Modules Immuno standard blancs et noirs
Modules Immuno standard blancs et noirs
Modules Immuno standard blancs et noirs
Modules Immuno standard blancs et noirs
Modules Immuno standard blancs et noirs
Modules Immuno standard blancs et noirs
Modules Immuno standard blancs et noirs
Thermo Scientific™

Modules Immuno standard blancs et noirs

Réalisez des immunoessais par fluorescence et luminescence et des tests de liaison avec ces modules immunologiques standard noirs et blancs.
Have Questions?
Modifier l'affichagebuttonViewtableView
RéférenceCouleurVolume (métrique) du puitsTraitement de surface
475515Noir400 μlMaxiSorp
437591Blanc350 μlMaxiSorp
437702Blanc350 μlPolySorp
437915Transparent350 μlMaxiSorp
475523Noir400 μlPolySorp
7566Blanc380 μlHydrophobe
Référence 475515
Prix (EUR)
301,93
Online Exclusive
356,00
Économisez 54,07 (15%)
Case of 60
Ajouter au panier
Couleur:
Noir
Volume (métrique) du puits:
400 μl
Traitement de surface:
MaxiSorp
Prix (EUR)
301,93
Online Exclusive
356,00
Économisez 54,07 (15%)
Case of 60
Ajouter au panier
Effectuez des immunodosages par fluorescence et luminescence et des tests de liaison grâce aux modules Thermo Scientific™ Immuno standard blancs et noirs.
Caractéristiques :
  • Disponibles en bandelettes de 8, 12 ou 16 puits
  • Avec ou sans cadre pour choisir le dosage optimal
  • Puits à fond plat ou en forme de C
  • Choix de trois types de surface pour liaison optimale
  • Le format blanc offre une réflexion du signal extrêmement élevée et un faible bruit de fond en fluorescence ; recommandé pour l’épifluorescence
  • Le format noir réduit la rétrodiffusion de la lumière pouvant être observée en épifluorescence
  • Le format transparent ou incolore est à utiliser en fluorescence en temps résolu uniquement

Choix de la surface :

  • Thermo Scientific™ PolySorp™ et Microlite™ 1+ sont destinés à l’adsorption des molécules hydrophobes.
  • Microlite 2+ est légèrement hydrophile et se lie à une grande variété de biomolécules.
  • La plaque Thermo Scientific™ MaxiSorp™ est hydrophile et idéale pour les dosages d’anticorps par méthode sandwich.
Garantie : 90 jours
Clause de non-responsabilité relative aux restrictions d’utilisation pour la recherche interne : toutes les restrictions qui s’appliquent à l’acheteur dans le cadre de l’utilisation du/des produit(s) à des fins de recherche interne uniquement ne s’appliquent pas au(x) produit(s) sur les pages Web associées à cette déclaration.
Spécifications
Propriété de liaisonHydrophile
Type de liaisonAdsorption
BreakApartNon
CertifiésOui
Méthode de détectionFluorescence
À utiliser avec (application)Fluorescence
Nbre par carton60
Nb par paquet5
Conditionnement60 boîtes
Blocage de la plaqueAucun
Type de produitBarrette pour microplaques
Molécule cibleAnticorps (glycoprotéines)
Volume (métrique) de travail350 μl
Array8 x 12
CouleurNoir
FormatÉtalon
MatériauPS
Nbre de puits96
Traitement de surfaceMaxiSorp
Volume (métrique) du puits400 μl
Type de puitsRond
Unit SizeCase of 60

Foire aux questions (FAQ)

What length of peptide is ideal for binding to the Thermo Scientific MaxiSorp surface? What are the detection limitations?

We have tested and found that a 3 amino acid peptide (Pro, Leu, Gly) cannot be detected when passively adsorbed on the MaxiSorp surface. However, this peptide can be detected when covalently immobilized using CovaLink NH Modules and CovaLink NH2 Modules and Plates. Using covalent immobilization of small peptide residues, you can typically obtain a better orientation of the molecule and reduced problems with antibody recognition of the peptide due to masking of the epitope. We have discovered that a 7 amino acid peptide from the MHC Class II antigen can be detected when adsorbed on the MaxiSorp surface. We state that the detection limitation using the MaxiSorp surface is between 3 and 7 amino acid residues.
One additional note is that detection is contingent upon the orientation of the peptide when immobilized. If the active site is inactivated or hidden at the site facing the solid phase, no detection signal is observed.

Can I bind either single- or double-stranded DNA to the Thermo Scientific MaxiSorp surface?

Single-stranded DNA can be adsorbed to our MaxiSorp surface using approximately 10 µg ssDNA per mL PBS, pH 8.2, although the stability is uncertain. Based on our experience, ssDNA immobilized on the MaxiSorp surface is so loosely bound that it can be removed by stringent washing.
Double-stranded DNA will not bind to the MaxiSorp surface. DNA, however, can be covalently bound to Nunc NucleoLink Strips.

Are your Thermo Scientific 8-Well Strip Caps for Immuno Standard Modules compatible with all Nunc MicroWell 96-Well Microplates and Nunc Immuno 96-Well Plates?

Our Thermo Scientific 8-Well Strip Caps for Immuno Standard Modules were designed to provide a positive seal for flat and round bottom wells of our Nunc MicroWell 96-Well Microplates and Nunc Immuno 96-Well Plates.
8-Well Strip Caps for Immuno Standard Modules are not compatible with C or V bottom wells of the Nunc Microwell 96-Well Microplates and Nunc Immuno 96-Well Plates.

For Nunc Immuno plates and modules, what are the advantages of one well geometry type over another? Which types should I use for various applications?

The following list describes the geometries of wells available for Nunc Immuno-plates and modules:
- Flat bottom (F): Allows maximum transmission of light. These plates can be read on a monochromatic reader.
- Round bottom (U): This geometry optimizes washing and coating. These plates can be read using a dual wavelength reader.
- "C" bottom (C): This design of the well is a combination of both flat and round bottoms. Basically, it is a flat bottomed well with curved edges at the bottom. These plates also can be read using a monochromatic reader combining optimal reading and washing.
- StarWell: These wells have a modified "C" shape geometry with eight fins strategically placed at the bottom. This feature increases surface area, allowing more molecules to become immobilized which reduces incubation times.

What is the difference between certified and non-certified MaxiSorp plates and modules?

Both of these surfaces are identical. The only difference between them is that for the certified plates, a representative sample from each manufacturing lot undergoes a Binding Capacity test. This test is an ELISA-like assay used in our quality control laboratories to ensure binding capabilities.