Get high accuracy, premium performance and ultimate flexibility with the Thermo Scientific™ Orion™ Versa Star Pro™ pH/LogR™ Benchtop Meter. Meet your most challenging applications for pH, mV, ORP and LogR temperature. Easily view measurements on the stunning color display and customize the four meter channels with interchangeable modules. Use LogR technology to measure both pH and temperature using the glass-bulb of most pH electrodes. Log up to 2000 data point sets with time/date stamp and easily transfer calibration and data logs via USB or RS232 to a printer or computer.
AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR) |
Alarm Output | Set point alarm, high/low limit alarm, calibration due alarm |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Channels | 4 - customizable with modules |
Description | Orion Versa Star Pro pH/LogR benchtop meter with stand |
Accuracy (mV) | ±0.2 or ±0.05%, whichever is greater |
Accuracy (pH) | ±0.002 |
Accuracy (Temperature) | ±0.1°C |
Backlight Option | Yes |
Calibration | pH with calibration editing option, relative mV, ORP, LogR temperature and temperature |
Calibration Points | 1 to 6 |
Data Management Details | Transfer single, range or all data points to printer or computer |
Data Points | 2000 with Date and Time Stamp |
Display Type | LCD, Color Graphic with User-Customizable Options |
Log Function Type | Automatic with Auto-Read, Timed and Single Shot Measure Modes; Manual |
Measurement Modes | pH with LogR temperature, mV, relative mV or ORP with temperature |
Outputs | USB, RS-232 |
Range (mV) | ±2000.0 |
Range (pH) | -2 to 20 |
Resolution (pH) | 0.001, 0.01, 0.1 |
Temperature Range (Metric) | -5°C to +105°C |
Includes | Versa Star Pro meter with pH/LogR module, electrode stand, 100-240V universal power adapter, computer cable |
Inputs | BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), two stirrer inputs (stirrer probe) |
IP Rating | IP-54 |
Isopotential Point | 7.000pH (adjustable) |
Keypad | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
Languages | English, Spanish, French, Italian, German, Chinese, Portuguese and Korean |
Memory | Non-volatile memory preserves data log, calibration log and meter settings |
Methods | 10 per channel |
Power Rating | DC input: 9VDC, 1A |
Power Supply | Universal AC adapter (included) |
Probe Type | pH electrode, ORP electrode, reference half-cell electrode, ATC temperature probe, stirrer probe (purchase separately) |
Range (ORP) | ±2000.0mV |
Range (Relative mV) | ±2000.0mV |
Relative Humidity Range | 5 to 85%, non-condensing |
Resolution (mV) | 0.1mV |
Resolution (Temperature) | 0.1°C, 0.1°F |
Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
Temperature (English) Operating | 41°F to 113°F (ambient) |
Temperature (Metric) Operating | 5°C to 45°C (ambient) |
Temperature Probe Calibration | 1 point temperature offset calibration, 3 point LogR temperature calibration |
Temperature Range (English) | 22.0°F to 221.0°F |
Temperature Selection | Manual or automatic with ATC temperature probe, automatic with pH electrode using LogR mode |
Warranty | 3 Year Meter and Module Warranty |
Dimensions (L x W x H) | 28 cm x 24 cm x 10 cm (11 in. x 9.5 in. x 3.9 in.), modules add ≤ 2 cm (0.8 in.) L & H |
Weight (English) | 2.5 lb., modules add 0.5 lb. each |
Weight (Metric) | 1.2 kg, modules add 0.2 kg each |
Unit Size | Each |
AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR) |
Alarm Output | Set point alarm, high/low limit alarm, calibration due alarm |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Channels | 4 - customizable with modules |
Description | Orion Versa Star Pro pH/LogR benchtop meter difficult sample kit with ROSS Sure-Flow pH electrode and ATC probe |
Accuracy (mV) | ±0.2 or ±0.05%, whichever is greater |
Accuracy (pH) | ±0.002 |
Accuracy (Temperature) | ±0.1°C |
