The Thermo Scientific QuantaRed Enhanced Chemifluorescent HRP Substrate (ADHP) is the most sensitive fluorescent ELISA substrate, providing sensitivity comparable to자세히 알아보기
Have Questions?
카탈로그 번호
수량
15159
110 ml
카탈로그 번호 15159
제품 가격(KRW)
662,000
Each
카트에 추가하기
수량:
110 ml
대량 주문 또는 맞춤형 요청
제품 가격(KRW)
662,000
Each
카트에 추가하기
The Thermo Scientific QuantaRed Enhanced Chemifluorescent HRP Substrate (ADHP) is the most sensitive fluorescent ELISA substrate, providing sensitivity comparable to enhanced chemiluminescence. This kit contains QuantaRed ADHP concentrate, QuantaRed Enhancer Solution, QuantaRed Stable Peroxide Solution, and QuantRed Stop Solution, and is sufficient for 960 wells (10 x 96-well plates at 100 μL working solution per well.
Features of the QuantaRed Enhanced Chemifluorescent HRP Substrate Kit:
• Sensitive—low picogram to femtogram detection • Red-Shifted - minimal autofluorescence interference from biological samples • Convenient—compatible with existing filter sets, no need to purchase special filter sets • Complete—mix and use reagents, no buffers to prepare or reagents to dissolve • Flexible—use Stop Solution to effectively stop the reaction resulting in stable signal for at least 4 hours or more. • Versatile—produces a strong colorimetric signal and can be read fluorescently or colorimetrically at 570nm
QuantaRed HRP Substrate enables high-yield and sensitive fluorescent and colorimetric detection of peroxidase activity in the ELISA format. QuantaRed Substrate uses a proprietary technology to increase fluorescent yield and sensitivity of the well-documented ADHP (10-Acetyl-3,7-dihydroxyphenoxazine) chemifluorescence reaction. ADHP is a non-fluorescent compound that reacts with horseradish peroxidase (HRP) to produce resorufin, a soluble, highly fluorescent reaction product with excitation/emission maxima of ∼570/585nm. The long wavelength emission of the resorufin minimizes interference from the low wavelength (blue and green) autofluorescence, making it an ideal substrate for quantitating target molecules in biological samples. In addition, the reaction product of QuantaRed Substrate is colorimetric as well as being fluorescent and can be read spectrophotmetrically at ∼570nm.
Specially formulated, QuantaRed Substrate incorporates chemical enhancers for maximum sensitivity and superior low end linearity. With high quantum yield and large extinction coefficient, QuantaRed Enhanced HRP Substrate has sensitivity comparable to enhanced chemiluminescence and is more sensitive than the Amplex Red substrates for the detection of HRP in ELISA applications.
For Research Use Only. Not for use in diagnostic procedures.
사양
검출 방법Fluorescence
제품라인QuantaRed
기질 특성Chemical Substrate
기질 유형HRP (Horseradish Peroxidase)
제품 유형ELISA Substrate
수량110 ml
Unit SizeEach
구성 및 보관
Sufficient For: 960 wells (10 x 96-well plates) at 100 μL working solution per well • QuantaRed ADHP Concentrate, 1 mL • QuantaRed Enhancer Solution, 50 mL • QuantaRed Stable Peroxide Solution, 50 mL • QuantaRed Stop Solution, 10 mL
Store at 4°C.
자주 묻는 질문(FAQ)
Can QuantaRed Enhanced Chemifluorescent HRP Substrate be used for Western blotting?.
No. This is a soluble HRP substrate for ELISA and other plate-based applications.
Can the QuantaRed Enhanced Chemifluorescent HRP Substrate signal be measured in a kinetic mode without stopping the reaction?
To measure in a kinetic mode, simply omit the Stop Solution. At high HRP concentrations and prolonged reaction times, the fluorescent product may self-quench, which is observed as continuous color development without a change in fluorescent intensity. Optimization of the detection antibody or HRP conjugate is required to determine the linear range of a particular assay system.
What types of plates are compatible with the QuantaRed Enhanced Chemifluorescent HRP Substrate?
Black opaque plates typically produce the best results. White opaque plates also can be used, but might produce higher backgrounds. A variety of other plate types, such as gray or opaque plates with transparent bottoms are also useful with this substrate. Use clear plates if the absorbance of the colored product will be measure instead of the fluorescence.