface which adsorps less polar molecules compared to the MaxiSorp surface and has a high affinity for hydrophobic groups. These 96-well plates are available with flat (F), round (U), or (C) bottom-well designs.
- Nunc-Immuno Modules - These modules are designed for solid-phase immuno assays. The modules are available in 8-, 12- or 16-well formats with (F), (U), and (C) bottom-well and 8-well BreakApart with (C) bottom-well designs. These different formats allow one to choose the style which is appropriate for their assay design.
BreakApart Modules and LockWell Modules can be used for radioimmunoassays.
- Nunc StarWell Immuno Breakable Modules - The 8-well modules feature eight fins on the inner wall of the (C) bottom wells. This design increases the surface area by 50%. The increase in surface area allows more molecules to be immobilized, increasing assay signal. The fin configuration provides shorter diffusion distance to the surface, reducing incubation times.
- LockWell Immuno Breakable Modules - Each plate consists of 1 x 8 breakable strips. These strips are assembled in a designed frame which locks each well into place by a spring lock. This spring lock design orientates each well at the same horizontal level allowing uniform washing and reading. The LockWell Modules are available with round (U), (C) or StarWell bottom-well designs.
- Plates and Modules with (CovaLink) Covalent Binding Surfaces: These plates can be used to bind proteins, peptides, DNA or carbohydrates. Covalent linkage occurs via secondary amine group. This allows a specific orientation and provides improved stability compared to passive adsorption due to chemical binding between molecules. Binding of molecules on PolySorp and MaxiSorp surfaces is obtained by passive adsorption. CovaLink is a surface grafted with secondary amino groups (<NH) which serves as a bridge for covalent coupling. The covalent binding can immobilize small molecules such as biotin or peptides which may otherwise bind weakly by physical adsorption and facilitate the recognition by detection molecule.
- Nunc FluoroNunc/LumiNunc 96-Well Plates: These plates are optimized for IFMA (Immunofluorometric Assays) or FIA (Fluorometric Immuno Assays). The transparent polystyrene plates give a low background fluorescence and are optimal where a read-through system is used. The white plates/modules provide maximum reflection of fluorescence signal while maintaining low background. The white plates/modules are often used for epifluorescence reading. Black modules reduce background fluorescence and minimize back-scatter light which is often encountered in epifluorescence.