Restore™ PLUS Western Blot Stripping-Puffer
Restore™ PLUS Western Blot Stripping-Puffer
Thermo Scientific™

Restore™ PLUS Western Blot Stripping-Puffer

Thermo Scientific Restore PLUS Western Blot Stripping Buffer ist eine erweiterte Formel zum Entfernen gebundener primärer und sekundärer Antikörper vonWeitere Informationen
Have Questions?
Ansicht ändernbuttonViewtableView
KatalognummerMenge
4642830 ml
46430X44 x 500 ml
46430500 ml
Katalognummer 46428
Preis (EUR)
56,65
キャンペーン価格
66,00
Ersparnis 9,35 (14%)
Each
Zum Warenkorb hinzufügen
Menge:
30 ml
Großbestellung oder individuelle Größe anfordern
Preis (EUR)
56,65
キャンペーン価格
66,00
Ersparnis 9,35 (14%)
Each
Zum Warenkorb hinzufügen
Thermo Scientific Restore PLUS Western Blot Stripping Buffer ist eine erweiterte Formel zum Entfernen gebundener primärer und sekundärer Antikörper von Membranen, damit diese rehybridisiert und mit Chemolumineszenzsubstraten erneut ausgelesen werden können.

Merkmale von Restore PLUS Western Blot Stripping Buffer:

Gebrauchsfertig und anwenderfreundlich – Keine Verdünnung erforderlich; keine unangenehmen Gerüche; Lagerung bei Raumtemperatur
Kompatibel – Verwendung auf Nitrozellulose- und PVDF-Membranen, unabhängig davon ob noch nass oder bereits trocken; funktioniert mit praktisch jedem Blockierpuffer, Enzymkonjugat und Chemolumineszenzsubstrat
Kostengünstig – Sparen Sie wertvolle Zeit und Proben; Blots beim ersten Mal effektiv ablösen
Robust und dennoch schonend – Übertragene Proteine bleiben lebensfähig; eine Blot bis zu fünf Mal strippen
Flexibel — Ablösen und Rehybridisieren, um Antikörperkonzentrationen zu optimieren oder um ein neues Antigen mit verschiedenen Antikörpern nachzuweisen

Restore PLUS Buffer ist eine alternative Formulierung des ursprünglichen Thermo Scientific Restore Western Blot Stripping Buffer. Der Restore PLUS Stripping Buffer wurde für den Einsatz mit Antikörpern entwickelt, die schwer von Western Blots zu entfernen sind und längere Inkubationszeiten oder Inkubationstemperaturen von mehr als 22 °C mit schonenderen Formulierungen erfordern. Antikörper mit hoher Affinität können bei Raumtemperatur und ohne das Entfernen übertragener Proteine schnell und effektiv von Western Blots abgelöst („gestrippt“) werden, wodurch mehrere Rehybridisierungen des Ziels möglich sind.

Protokollzusammenfassung:
• Waschen Sie den Blot, um chemolumineszentes Substrat zu entfernen
• Blot in Restore Western Blot Stripping Buffer für 5 bis 15 Minuten bei Raumtemperatur inkubieren
(oder bei 37 °C bei Antikörpern mit hoher Affinität inkubieren)
• Blot entfernen und im Waschpuffer waschen
• Membran blockieren
• Auf eine ausreichende Entfernung von Antikörpern testen
• Anschließend das nächste Immunblotexperiment durchführen
For Research Use Only. Not for use in diagnostic procedures.
Specifications
NachweisverfahrenChemolumineszenz
Zur Verwendung mit (Anwendung)Western Blot
FormFlüssig
Membrane CompatibilityNitrozellulose, PVDF
ProduktlinieRestore
ProdukttypWestern-Blot-Stripping-Puffer
Menge30 ml
Unit SizeEach
Inhalt und Lagerung
Nach Erhalt bei Raumtemperatur lagern. Das Produkt wird bei Umgebungstemperatur versendet.

Häufig gestellte Fragen (FAQ)

How many times can I strip my blot using Restore or Restore Plus Western Blot Stripping Buffers ?

The stability of the attached (transferred and bound) protein will determine the number of times the membrane can be successfully re-probed after stripping. The protein may withstand stripping as many as four times or as few as one time.

Find additional tips, troubleshooting help, and resources within our Protein Electrophoresis and Western Blotting Support Center.

What is the proper wash buffer to use after stripping with Restore or Restore Plus Western Blot Stripping buffers?

Wash the membrane with the same buffer as was used between antibody probing steps during the Western blotting procedure.

Find additional tips, troubleshooting help, and resources within our Protein Electrophoresis and Western Blotting Support Center.

Can I strip membranes with Restore or Restore Plus Western Blot Stripping Buffer and reprobe for subsequent detection with fluorescent probes?

No. Although the fluorescent antibodies, like other antibodies, can be stripped with Restore Buffers, stripped membranes typically produce unacceptable background for subsequent fluorescent detection methods. We recommend Restore Fluorescent Western Blot Stripping Buffer, Cat. No. 62299 (20 mL) and Cat. No. 62300 (100 mL).

Note: Restore Fluorescent Western Blot Stripping Buffer is for use with low-fluorescence PVDF membrane (Cat. No. 22860) only.

Find additional tips, troubleshooting help, and resources within our Protein Electrophoresis and Western Blotting Support Center.

Will Restore and Restore Plus Western Blot Stripping Buffers remove biotin-bound avidin, streptavidin or NeutrAvidin Protein conjugates?

No. Restore and Restore Plus Buffers are not stringent enough to break the avidin-biotin interaction. A buffer capable of breaking this interaction would likely also damage the target protein, making it undetectable. However it may be possible to strip the complexed biotinylated primary antibody and streptavidin-HRP secondary antibody from the target protein on the membrane. Please also see Tech Tip: Strip and Reprobe Western Blots (https://assets.thermofisher.com/TFS-Assets/BID/Technical-Notes/strip-reprobe-western-blots-tech-tip.pdf).

Find additional tips, troubleshooting help, and resources within our Protein Electrophoresis and Western Blotting Support Center.

Will the Restore and Restore Plus Western Blot Stripping Buffers remove precipitating substrates?

No. The antibodies are removed but the substrate leaves a permanent precipitate on the membrane that cannot be removed. Restore and Restore Plus Buffers are designed for procedures using chemiluminescent substrates. Please note that this is not compatible with fluorescence supstrates as it will result in increased background. For fluorescent substrates please use our Restore Fluorescent Western Blot Stripping Buffer. Please also see Tech Tip: Strip and Reprobe Western Blots (https://assets.thermofisher.com/TFS-Assets/BID/Technical-Notes/strip-reprobe-western-blots-tech-tip.pdf).

Find additional tips, troubleshooting help, and resources within our Protein Electrophoresis and Western Blotting Support Center.