Accelerating ScienceAnalyteGuru / Gas Chromatography / Helium Shortage and Price Spikes: Which is More Concerning?

Helium Shortage and Price Spikes: Which is More Concerning?

By Dr. Daniela Cavagnino, Product Marketing Manager, GC/Autosampler, Thermo Fisher Scientific 02.01.2023

The uncertainty in the market around the helium shortage continues. Industries, hospitals and scientific laboratories relying on helium gas are experiencing — since mid-2021 — the fourth wave of the shortage. Helium Shortage 4.0, as experts refer to it, is expected to continue into 2023 [1].

Gas chromatography contributes, in a very small part, to global helium consumption, but analytical testing laboratories who need to maintain helium as a GC carrier gas risk facing a severe impact from the recurring gas shortage. Service suppliers, along with contract testing and manufacturing QA/QC labs, need to ensure they can provide analytical data as quickly as possible. Delayed delivery is disruptive for their business and much more of a concern compared to price increases.

In previous blogs posts [2,3] I wrote about the opportunity to significantly reduce helium gas consumption when running a Thermo Scientific GC or GC-MS system, thanks to the advanced technology of the Thermo Scientific™ HeSaver-H2Safer™ option for split/ splitless (SSL) injector, available on the Thermo Scientific™ TRACE™ 1600 Series GC.

What about the customer experience?

Whenever migrating to a different carrier gas (e.g., hydrogen or nitrogen) is not a feasible choice, due to unacceptable impact on analytical performance and data quality, reducing helium gas consumption is a viable solution to mitigate delayed delivery and avoid downtime.

This is the case of NOW Foods quality control laboratory in Bloomingdale, Ill., USA, serving their manufacturing facility with about 15,000 individual tests per month. They are using multiple grades of helium, depending on the application, being pretty tight with supply. Within the contaminants testing, they are using the Thermo Scientific™ TSQ™ 9610 GC-MS/MS for the analysis of trace level of pesticide residues and cannot accept any compromise on sensitivity, unavoidable if using a different carrier gas.

“… If we need to sacrifice our sensitivity level, that’s something that’s going to be very difficult for us to absorb and still be able to feel confident in putting out quality data. … with the implementation of the Thermo Scientific Helium Saver we aim to conserve Helium and minimize potential instrument downtime, without affecting the results, … not running out of the helium that we have, is priceless because that allows us to keep going with our operations and keeping the rest of the manufacturing facility going.”

— Jonathan De Cenzi, Laboratory Manager at NOW Foods

Video: How HeSaver is helping NOW Foods conserve their helium

View the entire interview with the NOW Foods laboratory staff as they share how smoothly they implemented the HeSaver technology on their TSQ 9610 GC-MS/MS.

HeSaver-H2Safer implementation does not require changes in method settings and will not impact the analytical performance of the GC system, while offering significant gas savings and extended cylinder lifetime. Comparative data with standard SSL injector are available for most common GC applications (e.g., PCBs, PAHs, dioxins, nitrosamines), showing equivalent results and method robustness.

The following application notes demonstrate data quality and helium gas saving capability for common GC-MS applications:

  • SL001585 – Carrier gas conservation for nitrosamines analysis in pharmaceutical products
  • SL001569 – Reducing the helium consumption without compromising performance using the HeSaver-H2 Saf…
  • SL001606 – Polyaromatic hydrocarbon analysis by gas chromatography mass spectrometry using HeSaver-H…
  • AN001594 – Uncompromised sensitivity in polychlorinated dibenzo-p-dioxins/furans analysis using trip…

Additional resources

  • Video – A better way to manage gas consumption with the HeSaver-H2Safer technology
  • TN001218 – Addressing gas conservation challenges when using helium or hydrogen as GC carrier gas
  • Helium Saver Calculator | Thermo Fisher Scientific – IT

References

[1] Global helium shortage continues to impact many industries | CTV News

[2] AnalyteGuru – What good is Conserving Helium Carrier Gas only when your GC System is Idle?

[3] AnalyteGuru – Moving to Hydrogen or Staying with Helium? A solution to support both choices

Fairy light background image

When “Fairy Lights” Turn Toxic: The Hidden Hazard of Chlorinated Paraffins

Are you looking forward to the holidays and a lot of cozy ev...

Read More

Stay Ahead in Developing Green Energy Solutions with FAME Analysis for Jet Fuel

Biofuels, particularly biodiesel, are an attractive, cleaner...

Read More

Beyond IP 585: A Faster, More Precise Approach to Aviation Fuel FAME Analysis

As the aviation industry continues to evolve toward greener ...

Read More
Pesticides

Pesticide Residue Analysis in the 21st Century: Innovations in Sample Preparation and Detection Using the Thermo Scientific TSQ 9610 GC-MS/MS

Introduction The accurate detection of pesticide residues in...

Read More

Dr. Daniela Cavagnino

Dr. Daniela Cavagnino is Product Marketing Manager for GC and Sampling Solutions. She started her career in gas chromatography at Thermo Fisher Scientific spending several years in the R&D laboratories working on GC technology innovation. Then, she conveyed her technical background into product management and marketing management roles with more than 20 years’ experience in promoting GC/GCMS technology and applications in several different market segments.
Oligonucleotide Therapeutics: A Biopharmaceutical Basics Overview
Overcoming ‘Photobombing’ from Background Ions

Privacy StatementTerms & ConditionsLocationsSitemap

© 2025 Thermo Fisher Scientific. All Rights Reserved.

Talk to us