Backlight Option | Yes |
Calibration | pH with calibration editing option, relative mV, ORP, LogR temperature and temperature |
Calibration Points | 1 to 6 |
Data Management Details | Transfer single, range or all data points to printer or computer |
Data Points | 2000 with Date and Time Stamp |
Display Type | LCD, Color Graphic with User-Customizable Options |
Log Function Type | Automatic with Auto-Read, Timed and Single Shot Measure Modes; Manual |
Measurement Modes | pH with LogR temperature, mV, relative mV or ORP with temperature |
Outputs | USB, RS-232 |
Range (mV) | ±2000.0 |
Range (pH) | -2 to 20 |
Resolution (pH) | 0.001, 0.01, 0.1 |
Temperature Range (Metric) | -5°C to +105°C |
Includes | Versa Star Pro meter with pH/LogR module, 8172BNWP ROSS Sure-Flow glass-body pH electrode, 927007MD stainless steel ATC probe, 810199 pH buffer kit, 810007 ROSS fill solution, electrode stand, 100-240V universal power adapter, computer cable |
Inputs | BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), two stirrer inputs (stirrer probe) |
IP Rating | IP-54 |
Isopotential Point | 7.000pH (adjustable) |
Keypad | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
Languages | English, Spanish, French, Italian, German, Chinese, Portuguese and Korean |
Memory | Non-volatile memory preserves data log, calibration log and meter settings |
Methods | 10 per channel |
Model | Orion Versa Star Pro 80 pH/LogR/mV/RmV/ORP/Temperature Benchtop Meter |
Power Rating | DC input: 9VDC, 1A |
Power Supply | Universal AC adapter (included) |
Probe Type | pH electrode, ORP electrode, reference half-cell electrode, ATC temperature probe, stirrer probe |
Range (ORP) | ±2000.0mV |
Range (Relative mV) | ±2000.0mV |
Relative Humidity Range | 5 to 85%, non-condensing |
Resolution (mV) | 0.1mV |
Resolution (Temperature) | 0.1°C, 0.1°F |
Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
Temperature (English) Operating | 41°F to 113°F (ambient) |
Temperature (Metric) Operating | 5°C to 45°C (ambient) |
Temperature Probe Calibration | 1 point temperature offset calibration, 3 point LogR temperature calibration |
Temperature Range (English) | 22.0°F to 221.0°F |
Temperature Selection | Manual or automatic with ATC temperature probe, automatic with pH electrode using LogR mode |
Warranty | 3 Year Meter and Module Warranty |
Dimensions (L x W x H) | 28 cm x 24 cm x 10 cm (11 in. x 9.5 in. x 3.9 in.), modules add ≤ 2 cm (0.8 in.) L & H |
Weight (English) | 2.5 lb., modules add 0.5 lb. each |
Weight (Metric) | 1.2 kg, modules add 0.2 kg each |
Unit Size | Each |
AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR) |
Alarm Output | Set point alarm, high/low limit alarm, calibration due alarm |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Channels | 4 - customizable with modules |
Description | Orion Versa Star Pro pH/LogR benchtop meter micro sample kit with TRIS-compatible ROSS micro pH electrode and ATC probe |
Accuracy (mV) | ±0.2 or ±0.05%, whichever is greater |
Accuracy (pH) | ±0.002 |
Accuracy (Temperature) | ±0.1°C |
Backlight Option | Yes |
Calibration | pH with calibration editing option, relative mV, ORP, LogR temperature and temperature |
Calibration Points | 1 (relative mV), 1 (ORP) |
Data Management Details | Transfer single, range or all data points to printer or computer |
Data Points | 2000 with Date and Time Stamp |
Display Type | LCD, Color Graphic with User-Customizable Options |
Log Function Type | Automatic with Auto-Read, Timed and Single Shot Measure Modes; Manual |
Measurement Modes | pH with LogR temperature, mV, relative mV or ORP with temperature |
Outputs | USB, RS-232 |
Range (mV) | ±2000 |
Range (pH) | -2 to 20 |
Resolution (pH) | 0.001, 0.01, 0.1 |
Temperature Range (Metric) | -5°C to +105°C |
