SMART Digest RNase Columns
SMART Digest RNase Columns
Thermo Scientific™

SMART Digest RNase Columns

Thermo Scientific SMART Digest™ RNase Columns provide simple, fast and highly reproducible digestion of ribonucleic acid (RNA) to enable oligonucleotide mapping and quantitation.

Have Questions?
Modifier l'affichagebuttonViewtableView
RéférenceEnzymes
60140-101RNase T1
60140-102RNase A
Référence 60140-101
Prix (EUR)
1 554,37
Each
Ajouter au panier
Enzymes:
RNase T1
Prix (EUR)
1 554,37
Each
Ajouter au panier

Thermo Scientific SMART Digest Immobilized Ribonucleases (Rnases) Columns are designed using the same proven technology as the Thermo Scientific SMART Digest Rnase kits to provide simple, fast and highly reproducible digestion of ribonucleic acid (RNA) in a flow through format.

Obtain high-quality analytical results from mRNA digestions using SMART Digest RNase columns. A significant advance in sample preparation for oligonucleotide mapping, the columns provide fast, simple digestion with high levels of reproducibility, RNase columns use immobilized ribonucleases which allow control of partial digestion to produce required fragments of ideal length for sequencing by HRAM-MS.

Easy and simple

  • Simple process allows control of digestion time ensuring required fragment length for comprehensive mRNA sequencing by HRAM MS
  • Single nuclease digestion allows full characterization of mRNA

Reliable results

  • Increased reproducibility over existing protocols
  • Higher data confidence
  • No nuclease contamination of the analytical column

RNase columns are available with two enzyme specificities:

  • RNase T1 is an endoribonuclease that specifically degrades single-stranded RNA at G residues
  • RNase A is an endoribonuclease that specifically degrades single-stranded RNA at C and U residues
Spécifications
Format de colonneImmobilized enzyme
Type de colonneImmobilized enzyme in PEEK cartridge
DescriptionSMART Digest RNase T1 column
Diamètre2.1 mm
Débit10 to 500 μL/min
À utiliser avec (application)Oligionucleotide Mapping
Longueur30 mm
Pression max.2500 psi (170 bar)
Compatibilité de phase mobileAmmonium acetate or Tris without saline
Plages de températures de fonctionnement20 °C to 50°C
Matériau de remplissageHydrophilic/coated DVB
Granulométrie˜20 μm
Porosité> 1000Å
Stabilité3 years
Phase stationnaireImmobilized enzyme
Température de stockage4 °C for extended period of time (refrigerate in Tris without Saline)
TechniqueBioLC
Poids8 g
CleavageDegrades single-stranded RNA at G residues
EnzymesRNase T1
TypeSMART Digest RNase T1 column
pH7 to 8.5
Unit SizeEach