Thermo Scientific™

Multiskan™ FC Microplate Photometer

Catalog number: 51119100
Thermo Scientific™

Multiskan™ FC Microplate Photometer

Catalog number: 51119100
Multiskan FC brings together over 40 years experience of the well-known Multiskan product brand, with features for enhanced usability. The Multiskan FC has a 340–850 nm wavelength range, enabling a wide variety of applications from enzyme kinetic studies to Lowry assays. The instrument provides fast and accurate measurements enabling complete 96-well plate reading in less than seven seconds. The instrument is also equipped with linear shaking as standard. A model with an incubator enables incubation temperatures up to 50°C and the capacity to read 384-well plates. SkanIt software supports optimal use of the instrument with a visual workflow, effortless data analysis and exporting capabilities.
 
Catalog Number
51119100
Unit Size
Each
Description
Multiskan FC with incubator
Plate Type
96 and 384-well Plates
Price (TWD)
Full specifications
Quantity
-
CompatibilityRobot
Detector TypePhotodetector
Incubator TemperatureAmbient +4°C to 50°C
InterfaceOn-board or PC Control
Light SourceQuartz Halogen Lamp
Measurement Speed7 s for 96-well Plate (Fast Mode), 13 s for 96-well Plate (Normal Mode)
Measurement TechnologyAbsorbance
Plate Type96 and 384-well Plates
Product LineMultiskan
ShakingLinear
Software TypeSkanIt Software
Wavelength SelectionFilters
Accuracy± 1% (0 to 3 Abs) or ± 0.003 Abs, which ever is greater at 405 nm
Depth (English)15.7 in.
Depth (Metric)40 cm
DescriptionMultiskan FC with incubator
Filters8-position filter wheel; filters installed: 405nm, 450nm, and 620nm
Height (English)8.7 in.
Height (Metric)22 cm
Hertz50/60 Hz
Linearity96-well plate: 0 to 3 Abs, ±2% at 405 nm
384-well plate: 0 to 2.5 Abs, ±2% at 405 nm
PrecisionCV ≤ 0.2% (0.3 to 3 Abs) at 405 nm
Resolution0.001 Abs
Voltage100/240 V
Warranty1 Year
Wavelength Range340 to 850 nm
Width (English)11.4 in.
Width (Metric)29 cm
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Multiskan FC
Plate Type
96-well Plate
Price (TWD)
Full specifications
Quantity
-
CompatibilityRobot
Detector TypePhotodetector
InterfaceOn-board or PC Control
Light SourceQuartz Halogen Lamp
Measurement Speed7 s for 96-well Plate (Fast Mode), 13 s for 96-well Plate (Normal Mode)
Measurement TechnologyAbsorbance
Plate Type96-well Plate
Product LineMultiskan
ShakingLinear
Software TypeSkanIt Software
Wavelength SelectionFilters
Accuracy± 1% (0 to 3 Abs) or ± 0.003 Abs, which ever is greater at 405 nm
Depth (English)15.7 in.
Depth (Metric)40 cm
DescriptionMultiskan FC
Filters8-position filter wheel; filters installed: 405nm, 450nm, and 620nm
Height (English)8.7 in.
Height (Metric)22 cm
Hertz50/60 Hz
Linearity0 to 3 Abs, ±2% at 405 nm, 96-well plate
PrecisionCV ≤ 0.2% (0.3 to 3 Abs) at 405 nm
Resolution0.001 Abs
Voltage100/240 V
Warranty1 Year
Wavelength Range340 to 850 nm
Width (English)11.4 in.
Width (Metric)29 cm
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Accessory - Lamp 6V/10W
Plate Type
Price (TWD)
***
Full specifications
Quantity
Light Source10W Lamp
Product LineMultiskan
DescriptionAccessory - Lamp 6V/10W
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Multiskan FC (Japan)
Plate Type
96-well Plates
Price (TWD)
Full specifications
Quantity
-
CompatibilityRobot
CuvettesNo
Dimensions (L x W x H)400 x 290 x 220 mm (15.7 x 11.4 x 8.7 in.)
Incubator Temperature50°C
InterfaceUSB for computer connections, data export, and external printer
Measurement TechnologyAbsorbance
Plate Type96-well Plates
Product LineMultiskan
ShakingNone
Software TypeSkanIt Software
Wavelength SelectionFilters
