Spectra™ Multicolor High Range Protein Ladder
Spectra™ Multicolor High Range Protein Ladder
Thermo Scientific™

Spectra™ Multicolor High Range Protein Ladder

Thermo Scientific Spectra Multicolor High Range Protein Ladder is a mixture of eight blue-, green-, and orange-stained proteins (40 to자세히 알아보기
Have Questions?
보기 방식 변경buttonViewtableView
카탈로그 번호수량
266252 x 250 μL
26625X48 x 250 μL
카탈로그 번호 26625
제품 가격(KRW)
280,000
Online offer
Ends: 31-Dec-2025
311,000
할인액 31,000 (10%)
Each
카트에 추가하기
수량:
2 x 250 μL
대량 주문 또는 맞춤형 요청
제품 가격(KRW)
280,000
Online offer
Ends: 31-Dec-2025
311,000
할인액 31,000 (10%)
Each
카트에 추가하기
Thermo Scientific Spectra Multicolor High Range Protein Ladder is a mixture of eight blue-, green-, and orange-stained proteins (40 to 300 kDa) for use as size standards for high-MW proteins in gel electrophoresis and western blotting. The protein ladder is supplied in a ready-to-use format for direct loading onto gels; no need to heat, reduce, or add sample buffer prior to use.

Compare and view all other protein standards and ladders ›

Applications
• Monitoring of protein migration during SDS-PAGE
• Verifying western transfer efficiency
• Approximate sizing of proteins on SDS-polyacrylamide gels and western blots
• Locating a protein of interest for excision from an unstained preparative gel

For Research Use Only. Not for use in diagnostic procedures.
사양
검출 방법Colorimetric, NIR Fluorescence (700 nm), RGB Fluorescence (555 nm)
용도(애플리케이션)Tris-acetate gels
젤 호환성Bolt™ Bis-Tris Plus Gels, Novex™ Tricine Gels, Novex™ Tris-Glycine Gels, NuPAGE™ Bis-Tris Gels, NuPAGE™ Tris-Acetate Gels, SDS-PAGE Gels
분자량300, 250, 180, 130, 100, 70, 50, 40 kDa
제품라인Spectra
제품 유형Protein Ladder
수량2 x 250 μL
로드 준비Yes
권장 애플리케이션Tris-acetate gels
배송 조건Approved for shipment on Wet or Dry Ice
염색 유형3 colors: Blue, Orange, Green
시스템 유형Western Blotting, SDS-PAGE
Number of Markers8
크기 범위40 to 300 kDa
Unit SizeEach
구성 및 보관
Contents: two vials of 250 μL each

Storage buffer: 62.5 mM Tris-H3PO4 (pH 7.5 at 25°C), 1 mM EDTA, 2% SDS, 10 mM DTT, 1 mM NaN3 and 33% glycerol

Storage: Upon receipt store at -20°C

자주 묻는 질문(FAQ)

Why do Thermo Scientific prestained protein ladders not show the real protein sizes?

Coupling of chromophores to proteins affects the apparent molecular weight of proteins in SDS-PAGE relative to unstained standards. The apparent molecular weight of prestained protein standards is calibrated in the classical TRIS glycine-SDS Laemmli system, however prestained proteins may have different mobility in other electrophoresis buffer and gel systems. It should also be noted that the sizing of proteins by gel electrophoresis does not give an exact value and depends on the protein sequence and post-modification.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

The upper bands of the ladder are missing. What could be the reason?

The upper bands of the ladder may be degraded by proteases. Ladder, gel, buffer, pipettes, pipette tips, or equipment can be contaminated by proteases during usage. A general recommendation would be to avoid working with proteases in the same room. We would recommend preparing fresh solutions, cleaning the equipment, and using clean pipettes and tips. If the ladder itself is contaminated, please use a new tube of the ladder.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

Do the proteins in Thermo Scientific protein ladders have a His-Tag or would otherwise react with an anti-His-Tag antibody?

No, proteins in Thermo Scientific protein ladders are not His tagged. However, non-specific interaction between the ladder proteins and primary or secondary antibodies is possible and some His-Tag detection systems, such as Thermo Scientific 6xHis Protein Tag Stain Reagent Kit, show non-specific interaction. The protein ladder bands are more readily detected when using high antibody concentrations. The non-specific cross-reactivity is difficult to predict, it often has a different pattern dependent on the antibodies used in each individual experiment. The most general way to handle this problem would be to use lower concentrations of antibodies and to use lower amount of protein ladders. It may also be useful to leave one empty well between the ladder and the sample to overcome a possible leakage of the signal to the nearby sample lane.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

Can Thermo Scientific protein ladders be detected by Strep-Tactin conjugates?

PageRuler Unstained protein ladders can be detected directly on Western blots by using Strep-Tactin conjugates or an antibody against the Strep-tag II sequence. All PageRuler and Spectra ladder proteins contain an integral Strep-tag II sequence, however the prestained ladders cannot be detected by Strep-Tactin conjugates.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

Why are the PageRuler and Spectra ladder bands detected with antibodies against eukaryotic proteins?

All PageRuler and Spectra ladder bands are recombinant prokaryotic proteins purified from E. coli cells. None of them are related to eukaryotic proteins, however this cannot exclude the possibility that the ladder proteins may possess an epitope that is cross-reactive with the antibody used.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.