FluoSpheres™ Carboxylate-Modified Microspheres
Invitrogen™

FluoSpheres™ Carboxylate-Modified Microspheres

Réalisez la fluorescence la plus brillante grâce aux microsphères FluoSphere modifiées au carboxylate, disponibles dans différentes couleurs et tailles de particules.
Have Questions?
Modifier l'affichagebuttonViewtableView
RéférenceDiamètre (métrique)CouleurExcitation / émissionQuantité
F88030,1 μmJaune-vert505/515 nm10 mL
F88161,0 μmCramoisi625/645 nm2 mL
F88231,0 μmJaune-vert505/515 nm10 mL
F88010,1 μmRouge580/605 nm10 mL
F88110,2 μmJaune-vert505/515 nm10 mL
F88070,2 μmRouge foncé660/680 nm2 mL
F107200,04 μmVert jaune, Orange, Rouge, Rouge foncé505 / 515, 540 / 560, 580 / 605, 660 / 680 nm1 ml (chacun)
F208810,2 μmOrange365/610 nm2 mL
F8783
également connu sous le numéro F-8783
0,02 μmRouge foncé660/680 nm2 mL
F87860,02 μmCouleur rouge580/605 nm10 mL
F8795
également connu sous le numéro F-8795
0,04 μmVert jaune505/515 nm1 mL
F88130,5 μmJaune-vert505/515 nm10 mL
F88201,0 μmOrange540/560 nm10 mL
F88252,0 μmRouge du Nil535/575 nm2 mL
F88272,0 μmJaune-vert505/515 nm2 mL
F8781
également connu sous le numéro F-8781
0,02 μmBleu365/415 nm10 mL
F8782
également connu sous le numéro F-8782
0,02 μmCramoisi625/645 nm2 mL
F87840,02 μmRouge du Nil535/575 nm10 mL
F87870,02 μmJaune-vert505/515 nm10 mL
F8789
également connu sous le numéro F-8789
0,04 μmRouge foncé660/680 nm1 mL
F8792
également connu sous le numéro F-8792
0,04 μmOrange540/560 nm1 mL
F87930,04 μmCouleur rouge580/605 nm1 mL
F87940,04 μmRouge-orange565/580 nm1 mL
F87970,1 μmCouleur bleue350/440 nm10 mL
F87990,1 μmInfrarouge715/755 nm1 mL
F8800
également connu sous le numéro F-8800
0,1 μmOrange540/560 nm10 mL
F88050,2 μmCouleur bleue365/415 nm10 mL
F88060,2 μmCramoisi625/645 nm2 mL
F88090,2 μmOrange540/560 nm10 mL
F88100,2 μmRouge580/605 nm10 mL
F88120,5 μmRouge580/605 nm10 mL
F88141,0 μmCouleur bleue365/415 nm10 mL
F88151,0 μmCouleur bleue350/440 nm10 mL
F88191,0 μmRouge du Nil535/575 nm10 mL
F88211,0 μmRouge580/605 nm10 mL
F8824
également connu sous le numéro F-8824
2,0 μmCouleur bleue365/415 nm2 mL
F88262,0 μmCouleur rouge580/605 nm2 mL
Référence F8803
Prix (EUR)
728,00
Each
Diamètre (métrique):
0,1 μm
Couleur:
Jaune-vert
Excitation / émission:
505/515 nm
Quantité:
10 mL
Prix (EUR)
728,00
Each

Exécutez facilement cytométrie en flux, microscopie, HTS, HCS, immunodosage et autres applications de laboratoire grâce à notre vaste sélection de microsphères FluoSphere modifiées au carboxylate. Les microbilles FluoSphere peuvent être utilisées pour l’adsorption passive ou active, le couplage covalent de protéines, d’acides nucléiques et de biomolécules pour les applications de capture de particules. Les microsphères FluoSphere sont chargées avec des colorants fluorescents exclusifs, ce qui en fait les microsphères les plus brillantes disponibles.

Visualisez la fluorescence la plus brillante pour les applications de laboratoire, notamment la microscopie par fluorescence, la cytométrie en flux, le HTS, le HCS et le traçage cellulaire, grâce à nos microsphères FluoSphere modifiées au carboxylate, fabriquées à partir de microsphères en polystyrène et chargées avec différents colorants exclusifs. Grâce à des méthodes de coloration spécialisées, toutes les molécules de colorants fluorescents sont contenues à l’intérieur de chaque microsphère en polystyrène, au lieu de se trouver à la surface des microbilles. Cet environnement protecteur dans les microbilles protège le colorant contre les effets environnementaux préjudiciables, tels que le photoblanchiment. Nos microsphères modifiées au carboxylate sont revêtues d’un polymère hydrophile contenant plusieurs acides carboxyliques pour l’adhérence covalente des ligands. Une variété de tailles de particules sont disponibles pour différentes utilisations et expériences de recherche.
For Research Use Only. Not for use in diagnostic procedures.
Spécifications
Excitation / émission505/515 nm
Gamme de produitsFLUOSPHERES
Quantité10 mL
Modification de surfaceCarboxylate
CouleurJaune-vert
Diamètre (métrique)0,1 μm
À utiliser avec (application)Microscopie par fluorescence
MatériauPolystyrène
Type de produitMicrosphère au carboxylate modifié
Unit SizeEach
Contenu et stockage
Conserver au réfrigérateur (entre 2 et 8°C) à l’abri de la lumière.