Accuracy (Photometric)± 1% (0 to 3 Abs)or ±0.003 Abs, 450 nm
Depth (Metric)400 mm
DescriptionMultiskan FC (Japan)
For Use With (Application)ELISA, enzyme activity, protein quantification, endotoxin, cytotoxicity and proliferation assays, enzyme assays and growth curves
Height (Metric)220 mm
IncludesSkanIt software, Reserach Edition
Linearity0 to 3 Abs, ±2% at 450 nm
PrecisionCV ±0.2% (0.3 to 3 Abs), 450 nm
Software Language VersionsEnglish, German, French, Spanish, Portuguese, Russian, Chinese, Japanese
Warranty1 Year
Wavelength Range340 to 850 nm
Weight (Metric)8.5 kg
Width (Metric)290 mm
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Multiskan FC with Incubator (Japan)
Plate Type
96 and 384-well Plates
Price (TWD)
Full specifications
Quantity
-
CompatibilityRobot
CuvettesNo
Dimensions (L x W x H)400 x 290 x 220 mm (15.7 x 11.4 x 8.7 in.)
Incubator TemperatureAmbient + 4°C to 50°C
InterfaceUSB for computer connections, data export, and external printer
Measurement Speed96 wells: 7 sec., 384 wells: 13 sec.
Measurement TechnologyAbsorbance
Plate Type96 and 384-well Plates
Product LineMultiskan
ShakingLinear
Software TypeSkanIt Software
Accuracy (Photometric)± 1% (0 to 3 Abs)or ±0.003 Abs, 450 nm
Depth (Metric)400 mm
DescriptionMultiskan FC with Incubator (Japan)
For Use With (Application)ELISA, enzyme activity, protein quantification, endotoxin, cytotoxicity and proliferation assays, enzyme assays and growth curves
Height (Metric)220 mm
IncludesSkanIt software, Reserach Edition
Linearity0 to 3 Abs, ±2% at 450 nm
PrecisionCV ±0.2% (0.3 to 3 Abs), 450 nm
Software Language VersionsEnglish, German, French, Spanish, Portuguese, Russian, Chinese, Japanese
Warranty1 Year
Wavelength Range340 to 850 nm
Weight (Metric)8.5 kg
Width (Metric)290 mm
Unit SizeEach
Showing 5 of 5
Catalog NumberSpecificationsUnit SizeDescriptionPlate TypePrice (TWD)Quantity
51119100Full specifications
EachMultiskan FC with incubator96 and 384-well PlatesRequest A Quote-
CompatibilityRobot
Detector TypePhotodetector
Incubator TemperatureAmbient +4°C to 50°C
InterfaceOn-board or PC Control
Light SourceQuartz Halogen Lamp
Measurement Speed7 s for 96-well Plate (Fast Mode), 13 s for 96-well Plate (Normal Mode)
Measurement TechnologyAbsorbance
Plate Type96 and 384-well Plates
Product LineMultiskan
ShakingLinear
Software TypeSkanIt Software
Wavelength SelectionFilters
Accuracy± 1% (0 to 3 Abs) or ± 0.003 Abs, which ever is greater at 405 nm
Depth (English)15.7 in.
Depth (Metric)40 cm
DescriptionMultiskan FC with incubator
Filters8-position filter wheel; filters installed: 405nm, 450nm, and 620nm
Height (English)8.7 in.
Height (Metric)22 cm
Hertz50/60 Hz
Linearity96-well plate: 0 to 3 Abs, ±2% at 405 nm
384-well plate: 0 to 2.5 Abs, ±2% at 405 nm
PrecisionCV ≤ 0.2% (0.3 to 3 Abs) at 405 nm
Resolution0.001 Abs
Voltage100/240 V
Warranty1 Year
Wavelength Range340 to 850 nm
Width (English)11.4 in.
Width (Metric)29 cm
Unit SizeEach
51119000Full specifications
EachMultiskan FC96-well PlateRequest A Quote-
CompatibilityRobot
Detector TypePhotodetector
InterfaceOn-board or PC Control
Light SourceQuartz Halogen Lamp
Measurement Speed7 s for 96-well Plate (Fast Mode), 13 s for 96-well Plate (Normal Mode)
Measurement TechnologyAbsorbance
Plate Type96-well Plate
Product LineMultiskan
ShakingLinear
Software TypeSkanIt Software
Wavelength SelectionFilters
Accuracy± 1% (0 to 3 Abs) or ± 0.003 Abs, which ever is greater at 405 nm
Depth (English)15.7 in.
Depth (Metric)40 cm
DescriptionMultiskan FC
Filters8-position filter wheel; filters installed: 405nm, 450nm, and 620nm
Height (English)8.7 in.
Height (Metric)22 cm
Hertz50/60 Hz
Linearity0 to 3 Abs, ±2% at 405 nm, 96-well plate
