Extract high-precision isotope ratio information from your samples with the Thermo Scientific™ Triton™ Series Multicollector Thermal Ionization Mass Spectrometer (TIMS).

The Thermo Scientific™ Triton™ XT TIMS integrates the established field-proven technologies from the Triton Series instruments with the latest developments in technology for isotope ratio analysis from Thermo Fisher Scientific™.

 
產品號碼
IQLAAEGAASFAFYMAMV
Unit Size
Each
Description
Triton Plus
Includes
System only
價格 (TWD)
完整規格
TypeTIMS
DescriptionTriton Plus
IncludesSystem only
Unit SizeEach
產品號碼
Unit Size
Each
Description
Triton XT
Includes
1013 Ω amplifier technology with gain calibration and tau correction, central dual-channel detector (SEM/Faraday cup).
價格 (TWD)
完整規格
TypeTIMS
DescriptionTriton XT
Includes1013 Ω amplifier technology with gain calibration and tau correction, central dual-channel detector (SEM/Faraday cup).
Unit SizeEach
顯示 2 項,共 2 項
產品號碼規格Unit SizeDescriptionIncludes價格 (TWD)
IQLAAEGAASFAFYMAMV完整規格
EachTriton PlusSystem only申請報價
TypeTIMS
DescriptionTriton Plus
IncludesSystem only
Unit SizeEach
0726203完整規格
EachTriton XT1013 Ω amplifier technology with gain calibration and tau correction, central dual-channel detector (SEM/Faraday cup).申請報價
TypeTIMS
DescriptionTriton XT
Includes1013 Ω amplifier technology with gain calibration and tau correction, central dual-channel detector (SEM/Faraday cup).
Unit SizeEach
顯示 2 項,共 2 項

The result of over two decades of development

The Thermo Scientific™ Triton XT™ TIMS is the pinnacle of over two decades of continuous development, combining outstanding technologies such as:

  • 1013Ω Amplifier Technology: extending the lower limits of the ultimate detector
  • Retarding Potential Quadrupole Lenses (RPQ): for the highest abundance sensitivity allowing high precision of extreme isotope ratios
  • Multi-ion counting (MIC) packages: dedicated for specific nuclear and geochronology applications
  • Stable and linear SEM and then CDD ion counters: for the smallest sample amounts and lowest abundance isotopes
  • High-performance Faraday cups: to guarantee uniform response and long lifetime
  • High stability thermal ionization source: characterized by a very small kinetic energy spread of the ions and optimized for maximum ion transmission for both single and double filament techniques
  • Reliable moveable collector array: brings up to 9 Faraday cups into precise alignment with ion beams of different dispersions. With a mass range to cover static Li measurements, that is extendable to cover static Ca
  • Virtual amplifier: allows cancellation of gain factor uncertainties through amplifier rotation, so that low ppm external reproducibility can be achieved using efficient static measurements