Includes | Versa Star Pro meter with pH/LogR module, 8220BNWP ROSS Micro glass-body pH electrode, 927007MD stainless steel ATC probe, 810199 pH buffer kit, electrode stand, 100-240V universal power adapter, computer cable |
Inputs | BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), two stirrer inputs (stirrer probe) |
IP Rating | IP-54 |
Isopotential Point | 7.000pH (adjustable) |
Keypad | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
Languages | English, Spanish, French, Italian, German, Chinese, Portuguese and Korean |
Memory | Non-volatile memory preserves data log, calibration log and meter settings |
Methods | 10 per channel |
Power Rating | DC input: 9VDC, 1A |
Power Supply | Universal AC adapter (included) |
Probe Type | pH electrode, ORP electrode, reference half-cell electrode, ATC temperature probe, stirrer probe |
Range (ORP) | ±2000.0mV |
Range (Relative mV) | ±2000.0mV |
Relative Humidity Range | 5 to 85%, non-condensing |
Resolution (mV) | 0.1mV |
Resolution (Temperature) | 0.1°C, 0.1°F |
Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
Temperature (English) Operating | 41°F to 113°F (ambient) |
Temperature (Metric) Operating | 5°C to 45°C (ambient) |
Temperature Probe Calibration | 1 point temperature offset calibration, 3 point LogR temperature calibration |
Temperature Range (English) | 22.0°F to 221.0°F |
Temperature Selection | Manual or automatic with ATC temperature probe, automatic with pH electrode using LogR mode |
Dimensions (L x W x H) | 28 x 24 x 10 cm (11 x 9.5 x 3.9 in.), modules add ≤ 2 cm (0.8 in.) L & H |
Weight (English) | 2.5 lb., modules add 0.5 lb. each |
Weight (Metric) | 1.2 kg, modules add 0.2 kg each |
Unit Size | Each |
Catalog Number | Specifications | Unit Size | Description | Includes | Price (USD) | Availability | Quantity | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
VSTAR80 | Each | Orion Versa Star Pro pH/LogR benchtop meter with stand | Versa Star Pro meter with pH/LogR module, electrode stand, 100-240V universal power adapter, computer cable | Price: 2,186.00 Your Price: | *** | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
VSTAR82 | Each | Orion Versa Star Pro pH/LogR benchtop meter difficult sample kit with ROSS Sure-Flow pH electrode and ATC probe | Versa Star Pro meter with pH/LogR module, 8172BNWP ROSS Sure-Flow glass-body pH electrode, 927007MD stainless steel ATC probe, 810199 pH buffer kit, 810007 ROSS fill solution, electrode stand, 100-240V universal power adapter, computer cable | Price: 2,634.00 Your Price: | *** | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
VSTAR83 | Each | Orion Versa Star Pro pH/LogR benchtop meter micro sample kit with TRIS-compatible ROSS micro pH electrode and ATC probe | Versa Star Pro meter with pH/LogR module, 8220BNWP ROSS Micro glass-body pH electrode, 927007MD stainless steel ATC probe, 810199 pH buffer kit, electrode stand, 100-240V universal power adapter, computer cable | Price: 2,683.00 Your Price: | *** | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
System Access Feature
Orion Versa Star Pro Meters offer a system access feature that is designed to help ensure data integrity by preventing undesired access to various meter functions including date/time setting, data log and calibration log. The System Access feature can be easily turned on or off as the needs of your lab change for ultimate flexibility in operation and ease-of-use. When enabled, the System Access feature allows assignment of a system administrator and up to ten user accounts with customizable access to instrument settings, measurement settings, calibrations and logs. Use the password protection to secure selected meter functions, while leaving other functions accessible for all users. The System Access feature allows you to customize meter access to meet your specific security and data reporting needs.
Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.