PrecisionCV ≤ 0.2% (0.3 to 3 Abs) at 405 nm
Resolution0.001 Abs
Voltage100/240 V
Warranty1 Year
Wavelength Range340 to 850 nm
Width (English)11.4 in.
Width (Metric)29 cm
Unit SizeEach
1410101Full specifications
EachAccessory - Lamp 6V/10W***
Light Source10W Lamp
Product LineMultiskan
DescriptionAccessory - Lamp 6V/10W
Unit SizeEach
51119050Full specifications
EachMultiskan FC (Japan)96-well PlatesRequest A Quote-
CompatibilityRobot
CuvettesNo
Dimensions (L x W x H)400 x 290 x 220 mm (15.7 x 11.4 x 8.7 in.)
Incubator Temperature50°C
InterfaceUSB for computer connections, data export, and external printer
Measurement TechnologyAbsorbance
Plate Type96-well Plates
Product LineMultiskan
ShakingNone
Software TypeSkanIt Software
Wavelength SelectionFilters
Accuracy (Photometric)± 1% (0 to 3 Abs)or ±0.003 Abs, 450 nm
Depth (Metric)400 mm
DescriptionMultiskan FC (Japan)
For Use With (Application)ELISA, enzyme activity, protein quantification, endotoxin, cytotoxicity and proliferation assays, enzyme assays and growth curves
Height (Metric)220 mm
IncludesSkanIt software, Reserach Edition
Linearity0 to 3 Abs, ±2% at 450 nm
PrecisionCV ±0.2% (0.3 to 3 Abs), 450 nm
Software Language VersionsEnglish, German, French, Spanish, Portuguese, Russian, Chinese, Japanese
Warranty1 Year
Wavelength Range340 to 850 nm
Weight (Metric)8.5 kg
Width (Metric)290 mm
Unit SizeEach
51119150Full specifications
EachMultiskan FC with Incubator (Japan)96 and 384-well PlatesRequest A Quote-
CompatibilityRobot
CuvettesNo
Dimensions (L x W x H)400 x 290 x 220 mm (15.7 x 11.4 x 8.7 in.)
Incubator TemperatureAmbient + 4°C to 50°C
InterfaceUSB for computer connections, data export, and external printer
Measurement Speed96 wells: 7 sec., 384 wells: 13 sec.
Measurement TechnologyAbsorbance
Plate Type96 and 384-well Plates
Product LineMultiskan
ShakingLinear
Software TypeSkanIt Software
Accuracy (Photometric)± 1% (0 to 3 Abs)or ±0.003 Abs, 450 nm
Depth (Metric)400 mm
DescriptionMultiskan FC with Incubator (Japan)
For Use With (Application)ELISA, enzyme activity, protein quantification, endotoxin, cytotoxicity and proliferation assays, enzyme assays and growth curves
Height (Metric)220 mm
IncludesSkanIt software, Reserach Edition
Linearity0 to 3 Abs, ±2% at 450 nm
PrecisionCV ±0.2% (0.3 to 3 Abs), 450 nm
Software Language VersionsEnglish, German, French, Spanish, Portuguese, Russian, Chinese, Japanese
Warranty1 Year
Wavelength Range340 to 850 nm
Weight (Metric)8.5 kg
Width (Metric)290 mm
Unit SizeEach
Showing 5 of 5
  • Proven performance and reliable day-to-day results through patented optical design and in-built self-diagnostics
  • A broad wavelength range of 340–850 nm for a wide variety of research and routine applications such as ELISA immunoassays, protein quantification, endotoxin, cytotoxicity and proliferation assays, enzyme assays and growth curves
  • Equipped with an eight-position filter wheel with three standard filters, 405 nm, 450 nm and 620 nm, preinstalled
  • A comprehensive range of easy-to install additional filters available for order
  • Fast and accurate measurement of both 96- and 384-well plates for various throughput requirements
  • Shaking and incubation up to 50°C for temperature critical assays
  • Ease of use through the large color screen and a variety of language versions
  • Visual and logical SkanIt software for comprehensive instrument control and data handling
  • Multiskan verification plate available for instrument performance verification
  • Robot compatibility for high-throughput environments
Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References

    Search citations by name, author, journal title or abstract text