Milieu de montage anti-atténuation ProLong™ Diamond
Milieu de montage anti-atténuation ProLong™ Diamond
Milieu de montage anti-atténuation ProLong™ Diamond
Milieu de montage anti-atténuation ProLong™ Diamond
Invitrogen™

Milieu de montage anti-atténuation ProLong™ Diamond

Le milieu de monteur anti-atténuation ProLong Diamond Antifade est un milieu de montage liquide à base de glycérol appliqué directementAfficher plus
Have Questions?
Modifier l'affichagebuttonViewtableView
RéférenceQuantité
P3697010 ml
P369652 ml
P369615 x 2 ml
Référence P36970
Prix (EUR)
312,65
Online Exclusive
351,00
Économisez 38,35 (11%)
Each
Ajouter au panier
Quantité:
10 ml
Prix (EUR)
312,65
Online Exclusive
351,00
Économisez 38,35 (11%)
Each
Ajouter au panier
Le milieu de monteur anti-atténuation ProLong Diamond Antifade est un milieu de montage liquide à base de glycérol appliqué directement sur les échantillons de tissus ou de cellules marqués par fluorescence sur lame de microscope. Il est formulé sans coloration d’ADN ou avec la coloration d’ADN bleue DAPI ou avec la coloration d’ADN rouge profond SYTOX. Le milieu de montage ProLong Diamond est conçu pour assurer une protection inégalée contre les atténuations sur l’ensemble du spectre visuel et IR. Vous pouvez utiliser le milieu de monteur ProLong Diamond avec presque tous les colorants ou protéines fluorescents (par ex., GFP, RFP, mCherry) afin d’obtenir le signal le plus lumineux et le fond le plus ténu possibles, et obtenir ainsi des images fluorescentes brillantes et de haute définition.

Caractéristiques du milieu de monteur ProLong Diamond Antifade :
• protège les colorants fluorescents et les protéines fluorescentes de la décoloration, sur l'ensemble des spectres visibles et IR
•. Liquide prêt à l'emploi qui durcit pour le stockage à long terme
• Idéal pour Alexa Fluor et les colorants traditionnels, tels que FITC et Cy3, et les protéines fluorescentes comme GFP, RFP, et les
• échantillons montés sur mCherry sont stables pendant des mois
• Conserve le signal de fluorescence —faible à aucune extinction

En savoir plus sur les monteurs Antifade ProLong.

Pour les monteurs avec indice de réfraction 1,52, optimisé pour l'imagerie objective d'immersion dans l'huile, essayez de durcir le monteur Monteur antifade en verre Prolong ou montant antifade en verre SlowFade non durcissant.

Le montant allongé Diamond Antifade est déjà mélangé et prêt à l'emploi dans un flacon compte-gouttes ou dans un flacon de 10 ml avec ou sans coloration de l'ADN. La coloration DAPI est excitée par lumière UV à 360 nm en cas de liaison à l’ADN avec un maximum d’émission à 460 nm et est détectée à l’aide d’un filtre DAPI classique. La coloration rouge profond SYTOX est excitée par la lumière rouge à 660 nm lorsqu’elle est liée à l’ADN, avec une émission maximale à 682 nm, et est détectée à l’aide d’un filtre traditionnel rouge profond / Cy5. Il vous suffit dʼappliquer une goutte sur lʼéchantillon, dʼajouter une lamelle, de traiter et de prendre des images. ProLong Diamond est un milieu de monteur durcissant qui forme un parcours optique quasi-parfait (1,47 RI) et permet le stockage à plus long terme de l’échantillon, tout en le protégeant contre le photoblanchiment. Le monteur Diamond Prolong ne décolore pas ou ne rétrécit pas lorsqu'il est durci et stocké à long terme, ce qui permet de prendre des images fluorescentes de haute qualité semaines ou même des mois après le montage des lames.

