Orion Lab Star EC112 Conductivity Bench Meters
Orion Lab Star EC112 Conductivity Bench Meters
Orion Lab Star EC112 Conductivity Bench Meters
Orion Lab Star EC112 Conductivity Bench Meters
Orion Lab Star EC112 Conductivity Bench Meters
Thermo Scientific™

Orion Lab Star EC112 Conductivity Bench Meters

Orion Lab Star EC112 conductivity bench meters measure conductivity, salinity or TDS with temperature, feature a large backlit display for easy viewability, and offer small footprint to save bench space. This conductivity meter is ideal for simplified, budget-friendly lab testing and data recording.
Have Questions?
보기 방식 변경buttonViewtableView
카탈로그 번호유형
LSTAR1125Conductivity Meter Kit
LSTAR1120Conductivity Meter
카탈로그 번호 LSTAR1125
제품 가격(KRW)
1,955,000
Each
카트에 추가하기
유형:
Conductivity Meter Kit
제품 가격(KRW)
1,955,000
Each
카트에 추가하기
Measure conductivity, salinity or total dissolved solids with temperature using the Orion Lab Star EC112 conductivity bench meter. Featuring a large, backlit display for easy viewability and small footprint to save space, this meter is ideal for simplified, budget-friendly lab testing. Use the onscreen stabilizing and ready indicators to help identify when conductivity meter, salinity meter and TDS meter readings are complete. View active calibration logs with date and time, record key measurements using the 500-point data log with date and time, and output all logs to a printer or computer.

Orion Lab Star EC112 Conductivity Meter Features

  • Budget-friendly conductivity meter for simplified conductivity, salinity and TDS testing
  • Display shows conductivity, cell constant, temperature and temperature coefficient simultaneously for accurate data recording
  • Measure 0.00 μS to 500.0 mS conductivity, 0.00 to 80.0 ppt or 0.00 to 42.0 PSU salinity, 0.00 ppm to 500.0 ppt TDS and -5.0 to 105.0 °C or 23.0 to 221.0 °F to ensure comprehensive measurement capabilities
  • Perform one to five point conductivity and TDS calibrations, one point salinity calibrations and one point temperature adjustment calibrations for proficient SOP compliance
  • Large 5 inch backlit display makes viewing and recording measurements easy
  • Small meter footprint saves valuable bench space in your lab
  • Onscreen stabilizing and ready indicators help identify when readings are complete
  • Date and time data stamped data and calibration logs support GLP compliance
  • View active conductivity, salinity, TDS and temperature calibration logs with date and time stamp to ensure accurate, reproducible measurements
  • Use 500-point data log with date and time stamp to record key measurements
  • Output data and calibration logs to a printer or computer for long-term data storage

Meter and Meter Kits

  • LSTAR1120 is the conductivity meter and stand option, which allows you to purchase your conductivity electrode separately
  • LSTAR1125 is the standard conductivity meter kit option, for common conductivity samples in a wide range of 1 μS/cm to 20 mS/cm
사양
AC 어댑터Universal 100-240 V 50/60 Hz power supply with twist-and-lock meter connection and interchangeable wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets
정확도(전도도)±0.5 % of the reading ± 1 LSD
정확도(염도)±0.5 % of the reading ± 1 LSD
정확도(TDS)±0.5 % of the reading ± 1 LSD
정확도(온도)±0.3°C, ±0.5°F
알람 출력Calibration reminder alarm
백라이트 옵션Yes
보정Conductivity, salinity, TDS and temperature
보정 지점1 point salinity, 1-5 points TDS, 1 point temperature
보정 지점(전도도)1-5 points conductivity
세포 상수0.100 to 10.00 cm-1
인증/적합성CE, TUV 3-1, FCC Class A
함께 사용가능한 프로브2-cell and 4-cell conductivity electrodes
데이터 관리 세부 정보Continuous, Auto-Read and Timed read modes
설명Orion Lab Star EC112 conductivity/salinity/TDS bench meter standard kit
치수(길이 x 폭 x 높이)187.2 x 155.2 x 61.7 mm, 7.37 x 6.11 x 2.43 in.
용도(애플리케이션)For a Wide Variety of Conductivity Samples in The 1 μS/cm to 20 mS/cm Range
포함011050MD 2-cell K = 1.0 epoxy-body conductivity/ATC probe; 011007 1413 μS conductivity standard 5 x 60 mL; meter with electrode stand, PC cable, universal power adapter
입력8-pin MiniDIN for conductivity with built-in ATC
로그 기능 유형Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode
메모리Non-volatile
출력Computer or printer (STARA-106)
분해능(전도도)0.01, 0.1, 1 μS; 0.01, 0.1 mS
분해능(염도)0.01, 0.1 ppt; 0.01, 0.1 PSU
분해능(TDS)0.01, 0.1, 1 ppm; 0.01, 0.1 ppt
분해능(온도)0.1°C, 0.1°F
염도 측정 모드Natural Seawater (ppt) or Practical Salinity (PSU)
TDS 계수 범위0.40 to 1.00
온도 계수0 to 10 %/°C
온도 보상Linear (0 to 10 %/°C) or off
온도(미터법) 참조15.0, 20.0, 25.0 or 30.0°C
온도 프로브 보정1 point temperature offset calibration
온도 범위(영국식 단위)23.0°F to 221.0°F
온도 선택Manual or automatic with ATC temperature probe
유형Conductivity Meter Kit
워런티3 year meter warranty
중량(영국식 단위)1.54 lb.
중량(미터법)700 grams
데이터 포인트500 Sets with Date and Time Stamp
디스플레이 유형5 in. backlit LCD
IP 등급IP54
Measurement ModesConductivity with Temperature, Salinity with Temperature, TDS with Temperature
범위(전도도)0.00 μS to 500.0 mS
범위(염도)0.00 to 80.0 ppt; 0.00 to 42.0 PSU
온도 범위(미터법)-5.0°C to +105.0°C
Unit SizeEach