Foire aux questions (FAQ)

I have some FluoSpheres polystyrene microspheres, with 20 nm diameter. They are aggregating a lot. What can I do about it?

The smaller the microspheres, the greater the propensity to aggregate. But the aggregation is not irreversible. Sonicate in a bath sonicator or vortex to disperse, just prior to use. You can also add a small concentration of Tween-20 or Triton X-100 (unless you are using them in a live-cell system).

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

I sonicated my 2.0 µm carboxylate-modified microspheres, as recommended, but saw foaming (bubbles) on top of the solution. Should I be concerned?

Use of a bath sonicator is recommended to help break up any aggregated microspheres. The foaming is from Tween-20, which is in the stock solution to help prevent aggregation. It is normal and expected to see bubbles from this. Do not use a probe sonicator, which would cause damage to the microspheres (as well as much more bubbling).

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

When does the warranty guarantee expire for FluoSpheres Carboxylated-Modified Microspheres?

FluoSpheres Carboxylate-Modified Microspheres (Cat. Nos. F8783, F8786, F8801, F8807, F8811, F8803, F8816, F8823, F20881, F10720) have a 1-year warranty guarantee, unless otherwise indicated on the Certificate of Analysis (COA).

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

What is the warranty for FluoSpheres microspheres?

The warranty period for FluoSpheres microspheres is 1-year from the date of shipment.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

After washing and centrifugation, there was only a very small pellet left of my microsphere beads and the solution was transparent. Why is this?

Centrifugation is not an effective way to collect smaller microspheres; many particles remain in the solution even if you can visualize a small pellet. For beads less than 1 µm in diameter, we recommend washing by either:

Cross-flow filtration, as these particles have a very high compression modulus and can withstand high g-forces without risk of harm or dialysis with a 500 kDa MWCO
Note: Microspheres greater than 1 µm in diameter can be centrifuged at 1,300 rpm.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

Citations et références (22)

Citations et références
Abstract
Three-dimensional resolution doubling in wide-field fluorescence microscopy by structured illumination.
Authors:Gustafsson MG, Shao L, Carlton PM, Wang CJ, Golubovskaya IN, Cande WZ, Agard DA, Sedat JW,
Journal:Biophys J
PubMed ID:18326650
'Structured illumination microscopy is a method that can increase the spatial resolution of wide-field fluorescence microscopy beyond its classical limit by using spatially structured illumination light. Here we describe how this method can be applied in three dimensions to double the axial as well as the lateral resolution, with true ... More
The power of single and multibeam two-photon microscopy for high-resolution and high-speed deep tissue and intravital imaging.
Authors:Niesner R, Andresen V, Neumann J, Spiecker H, Gunzer M,
Journal:Biophys J
PubMed ID:17557785
'Two-photon microscopy is indispensable for deep tissue and intravital imaging. However, current technology based on single-beam point scanning has reached sensitivity and speed limits because higher performance requires higher laser power leading to sample degradation. We utilize a multifocal scanhead splitting a laser beam into a line of 64 foci, ... More
Role of glycocalyx in leukocyte-endothelial cell adhesion.
Authors:Mulivor AW, Lipowsky HH
Journal:Am J Physiol Heart Circ Physiol
PubMed ID:12234777
'The binding of fluorescently labeled microspheres (FLMs, 0.1-microm diameter) coated with antibody (1a29) to ICAM-1 was studied in postcapillary venules during topical application of the chemoattractant N-formylmethionyl-leucyl-phenylalanine (fMLP). FLM adhesion to endothelial cells (ECs) increased dramatically from 50 to 150 spheres per 100-microm length of venule after superfusion of the ... More
a2 Adrenergic receptor-mediated inhibition of thermogenesis.
Authors:Madden CJ, Tupone D, Cano G, Morrison SF,
Journal:J Neurosci
PubMed ID:23365239
'a2 adrenergic receptor (a2-AR) agonists have been used as antihypertensive agents, in the management of drug withdrawal, and as sedative analgesics. Since a2-AR agonists also influence the regulation of body temperature, we explored their potential as antipyretic agents. This study delineates the central neural substrate for the inhibition of rat ... More
Glucoprivation in the ventrolateral medulla decreases brown adipose tissue sympathetic nerve activity by decreasing the activity of neurons in raphe pallidus.
Authors:Madden CJ,
Journal:Am J Physiol Regul Integr Comp Physiol
PubMed ID:22071154
'In urethane/a-chloralose anesthetized rats, cold exposure increased brown adipose tissue sympathetic nerve activity (BAT SNA: +699 ± 104% control). Intravenous administration of 2-deoxy-D-glucose (2-DG; 200 mg·ml(-1)·kg(-1)) reversed the cold-evoked activation of BAT SNA (nadir: 139 ± 36% of control) and decreased BAT temperature (-1.1 ± 0.2°C), expired CO(2) (-0.4 ± ... More