Substrat de sensibilité SuperSignal™ West Atto Ultimate
Substrat de sensibilité SuperSignal™ West Atto Ultimate
Thermo Scientific™

Substrat de sensibilité SuperSignal™ West Atto Ultimate

Le substrat chimiluminescent ultrasensible SuperSignal West Atto est un substrat chimiluminescent optimisé (ECL) ultrasensible afin de détecter une quantité protéiqueAfficher plus
Have Questions?
Modifier l'affichagebuttonViewtableView
RéférenceQuantité
A3855420 ml
A38555100 ml
A38556200 ml
Référence A38554
Prix (EUR)
125,65
キャンペーン価格
149,00
Économisez 23,35 (16%)
Each
Ajouter au panier
Quantité:
20 ml
Prix (EUR)
125,65
キャンペーン価格
149,00
Économisez 23,35 (16%)
Each
Ajouter au panier
Le substrat chimiluminescent ultrasensible SuperSignal West Atto est un substrat chimiluminescent optimisé (ECL) ultrasensible afin de détecter une quantité protéique en attogramme élevée. Le substrat SuperSignal West Atto offre la plus haute sensibilité possible et un rapport signal/bruit supérieur aux autres substrats de peroxydase de raifort (HRP) hautes performances disponibles dans le commerce.

Caractéristiques des substrats chimiluminescents ultrasensible SuperSignal West Atto :
• Sensibilité : d’un femtogramme réduit à un attogramme élevé
• Stabilité : 48 heures pour une solution de travail, un an pour un kit à 4°C
• Compatibilité : membranes en nitrate de cellulose et en PVDF
• Durée du signal : jusqu’à six heures
• Concentration d’anticorps primaires recommandée : –dilution de 1:1 000 à 1:5 000 (0,2–1,0 µg/ml)
• Concentration d’anticorps secondaires recommandée : dilution de 1:100 000 à 1:250 000 (4–10 ng/ml)

Comparez et apprenez-en plus sur nos substrats chimiluminescents pour transfert Western ›
Consultez tous les substrats HRP disponibles ›

Le substrat chimiluminescent ultrasensible SuperSignal West Atto est conçu pour produire une sensibilité et un rapport signal/bruit supérieur pour des cibles très peu abondantes ou des échantillons précieux lors des analyses par transfert Western. Associé aux concentrations optimisées d’anticorps et aux tampons de blocage, le substrat SuperSignal West Atto permet de détecter les protéines cibles en quantités trop faibles afin qu’elles soient visibles avec des substrats ECL hautes performances typiques.
Usage exclusivement réservé à la recherche. Ne pas utiliser pour des procédures de diagnostic.
Spécifications
Contenus des kitsLuminol/Enhancer, 10 mL, Stable Peroxide Buffer, 10 mL
SensibilitéFemtogramme réduit à l’attogramme élevé
Conditions d’expéditionGlace humide
Suffisant pour2 transferts sur mini-gels, 200 cm2 de membrane
Méthode de détectionChimiluminescence
À utiliser avec (application)Western Blot
FormeLiquide
Membrane CompatibilityNitrate de cellulose, PVDF
Gamme de produitsSuperSignal
Type de produitSubstrat
Quantité20 ml
SubstratePeroxydase de raifort
Unit SizeEach
Contenu et stockage
• Solution de substrat, 10 ml
• Solution de peroxyde stable, 10 ml

Quantité suffisante pour deux transferts de mini-gels ; 200 cm2 de membrane.

Conserver les réactifs entre 2 et 8°C.

Foire aux questions (FAQ)

How do I handle saturated or burned out bands using SuperSignal West Atto Ultimate Sensitivity Substrate?

Here are some suggestions:
- Shorten the time of exposure
- Wash blot and try using SuperSignal West Pico PLUS Chemiluminescent Substrate
- Strip the membrane using Restore Western Blot Stripping Buffer, re-probe with lesser amount of primary and secondary antibodies, and try first with SuperSignal West Pico PLUS Chemiluminescent Substrate
- Re-run the gel using lesser sample

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

How can I reduce background with SuperSignal West Atto Ultimate Sensitivity Substrate?

Here are potential causes for high background and corresponding solutions:
- Too much HRP in the system: Further dilute the HRP-conjugate, see guidelines in Table 1 in the user guide (https://assets.thermofisher.com/TFS-Assets/LSG/manuals/MAN0018858_SuperSignalWestAtto_UG.pdf).
- Inadequate blocking: Optimize blocking conditions.
- Inappropriate blocking reagent: Try a different blocking reagent. Use clear milk or StartingBlock blocking buffer instead of dry milk.
- Inadequate washing: Increase length, number or volume of washes.
- Film has been overexposed: Decrease exposure time or use Pierce Background Eliminator (Cat No. 21065).
- Concentration of antigen or antibody is too high: Decrease amount of antigen or antibody.
- Poor antibody specificity: Use SuperSignal Western Blot Enhancer (Cat. No. 46640).
We also recommend minimizing handling of the membrane, using clean gloves while handling, clean plasticware, glassware, forceps, or other contact surfaces. We also recommend trimming of the membrane to remove excess area.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

Is SuperSignal West Atto Ultimate Sensitivity Substrate compatible with Restore Western Blot Stripping Buffer?

SuperSignal West Atto Ultimate Sensitivity Substrate is compatible with Restore Western Blot Stripping Buffer.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

When should I use SuperSignal West Atto Ultimate Sensitivity Substrate?

We recommend using SuperSignal West Atto Ultimate Sensitivity Substrate for detection of proteins in the following situations:
- For proteins with low concentration, not measurable by BCA or Bradford assays
- For low-abundance phosphorylated or glycosylated proteins
- For low-abundance membrane or nuclear proteins
- For low-abundance proteins being detected with a low-affinity antibody or when the antibody is precious
- When sample source is limited or when multiple conditions or assays are being tested on a single sample

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

Is SuperSignal West Atto Ultimate Sensitivity Substrate affected by freeze/thaw cycles?

SuperSignal West Atto Ultimate Sensitivity Substrate can tolerate up to 3 freeze/thaw cycles without significant loss in performance.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.