Bénéficiez d’une protection par photoblanchiment sur l’ensemble des spectres visibles et IR
Aucune matière à utiliser pour les colorants fluorescents ou les protéines fluorescentes, le monteur ProLong Diamond vous aide à fournir une protection supérieure contre le photoblanchiment. Il affiche les meilleures performances de sa catégorie avec un vaste éventail de colorants fluorescents, notamment Alexa Fluor, FITC, TRTC, Texas Red, Cy3 et Cy5. Le monteur Diamond Prolong ne supprime pas les fluorophores et sa capacité à fournir un signal plus clair, sans fond, vous permet d’obtenir les images haute résolution de qualité supérieure pour la publication.

Signaux stables pendant l’imagerie et pour le stockage à long terme
Le monteur ProLong Diamond est l’option idéale pour l’archivage d’échantillons avec des colorants fluorescents ou des protéines fluorescentes. Il constitue également la solution idéale pour préserver lʼintensité du signal pendant les sessions dʼimagerie prolongées, par exemple lʼanalyse répétée dans des conditions dʼéclairage confocal à balayage laser, ou avec une microscopie super résolution. Il est facile à utiliser — Il vous suffit d’éliminer l’excédent d’eau de l’échantillon coloré et de le monter. Pour une visualisation immédiate de l’échantillon, choisissez notre monteur non durcissant, le monteur antifade diamant SlowFade.

Obtenez une excellente correspondance d’index de réfraction pour les images Crisp
Pour les applications d’imagerie haute résolution modernes, la comparaison d’index de réfraction (RI) est essentielle. Le milieu de montage ProLong Diamond durcit à un RI de 1,47. De plus, grâce à ses propriétés durcissantes, vous pouvez éviter les résines acryliques salissantes (par ex., vernis à ongles), qui peuvent endommager ou détruire les objectifs de microscope modernes en cas de contact.
Usage exclusivement réservé à la recherche. Ne pas utiliser pour des procédures de diagnostic.
Spécifications
DescriptionProLong™ Diamond Antifade Mountant, 1 x 10 mL
Quantité10 ml
Conditions d’expéditionHomologué pour des expéditions à température ambiante ou sur glace mouillée
Gamme de produitsProLong
Type de produitMilieu de montage anti-atténuation
Type de réactifSolution anti-atténuation
Volume (métrique)10 mL
Unit SizeEach
Contenu et stockage
Un flacon de 10 ml.
• Conservez à 2–8°C.
• Tenir à l’abri de la lumière.
•Stable pendant au moins 6 mois après réception.

Foire aux questions (FAQ)

What is the difference between ProLong and SlowFade antifade reagents?

Our ProLong antifade reagents dispense as a liquid that will solidify upon the evaporation of water. SlowFade antifade reagents remain liquid. If you are going to image right away and then dispose of your sample, you do not need a mountant that hardens, such as the SlowFade reagents. If you wish to archive your slide for more than a day, you will want a mounting medium that hardens (or “cures”). This hardening will limit the off-rates of various dye-conjugated antibodies and provides a better refractive index. Also, there will be a lower diffusion rate of free radicals, limiting photobleaching.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

If I use ProLong Gold Antifade Mountant to mount my slides, should I seal the edges?

ProLong Gold Antifade Mountant hardens overnight at room temperature. For short-term storage (a couple of weeks) you do not need to seal the edges of the coverslip, and the sample should be stable. Beyond that time, though, some dye conjugates will have an off-rate into the medium, so cold storage is recommended. Sealing the edges will prevent long-term discoloration (golden color) from developing around the edges of the coverslip as the anti-oxidants oxidize.

The edges may be sealed with melted paraffin, VALAP (1:1:1 vaseline, lanolin, paraffin) or epoxy glue. Nail polish is not recommended as various components of nail polish may diffuse into the mountant and quench fluorescent dyes.

Find additional tips, troubleshooting help, and resources within our Cell Imaging Support Center.

Some antifade mounting media stay as liquid whereas others harden. What is the benefit of having one that hardens?

If you are going to image right away and then dispose of your sample, you probably want a mountant that does not harden. If you wish to archive your slide for more than a day, you want a mountant that hardens (or "cures"). This hardening will slow or prevent off-rate of your dye or conjugate and often produces a better refractive index. Secondary sealing is usually not necessary. Also there will be lower diffusion of free radicals, thus limiting photobleaching.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

I mounted my cells in ProLong antifade mounting medium, but now I want to go back and re-label them. Is there a way I can unmount the coverslip after it has cured (hardened)?