자주 묻는 질문(FAQ)

How long is the warranty period for Orion conductivity meters?

At Thermo Fisher Scientific, we stand behind the quality and reliability of our instruments. That's why we offer a minimum two-year (2) warranty on all Orion benchtop and portable conductivity meters. Obtain peace of mind knowing that your investment is protected. Should any issues arise within the warranty period, our team of experts is committed to providing you with prompt and efficient service. Be sure to check instrument specifications to confirm the warranty coverage period.

How do I perform a calibration using Orion conductivity meters?

Calibration is an important step to obtaining accurate results on your Orion benchtop or portable conductivity meter. Before beginning the calibration process, ensure that you are utilizing freshly poured, non-expired calibration standards to ensure accurate results. Follow the steps below to calibrate your conductivity meter.

• Prepare the calibration standards: Obtain at least one conductivity reference standard with a known conductivity value near the expected sample conductivity range. Ideally, use one standard close to the expected conductivity of your sample, and additional standards for different conductivity ranges. Ensure that the standards are fresh and have not expired.
• Clean the probe: Rinse the probe with distilled or deionized water to remove any debris or contaminants. If necessary, gently wipe the probe with a soft cloth or tissue.
• Turn on the conductivity meter: Power on the conductivity meter and allow it to warm up, if needed. • Immerse the probe: Immerse the probe into a beaker containing the first calibration standard. Ensure that the probe is fully submerged and that it is not touching the sides or bottom of the beaker.
• Allow stabilization: Allow the conductivity reading to stabilize. This may take a few moments, depending on the specific meter and standard being used. The reading should become steady and remain constant.
• Adjust the conductivity value: Using the calibration controls on the conductivity meter, adjust the reading to match the known conductivity value of the calibration standard. Reference the user manual for specific guidance on adjusting the conductivity.
• Rinse the probe: After calibration, rinse the probe with distilled or deionized water to remove any residual calibration solution.
• Repeat calibration: Repeat the calibration steps with the second calibration standard, following the same process as before.
• Verify accuracy: After calibration, it is recommended to check the conductivity meter's accuracy by measuring a conductivity solution of known value. This can help ensure the reliability of your measurements.

To learn more about conductivity calibration, maintenance and beyond, download our user guide: Orion Conductivity Probe User Guide

How do I perform an analysis using Orion conductivity meters?

Before beginning an analysis on your Orion benchtop or portable conductivity meter, assemble your materials. You will need a conductivity probe suitable for your application, calibration standards, and a test sample. Follow the steps below to obtain your conductivity analysis.

• Calibrate the conductivity meter: Start by calibrating your conductivity meter using at least one calibration standard. Typically, you will need at least one standard with a known conductivity value near the expected sample conductivity range. Be sure to reference the user manual for instructions on how to properly calibrate your conductivity meter.
• Prepare your sample: Ensure that your sample is at the desired temperature (most frequently room temperature).
• Immerse the electrode: Dip the conductivity probe into the sample. Avoid touching the sides or bottom of the container to prevent inaccurate readings.
• Allow for stabilization: Give the conductivity meter some time to stabilize and reach a steady reading. This may take a few seconds to a minute depending on your meter and the characteristics of the sample.
• Record the conductivity value: Once the conductivity meter stabilizes, record the conductivity value and temperature value displayed on the meter. Take note of any temperature compensation settings if applicable. • Rinse the probe: After each measurement, rinse the probe with distilled or deionized water to remove any residue or contaminants. This ensures accurate subsequent readings.
• Repeat (if necessary): If you need to analyze multiple samples, repeat the process with each sample, recalibrating the conductivity meter if required.

To learn more about how to get accurate conductivity measurements, download the smart note: Top 10 Mistakes to Avoid When Measuring Conductivity in Liquids.

How do I choose an Orion conductivity probe for my application?

When choosing an Orion conductivity probe for your application there are many factors to consider. Measurement range, sample type, container dimensions, accuracy/ precision requirements, temperature compensation needs, cell constant, durability, maintenance, and meter compatibility are all key features to evaluate.

To learn more about Orion conductivity probes, download the brochure: Orion Conductivity Probes

What supplies do I need to perform an analysis with Orion conductivity meters?

To perform an analysis using Orion benchtop and portable conductivity meters, you will need the following supplies: conductivity probe, conductivity standards, distilled or deionized water, sample containers, and a stirrer probe (optional).