Shop All Cap Analog & Variants

Cap Analog (m7G(5')ppp(5')G), 10 A254 units (Invitrogen™)

Ambion® Cap Analog [m7G(5')ppp(5')G] is used for the synthesis of 5' capped RNA molecules in in vitro transcription reactions. These molecules are translated more efficiently in in vitro translation systems than uncapped mRNAs. 10 A254 U supplied. Substitution of cap analog for a portion of the GTP in an in vitro transcription reaction results in the incorporation of the cap structure into a corresponding fraction of the transcripts. Capped mRNAs are generally translated more efficiently in reticulocyte lysate and wheat germ in vitro translation systems. It is important that in vitro transcripts be capped for microinjection experiments because uncapped mRNAs are rapidly degraded. Cap analog is also used as a highly specific inhibitor of the initiation step of protein synthesis.

Quality Control:
Each Cap Analog is rigorously tested for contaminating nonspecific endonuclease, exonuclease, and RNase activity. Each is also assayed for the efficient synthesis of capped in vitro transcripts by using the cap analog in functional MEGAscript® In Vitro transcription and Retic Lysate translation reactions.

Accessory Products:
Complete kits are available with all the necessary reagents for the in vitro transcription of capped RNA transcripts. The mMESSAGE mMACHINE® T7 Ultra Kit includes ARCA (SKU #AM1345). Also available are kits containing conventional cap analog; mMESSAGE mMACHINE® T7 (SKU #AM1344), T3 (SKU #AM1348), and SP6 (SKU #AM1340) Kits. The Retic Lysate IVT™ (SKU #AM1200) for in vitro translation of mRNA is also available.

ARCA (Anti-Reverse Cap Analog) (Invitrogen™)

Ambion® Anti-Reverse Cap Analog (ARCA) is a cap analog used during in vitro transcription for the generation of capped transcripts. ARCA is modified in a way that ensures incorporation in the forward orientation only. Anti-Reverse Cap Analog (ARCA) is a modified cap analog in which the 3' OH group (closer to m7G) is replaced with –OCH3 (see schematic). Because of this substitution, the RNA polymerase can only initiate transcription with the remaining hydroxyl group thus forcing ARCA incorporation in the forward orientation. As a result, unlike transcripts synthesized with conventional cap analog, 100% of the transcripts synthesized with ARCA at the 5' end are translatable leading to a strong stimulatory effect on translation.

Quality Control:
Each Cap Analog is rigorously tested for contaminating nonspecific endonuclease, exonuclease, and RNase activity. Each is also assayed for the efficient synthesis of capped in vitro transcripts by using the cap analog in functional MEGAscript® In Vitro transcription and Retic Lysate translation reactions.

Accessory Products:
Complete kits are available with all the necessary reagents for the in vitro transcription of capped RNA transcripts. The mMESSAGE mMACHINE® T7 Ultra Kit includes ARCA (SKU #AM1345). Also available are kits containing conventional cap analog; mMESSAGE mMACHINE® T7 (SKU #AM1344), T3 (SKU #AM1348), and SP6 (SKU #AM1340) Kits. The Retic Lysate IVT™ (SKU #AM1200) for in vitro translation of mRNA is also available.

Cap Analog (m7G(5')ppp(5')G), 100 A254 Units (Invitrogen™)

Ambion® Cap Analog [m7G(5')ppp(5')G] is used for the synthesis of 5' capped RNA molecules in in vitro transcription reactions. These molecules are translated more efficiently in in vitro translation systems than uncapped mRNAs. 100 A254 U supplied. Substitution of cap analog for a portion of the GTP in an in vitro transcription reaction results in the incorporation of the cap structure into a corresponding fraction of the transcripts. Capped mRNAs are generally translated more efficiently in reticulocyte lysate and wheat germ in vitro translation systems. It is important that in vitro transcripts be capped for microinjection experiments because uncapped mRNAs are rapidly degraded. Cap analog is also used as a highly specific inhibitor of the initiation step of protein synthesis.

Quality Control:
Each Cap Analog is rigorously tested for contaminating nonspecific endonuclease, exonuclease, and RNase activity. Each is also assayed for the efficient synthesis of capped in vitro transcripts by using the cap analog in functional MEGAscript® In Vitro transcription and Retic Lysate translation reactions.

Accessory Products:
Complete kits are available with all the necessary reagents for the in vitro transcription of capped RNA transcripts. The mMESSAGE mMACHINE® T7 Ultra Kit includes ARCA (SKU #AM1345). Also available are kits containing conventional cap analog; mMESSAGE mMACHINE® T7 (SKU #AM1344), T3 (SKU #AM1348), and SP6 (SKU #AM1340) Kits. The Retic Lysate IVT™ (SKU #AM1200) for in vitro translation of mRNA is also available.

Cap Analog (m7G(5')ppp(5')G), 25 A254 Units (Invitrogen™)

Ambion® Cap Analog [m7G(5')ppp(5')G] is used for the synthesis of 5' capped RNA molecules in in vitro transcription reactions. These molecules are translated more efficiently in in vitro translation systems than uncapped mRNAs. 25 A254 U supplied. Substitution of cap analog for a portion of the GTP in an in vitro transcription reaction results in the incorporation of the cap structure into a corresponding fraction of the transcripts. Capped mRNAs are generally translated more efficiently in reticulocyte lysate and wheat germ in vitro translation systems. It is important that in vitro transcripts be capped for microinjection experiments because uncapped mRNAs are rapidly degraded. Cap analog is also used as a highly specific inhibitor of the initiation step of protein synthesis.

Quality Control:
Each Cap Analog is rigorously tested for contaminating nonspecific endonuclease, exonuclease, and RNase activity. Each is also assayed for the efficient synthesis of capped in vitro transcripts by using the cap analog in functional MEGAscript® In Vitro transcription and Retic Lysate translation reactions.

Accessory Products:
Complete kits are available with all the necessary reagents for the in vitro transcription of capped RNA transcripts. The mMESSAGE mMACHINE® T7 Ultra Kit includes ARCA (SKU #AM1345). Also available are kits containing conventional cap analog; mMESSAGE mMACHINE® T7 (SKU #AM1344), T3 (SKU #AM1348), and SP6 (SKU #AM1340) Kits. The Retic Lysate IVT™ (SKU #AM1200) for in vitro translation of mRNA is also available.