Triton™ Series Multicollector Thermal Ionization Mass Spectrometer

카탈로그 번호: IQLAAEGAASFAFYMAMV
Thermo Scientific™

Triton™ Series Multicollector Thermal Ionization Mass Spectrometer

카탈로그 번호: IQLAAEGAASFAFYMAMV

Extract high-precision isotope ratio information from your samples with the Thermo Scientific™ Triton™ Series Multicollector Thermal Ionization Mass Spectrometer (TIMS).

The Thermo Scientific™ Triton™ XT TIMS integrates the established field-proven technologies from the Triton Series instruments with the latest developments in technology for isotope ratio analysis from Thermo Fisher Scientific™.

 
카탈로그 번호
IQLAAEGAASFAFYMAMV
제품 사이즈
Each
설명
Triton Plus
포함
System only
제품 정가(KRW)
전체 사양
유형TIMS
설명Triton Plus
포함System only
Unit SizeEach
카탈로그 번호
제품 사이즈
Each
설명
Triton XT
포함
1013 Ω amplifier technology with gain calibration and tau correction, central dual-channel detector (SEM/Faraday cup).
제품 정가(KRW)
전체 사양
유형TIMS
설명Triton XT
포함1013 Ω amplifier technology with gain calibration and tau correction, central dual-channel detector (SEM/Faraday cup).
Unit SizeEach
2 / 2 표시
카탈로그 번호사양제품 사이즈설명포함제품 정가(KRW)
IQLAAEGAASFAFYMAMV전체 사양
EachTriton PlusSystem only견적 요청하기
유형TIMS
설명Triton Plus
포함System only
Unit SizeEach
0726203전체 사양
EachTriton XT1013 Ω amplifier technology with gain calibration and tau correction, central dual-channel detector (SEM/Faraday cup).견적 요청하기
유형TIMS
설명Triton XT
포함1013 Ω amplifier technology with gain calibration and tau correction, central dual-channel detector (SEM/Faraday cup).
Unit SizeEach
2 / 2 표시

The result of over two decades of development

The Thermo Scientific™ Triton XT™ TIMS is the pinnacle of over two decades of continuous development, combining outstanding technologies such as:

  • 1013Ω Amplifier Technology: extending the lower limits of the ultimate detector
  • Retarding Potential Quadrupole Lenses (RPQ): for the highest abundance sensitivity allowing high precision of extreme isotope ratios
  • Multi-ion counting (MIC) packages: dedicated for specific nuclear and geochronology applications
  • Stable and linear SEM and then CDD ion counters: for the smallest sample amounts and lowest abundance isotopes
  • High-performance Faraday cups: to guarantee uniform response and long lifetime
  • High stability thermal ionization source: characterized by a very small kinetic energy spread of the ions and optimized for maximum ion transmission for both single and double filament techniques
  • Reliable moveable collector array: brings up to 9 Faraday cups into precise alignment with ion beams of different dispersions. With a mass range to cover static Li measurements, that is extendable to cover static Ca
  • Virtual amplifier: allows cancellation of gain factor uncertainties through amplifier rotation, so that low ppm external reproducibility can be achieved using efficient static measurements