Yes. Put the slide in a Coplin jar or beaker filled with warm (37oC) PBS buffer and let it sit, no agitation is required. The hardened ProLong mountant will swell and may slide off or be easily dislodged. If cells are adherent to the coverslip, make certain the coverslip side containing the cell or tissue sample does not land face down in the container or become scratched upon handling. Remove the coverslip, wash a couple of times, and proceed with re-staining and re-mounting in new ProLong mountant.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

I am using ProLong antifade mounting medium. Do I need to let it cure before imaging? Do I need to seal the edges of the coverslip?

You can image before it cures (hardens), and it will still slow photobleaching, but you have to let it cure overnight to get the best refractive index (resolution). There is no need to seal the edges. In fact, if you seal before it cures, it won't cure correctly. If you are archiving the slide for more than a month, though, seal the edges with resin, paraffin or VALAP (1:1:1 vaseline, lanolin, paraffin) after it cures or there may be slight discoloration along the edges over time.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

Citations et références (96)

Citations et références
Abstract
Intranasal administration of rotenone in mice attenuated olfactory functions through the lesion of dopaminergic neurons in the olfactory bulb.
Authors:Sasajima H, Miyazono S, Noguchi T, Kashiwayanagi M
Journal:
PubMed ID:26493152
'Many environmental chemicals are thought to affect brain function. It was reported that chemicals in the nasal cavity directly reach the brain through the connection between olfactory neurons and the olfactory bulb (OB). In this ''olfactory transport,'' xenobiotics absorbed at the nasal mucosa reach the brain by bypassing some physical ... More
Chemically Defined Culture and Cardiomyocyte Differentiation of Human Pluripotent Stem Cells.
Authors:Burridge PW, Holmström A, Wu JC
Journal:
PubMed ID:26439715
'Since the first discovery that human pluripotent stem cells (hPS cells) can differentiate to cardiomyocytes, efforts have been made to optimize the conditions under which this process occurs. One of the most effective methodologies to optimize this process is reductionist simplification of the medium formula, which eliminates complex animal-derived components ... More
Actin Cytoskeletal Organization in Drosophila Germline Ring Canals Depends on Kelch Function in a Cullin-RING E3 Ligase.
Authors:Hudson AM, Mannix KM, Cooley L
Journal:
PubMed ID:26384358
'The Drosophila Kelch protein is required to organize the ovarian ring canal cytoskeleton. Kelch binds and cross-links F-actin in vitro, and it also functions with Cullin 3 (Cul3) as a component of a ubiquitin E3 ligase. How these two activities contribute to cytoskeletal remodeling in vivo is not known. We ... More
Visualizing hypothalamic network dynamics for appetitive and consummatory behaviors.
Authors:Jennings JH, Ung RL, Resendez SL, Stamatakis AM, Taylor JG, Huang J, Veleta K, Kantak PA, Aita M, Shilling-Scrivo K, Ramakrishnan C, Deisseroth K, Otte S, Stuber GD
Journal:
PubMed ID:25635459
'Optimally orchestrating complex behavioral states, such as the pursuit and consumption of food, is critical for an organism''s survival. The lateral hypothalamus (LH) is a neuroanatomical region essential for appetitive and consummatory behaviors, but whether individual neurons within the LH differentially contribute to these interconnected processes is unknown. Here, we ... More
Rhinovirus Load Is High despite Preserved Interferon-ß Response in Cystic Fibrosis Bronchial Epithelial Cells.
Authors:Dauletbaev N, Das M, Cammisano M, Chen H, Singh S, Kooi C, Leigh R, Beaudoin T, Rousseau S, Lands LC
Journal:
PubMed ID:26599098
'Lung disease in cystic fibrosis (CF) is often exacerbated following acute upper respiratory tract infections caused by the human rhinovirus (HRV). Pathophysiology of these exacerbations is presently unclear and may involve deficient innate antiviral or exaggerated inflammatory responses in CF airway epithelial cells. Furthermore, responses of CF cells to HRV ... More