Safety-Guard Series II System
Safety-Guard Series II System
Thermo Scientific™

Safety-Guard Series II System

Thermo Scientific™ Safety-Guard Series II of radiation detection systems offer optimized protection against illicit trafficking of nuclear materials.
Have Questions?
Référence SGSII
Prix (EUR)
-
Demander un devis

Thermo Scientific™ Safety-Guard Series II of radiation detection systems offer optimized protection against illicit trafficking of nuclear materials. Offer significant gains in detection sensitivity for screening packages, people, or vehicles, for incident prevention and response.

Over 1400 systems installed worldwide at borders, seaports, couriers and government buildings.
  • Modular system components for maximum protection
  • Natural Background Reduction (NBR) technology
  • Large-area, premium-grade scintillation detectors
  • Protects: Courier services, Postal service, food storage/handling, facilities, transportation services
  • Optional neutron detectors enhance detection of Special Nuclear Materials (SNM)
  • Self-shielding algorithm
  • Enhanced neutron alarm
  • Sum channels
  • External modem support
  • Camera (optional)

Ordering Alerts:

Configurable system designed with our Technical Support to provide maximum protection and coverage

Recommended for:

  • Borders
  • Airports
  • Seaports
  • Government Buildings
  • Power Plants
  • Financial Institutions
  • Banks
  • Mints
  • Military Bases
  • Postal Services
  • Courier Services
  • Public Utilities
  • Embassies
Spécifications
AlarmesGamma Gross, NBR Cs-137, NBR Co-60, low-energy channel, Neutron (option)
Mémoire des donnéesData logging on hard drive
DescriptionContrôleur : série II
Surface de détectionapprox. 0.5 m² per panel
Type de détecteurPlastic Scintillation
Détecteursmax 8 modules either gamma or neutron
Type d’affichage17 in. TFT monitor (integrated 6.5 in. TFT optional)
Gamme d’énergielowest threshold approx. 30 keV (Gamma)
Taux d’erreur1:10000
Durée de mesure200 msec.
Alimentation électrique110 to 240 VAC, 50 to 65 Hz
Type de radiationGamma
Humidité relative10% to 90%, Non-Condensing
Sensibilitéapprox. 150000 cps/µSv/h per panel (Gamma)
Dimensions (impériale)Controller: 19.5 x 19 x 7 in.; 500G Plastic Detector: 2 x 5 x 48 in.; 1500G Plastic Detector: 2 x 5 x 48 in.; 500G Enclosure: 8 x 8 x 60 in.; 1500G Enclosure: 12 x 18 x 72 in.
Dimensions (métrique)Controller: 50 x 49.5 x 18 cm; 500G Plastic Detector: 5 x 12.5 x 122 cm; 1500G Plastic Detector: 5 x 38 x 122 cm; 500G Enclosure: 20.5 x 20.5 x 152 cm; 1500G Enclosure: 30.5 x 45.5 x 183 cm
Température (impériale) en fonctionnementPanels: -13°F to +122°F, Indoor equipment: 32°F to 104°F
Température (métrique) en fonctionnementPanels: -25°C to +50°C, Indoor equipment: 0°C to 40°C
Poids (impériale)500G detector: 200 lb.; 1500G Detector: 340 lb.
Volume de détection24 L
Interface utilisateurWindows 7
Poids (métrique)500G detector: 90.5 kg; 1500G Detector: 154 kg
Unit SizeEach